    NXU-2A Operations Manual 

 

Interoperability Now! 

3-9

 

 

3.3.16

 

Command Port 

The port used by the NXU-2A for receiving commands via the telnet protocol or from a WAIS 
Controller.    The  value  defaults  to  23  and  under  normal  circumstances  should  not  need  to  be 
changed.  If necessary, the command port may be changed by using the CMDPORT command.  
Type CMDPORT <port  number>  and press  ENTER.   The port number  must range from 1 to 
65535 and must be different than the VoIP port. 

3.3.17

 

Input Level Boost +20db 

The receive input level may optionally be boosted by +20db in order to accommodate low level 
signal  sources.    Provisioning  via  the  web  interface  allows  selecting  either  “No  Boost”  or, 
“Boost +20db” in the ‘RX Boost Mode’ field. 

3.3.18

 

TX Delay 

Additional delay may be provided to the transmit audio path.  Via the web interface ‘TX Delay 
(mS)’ field, the user may introduce up to 10 seconds of delay, in specified in 1 mS increments.  
Upon  editing  the  field  with  numeric  data,  the  NXU-2A  will  round  to  the  nearest  100mS 
interval.  When additional delay is used, the PTT\ signal will be asserted prior to the delayed 
audio being presented, allowing LMR trunking systems to be accessed without audio loss. 

3.3.19

 

RX Delay 

Additional delay may be provided to the receive audio path.  Via the web interface ‘RX Delay 
(mS)’  field,  the  user  may  introduce  from  0  to  10  seconds  of  delay,  specified  in  1  mS 
increments.   Upon editing the field  with  numeric data, the NXU-2A  will round to  the nearest 
100mS  interval.    When  additional  delay  is  used,  the  received  audio  will  be  delayed  before 
being sent to the network. 

3.3.20

 

VMR 

Voice  Modulation  Recognition  has  been  added  to  allow  interfacing  with  radios  which  do  not 
provide a separate COR signal.  VMR provides a more robust method of ‘COR Sensing’ than 
VOX alone.  VMR mode may be selected via the web interface ‘COR Sense’ field pulldown 
menu.    When  VMR  mode  is  chosen,  the  hardware  COR  signal  is  ignored,  and  audio  content 
with the appropriate speech characteristics is allowed to simulate the COR signal.  

3.3.21

 

VOX and VMR Sensitivity Adjustments 

When either VOX or VMR COR sensing is selected, three levels of sensitivity adjustments are 
provided to  allow  greater flexibility.  Via the web interface, “Low” sensitivity  requires more 
signal content to recognize and simulate COR activity.  “High” sensitivity requires less signal 
content to recognize and simulate COR activity.  The default sensitivity is “Medium”. 

3.3.22

 

Restoring Factory Defaults 

The NXU-2A allows the user to restore the original factory default operating conditions.  This 
may be useful if the unit has been incorrectly configured, and it is necessary to return to a well-
defined  state.    To  restore  the  factory  default  conditions,  the  power  to  the  unit  needs  to  be 
removed  and  restored  while  rear  panel  switch  “SW1”  (

DEFAULTS

)  is  depressed.    When  the 

front panel  LED’s have blinked, the switch may be released, and the unit will be operational 
using the JPS factory default parameters.  The IP address will return to “

192.168.1.200

”, which 

will allow web configuration.  All other previously assigned user parameters will be lost during 
this process. 

Содержание NXU-2A

Страница 1: ...on and Operation Manual NXU 2A Network Extension Unit JPS Interoperability Solutions 5800 Departure Drive Raleigh NC 27616 919 790 1011 Email sales jpsinterop com support jpsinterop com www jpsinterop...

Страница 2: ...s likely to cause harmful interference in which case users will be required to correct the interference at their own expense CAUTION Changes or modifications to this equipment not expressly approved b...

