JSP P5310 Скачать руководство пользователя страница 2

- 2 -

Low-Cost Programmable Transmitters P5310, P5311 with LHP Communication

Contents

1. General instructions and information

1.1 Symbols used ................................................................................................................................................3

1.2 Safety cautions and warnings ........................................................................................................................3

1.3 Scope of delivery ...........................................................................................................................................3

1.4 Description of the delivery and packing .........................................................................................................3

1.5 Storage ..........................................................................................................................................................3

1.6 Installation and commissioning ......................................................................................................................3

1.7 Spare parts ....................................................................................................................................................3

1.8 Repairs ..........................................................................................................................................................3

1.9 Warranty .........................................................................................................................................................3

2. End of service and disposal

2.1 End of service ................................................................................................................................................3

2.2 Disposal .........................................................................................................................................................3

3. Product description

3.1 Application .....................................................................................................................................................4

3.2 Description .....................................................................................................................................................4

3.3 Dimensional drawings ....................................................................................................................................5

3.4 Block diagram ................................................................................................................................................5

4. Installation, operation and maintenance

4.1 Installation and commissioning ......................................................................................................................6

4.2 Description of setting and configuration using the communicator LHPWinCom ............................................7

4.3 Description of setting and configuration using a handheld configurator LHPConf or HARTConf ..................7

4.4 Operation and maintenance...........................................................................................................................7

5. Product specifications

5.1 Technical specifications..................................................................................................................................8

5.2 Supplementary parameters ...........................................................................................................................9

6. Tests, certificates and standards

6.1 Tests, certificates ...........................................................................................................................................9

6.2 Standards ......................................................................................................................................................9

6.3 Marking and type tag information ..................................................................................................................9

6.4 Limiting conditions of use of a transmitter in an intrinsically safe version (code EI1) ....................................9

6.5 Limiting conditions of use of a transmitter in version with code EN2 ...........................................................10

7. Ordering information

7.1 Ordering table ..............................................................................................................................................10

Contacts .............................................................................................................................................................11

Содержание P5310

Страница 1: ...www jsp sk This document applies to serial numbers 10090000 and higher One type of transmitter for all common resistance and thermocouple sensors Linearized output signal 4 to 20 mA Accuracy from 0 1...

Страница 2: ...4 Installation operation and maintenance 4 1 Installation and commissioning 6 4 2 Description of setting and configuration using the communicator LHPWinCom 7 4 3 Description of setting and configurati...

Страница 3: ...e cover and provided with an identification label with a mark of the output control The product must not be exposed to direct rain vibrations and shocks during transport 1 5 Storage The products shall...

Страница 4: ...minal block temperature or by the entered constant temperature The inner sensor guarantees maximum accuracy and stability of cold junction temperature measurement If required compensation using an ext...

Страница 5: ...5 Low Cost Programmable Transmitters P5310 P5311 with LHP Communication 3 3 Dimensional drawings Version P531x H1x Version P531x L1x 3 4 Block diagram...

Страница 6: ...ctrostatic charging Such case may be a metal temperature sensor head or a suitable metal installation box if it does not contain magnesium nor titanium During installation it is also necessary to resp...

Страница 7: ...the input quantity The fixed output mode can be closed by the program button or by disconnecting of the transmitter power supply Transmitters in version EI1 or EN2 Ex version can be set up using the c...

Страница 8: ...0 to 400 C IEC 584 1 thermocouple B 100 to 1800 C IEC 584 1 thermocouple E 200 to 950 C IEC 584 1 thermocouple L 200 to 900 C DIN 43710 thermocouple C 0 to 2300 C N I S T Monograph 175 range can be se...

Страница 9: ...esponding temperature 10 C Range 0 to 4000 Ohm 0 1 SR or 0 8 Ohm or corresponding temperature 10 C Range 15 to 70 mV 0 1 SR or 0 02 mV or corresponding temperature 10 C the greatest value is valid Lon...

Страница 10: ...RTMod Miniature HART modem with galvanic isolation USB RS232C Communication interface for to USB port of the PC PT1000A Compensation resistor Pt1000 30 to 150 C for external compensation of thermocoup...

Страница 11: ...JSP Industrial Controls JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Отзывы: