Backlight for the buttons can be powered from internal or external 24VDC power supply. Power supply selection is made
with dip switches 5 and 6.
5.8.3 CTRL Output
Console is equipped with relay dry contact output control. It can be used for:
•
General system monitoring control. In monitored system Console supervises master System Unit. If it recognizes
a fault in the unit or in the transmission path to console, it gives general “System Fault” indication and activates the
relay control. Control is to be used in VAC, monitoring room etc. to indicate “fatal error”, of the system.
Note Control is recommended to connect between NC and COM to supervise the control cable itself.
•
Local speaker muting control. Speaker(s) near the Paging/Control Console are muted during paging to prevent the
acoustical feedback form speaker to the microphone.