
3-11
3
3) Depth setting menu
How to open the depth menu
It opens by pushing the [DEPTH] key.
Refer to “Fig. 3.2.2, Fig. 3.2.3”.
How to close the depth menu
When the menu is closed, it closes pushing the [DEPTH]key again. Or, even if the lower menu
[display/end] is selected with cursor key, and the [ENT] key is pushed, it closes.
How to move to the lower hierarchy (submenu) of the depth menu
This procedure is the same as the above-mentioned "Standard menu".
How to move to the higher hierarchy (submenu) of the depth menu
This procedure is the same as the above-mentioned "Standard menu".
How to decide the item
This procedure is the same as the above-mentioned "Standard menu".
Depth menu list
Refer to “3.2 Menu Composition” or “12.1-(15)”, “12.1.1-(20)”.
4) Return of menu
The set value that is input with the menu screen and fixed is returned to former set value
([UNDO] key of keyboard).
[Common: Standard menu, Selection frame menu, Depth menu]
Even after the setting of the menu is fixed with the [ENT] key, it is possible to return it to a set value
before the menu is changed with the [UNDO] key before the menu is closed.
Ex.)
Current measurement layer and depth
setting: Numeric key input
Current measurement layer and depth
setting: Numeric key input
A layer
12
m
TOP
A layer
12
m
TOP
B layer
20 m
B layer
50
m
C layer
0
30 m
C layer
0
80
m
D layer
50
m
D layer
100
m
E layer
100
m Bottom Lock
E layer
150
m Bottom Lock
Menu Display
Display
End
Return
Menu Display
Display
End
Return
Help
≫
Push [ENT] key
Help
≫
Push [ENT] key
Before change
After change
Change
Setting
Value
1) Push [UNDO] key.
2) Undo menu is displayed.
3) Execution is selected from Undo
(discontinuance/execution), and push the [ENT] key.
4) It returns to the setting before it changes.
▼
▼
▼
▼
▼
▼
▼
▼
▼
▼
Fig. 3.2.3 [FISH] Screen
When the [FISH] screen is displayed, the
depth range setting menu of the [FISH]
screen is displayed.
Fig. 3.2.2 [CURR] Screen
When the current measurement data
(All screens except the [FISH] screen
correspond) is displayed, the depth
setting menu of the current
measurement layer in the A-E layer is
displayed.
Ex.: [FISH] 3 Screen
The depth range setting
menu of the [FISH] screen
is displayed.
DEPTH RANGE
Ex.: [CURR] 1 Screen
Circle Graph Display
The current
measurement depth of
the A-E layer is set.
Содержание JLN-650
Страница 2: ...ii...
Страница 18: ......
Страница 20: ......
Страница 21: ...1 1 1 Overview...
Страница 22: ...1 2...
Страница 28: ...1 8 Fig 1 4 1 NWZ 164 LCD Monitor Outline WARNING HIGH VOLTAGE DO NOT REMOVE THE COVER WARNING LABEL Unit mm...
Страница 29: ...1 9 1 Fig 1 4 2 NCH 603E Keyboard Outline Unit mm...
Страница 33: ...1 13 1 Fig 1 4 5 1 NKF 775 Transducer Outline...
Страница 34: ...1 14 Fig 1 4 5 2 NKF 780 Transducer Outline Unit mm BOW...
Страница 37: ...2 1 2 Name and Functions...
Страница 38: ...2 2...
Страница 60: ......
Страница 61: ...3 1 3 Operation Method...
Страница 62: ...3 2...
Страница 77: ...4 1 4 Operation...
Страница 78: ...4 2...
Страница 120: ......
Страница 121: ...5 1 5 Measurement Alarm...
Страница 122: ...5 2...
Страница 125: ...6 1 6 How to See Display...
Страница 126: ...6 2...
Страница 132: ......
Страница 133: ...7 1 7 Confirming the Operation of Equipment...
Страница 134: ...7 2...
Страница 145: ...8 1 8 Maintenance and Check...
Страница 146: ...8 2...
Страница 149: ...9 1 9 Trouble and After sales Service...
Страница 150: ...9 2...
Страница 153: ...9 5 9...
Страница 160: ...9 12...
Страница 161: ...10 1 10 10 Disposal...
Страница 162: ...10 2...
Страница 164: ......
Страница 165: ...11 1 11 Specifications...
Страница 166: ...11 2...
Страница 170: ......
Страница 171: ...12 1 12 Others...
Страница 172: ...12 2...
Страница 184: ...12 14 12 2 Connection Diagram JLN 650 Connection Diagram...
Страница 185: ...12 15 12 JLN 652 Connection Diagram...
Страница 186: ...12 16 12 3 Spare Parts List...
Страница 187: ...12 17 12 JLN 652 1 1 7ZXNA3002 JLN 652 1 1 7ZXNA3002...
Страница 188: ......
Страница 189: ......