3-15
3.2.2 Operations and Indications
Figure 3-3 AP-IFU Operation and Indication Panel
Table 3-1 AP-IFU Indications
LED
State
indication
c
POWER
Lit green: Power on
Extinguished: Power off
d
ETHER 1
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 4)
e
ETHER 2
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 5)
f
IFU STATE
Lit red: IFU alarm (See Table 3-3, 2)
Flashing green: Normal (CPU running)
Flashing orange: During initialization
g
RFU ALARM
Lit red: RFU alarm (Cause: RFU failure (See Table 3-3, 1) or communication
error between the IFU and RFU (See Table 3-3, 3))
Extinguished: RFU alarm cleared
h
ETHER1 AUTO
Lit green: AUTO (ETHER1 AUTO switch set to AUTO)
Extinguished: 100BASE full duplex
i
ETHER2 AUTO
Lit green: AUTO
Extinguished: 100BASE full duplex
j
RST
Unit reset switch
制御盤LED部拡大図
26G‑2‑AP‑PWR
26G‑2‑AP‑CNT
POWER
ETHER
1
ETHER
2
IFU
STATE
RFU
ALARM
AUTO
100
FULL
AUTO
100
FULL
ETHER1 AUTO ETHER2 AUTO
①
②
③
④
⑤
⑥
⑦
⑧
Содержание AP-IFU
Страница 1: ...JUL 6226 MANUAL APRIL 13 2005 Version 1 4...
Страница 18: ...Figure 1 3 External View of the AP IFU External View of the AP IFU Generic nameplate Nameplate for this unit...
Страница 20: ...Figure 1 6 External View of the WT Adapter...
Страница 21: ...1 9 Figure 1 7 External View of the WT AC Adapter 120 or less 70 or less 30 or less...