![JRC AP-IFU Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/jrc/ap-ifu/ap-ifu_user-manual_2028199028.webp)
Table 3-2 AP-IFU Controls
Switch
Description
1 ETHER1
AUTO
(The shape of the switch
may be changed)
Sets the ETHER1 interface (100BASE full duplex/AUTO).
After changing the switch setting, you have to reboot the unit (power off and
back on) to enable the new setting.
AUTO: AUTO
100FULL: 100BASE full duplex (factory setting)
2 ETHER2
AUTO
(The shape of the switch
may be changed)
Sets the ETHER2 interface (100BASE full duplex/AUTO).
After changing the switch setting, you have to reboot the unit (power off and
back on) to enable the new setting.
AUTO: AUTO
100FULL: 100BASE full duplex (factory setting)
Table 3-3 Alarm Issuance and Clear Conditions
Item
Initial state
Issued when:
Cleared when:
The RFU-CPU detects LOCALM or
TRSELALM three times each for
more than 10msec.
The RFU-CPU detects no
LOCALM or TRSELALM
three times each for more
than 10msec.
LOCALM (local oscillator alarm)
occurs if the local oscillator lost
synchronization.
Synchronization is
recovered.
TRSELALM
(transmission/reception switchover
SW failure) occurs if the
transmission state continues for
more than 1sec.
Only by a reset.
1 RFU
failure
Cleared
IFU-CPU detects a RFU-IFU
communication error (monitoring
response).
IFU-CPU is cleared by a
single RFU-IFU
communication (monitoring
response).
Communication error among the
S-CPU, D-CPU and U-CPU.
No response to polling for 3sec
Cleared by a single
response.
2 IFU
failure
Cleared
L2SW setting failure
If setting failed four times (once for
transmission and 3 times for
retransmission)
No recovery
3 Communication
error
between RFU and IFU
Cleared
The S-CPU detects a S-RFU-CPU
communication error.
No response to polling four times
(once for transmission and 3 times
for retransmission)
Cleared by a single
response.
4 ETHER 1 link down
Issued
PHY link down 3 times each for
100msec.
Recovered from PHY link
down 3 times each for
100msec.
5 ETHER 2 link down
Issued
PHY link down 3 times each for
100msec.
Recovered from PHY link
down 3 times each for
100msec.