background image

©JRI 

 

III.

 

HOW TO USE 

a)

 

Stop 

When you receive the LoRa© Spy, it is stopped. It can neither transmit nor receive. 

b)

 

Turn-on 

 

 

 

 

 

 

When  you  turned  on  the  LoRa©  Spy  by  pressing  3  seconds  on  the  touch  button,  it  tries  to  connect  to  the 
Objenious Public Network (join request). If it receives an answer (join accept), then it measures and transmits 
its measurements via Objenious Network. And Status LED flashes regularly according to its status. If there is no 
answer from the Network, it will try to send another join request after a few seconds. 

When the LoRa© Spy is connected to a LoRa gateway, it sends a presence message immediately (about a few 
seconds).  Then  it  measures  the  temperature  and  sends  a  message  every  30  seconds.  The  LoRa©  Spy  send 
Unconfirmed  uplink  by  default,  a  short  press  on  the  touch  button  will  enforce  a  measurement  and  toogle 
between Confirmed and Unconfirmed uplink. 

c)

 

Turn-off 

 

 

 

 

 

 

 

Every time you turn it off, the LoRa© Spy will reconnect to the Objenious Public Network (another join request) 
at the next turn-on. 

d)

 

Touch button’s action 

 

Press time 

Mode  

 < 3" 

> 3’’ 

Turn-on 

 During 3’’ 

Measure 

 1’’        = OK 

 1’’        = Technical alarm 

 1’’        = On alarm 

 

     Stop 

 
 

Stop

   

 

     Stop 

  

 

e)

 

Entrance of test mode 

When the LoRa© Spy is turned on, you can send 0x01010101 on 224 Port form your gateway (downlink) to 
activate Test Mode. 

3’’ 

3’’ 

3’’ 