Страница 3: ...t Point 2 8 2 8 3 Connection to Radio or Other Four Wire Device J7 2 8 2 8 4 Network Connection J3 2 8 2 8 5 Serial Port Connection J4 2 9 2 8 6 Connecting Equipment and Computers to an NXU 2A 2 9 3 C...

Страница 4: ...X Outputs 3 16 4 OPERATION 4 1 4 1 GENERAL 4 1 4 2 FRONT PANEL INDICATORS 4 1 4 2 1 Power LED 4 1 4 2 2 Link Active LED 4 1 4 2 3 Channel Active LED 4 1 4 2 4 Audio Input LED 4 1 4 3 REAR PANEL CONNEC...

Страница 5: ...U 2A SETUP SCREEN 3 12 FIGURE 3 3 NXU 2A TERMINAL SCREEN 3 13 FIGURE 3 4 NXU 2A HISTORY SCREEN 3 14 FIGURE 3 5 NETWORK CONFIGURATION SCREEN 3 15 FIGURE 4 1 NXU 2A CONNECTION MANAGEMENT SCREEN 4 4 FIGU...

Страница 6: ...Local Area Network A group of computers and associated devices that share a common communications line typically within a small geographic area PTT Push to talk A signal to a radio transmitter which c...

Страница 7: ...equirement for pilot tones and other in band signaling Facilitates centralized control of a communications network from a single computer 1 2 2 NXU 2A Description The NXU 2A is intended for use with r...

Страница 8: ...2A is a 10 100BASE T Ethernet device and each unit has a unique Ethernet address and an RJ 45 physical interface jack A 10 100BASE T device operates at either 10 or 100 Mbps and interconnects to an Et...

Страница 9: ...te audio console The transmit receive audio and PTT COR signals are transported digitally across the network and appear at the other end The network data transfer is transparent to the user and the op...

Страница 10: ...cuit Voltage 60 VDC Serial Interface Interface Type RS 232 Asynchronous Full Duplex Baud Rates 300 1200 2400 4800 9600 19200 38400 57600 115200 bps Connector DB 9 Male Standard PC AT DCE Pinout Networ...

Страница 11: ...080000 RS 232 Serial Cable 6 ft 1 0313 080515 Audio Crossover Adapter 1 7 Optional Equipment Not Supplied Table 1 3 Optional Equipment Not Supplied Description JPS P N Operation Maintenance Manual pri...

Страница 12: ...NXU 2A Operations Manual 1 6 Interoperability Now This Page Left Intentionally Blank...

Страница 13: ...odel and Serial Numbers Shipping Agency Date s of Shipment The JPS Customer Service Department can be reached by phone at 919 790 1011 by fax at 919 790 1456 Upon receipt of this information JPS will...

Страница 14: ...ubnet mask and if applicable the gateway address for the unit You may have to contact the network administrator for your organization to obtain this information NOTE Operation of the NXU 2A is not pos...

Страница 15: ...with other heat generating equipment the use of a rack blower is suggested to keep the cabinet interior temperature rise to a minimum NOTE If the NXU 2A is installed in a high RF environment such as r...

Страница 16: ...NXU 2A Operations Manual 2 4 Interoperability Now Figure 2 1 Outline Dimensions...

Страница 17: ...NXU 2A Operations Manual Interoperability Now 2 5 Figure 2 2 Control and Connector Locations...

Страница 18: ...nternal Configuration The illustration below shows the NXU 2A with its top cover and rear panel removed There is normally no reason to remove the top cover as the NXU 2A has no internal user serviceab...

Страница 19: ...uptible power system UPS If the overall site does not have UPS capability the NXU 2A should be plugged into a smaller UPS such as those used for personal computer systems 2 7 Installation Checklist Ta...

Страница 20: ...e using a cable specifically designed to connect an ACU 1000 to that radio The adapter makes the NXU 2A audio connector pinout match the one found on the ACU 1000 If you are wiring your own cable or i...

Страница 21: ...a crossover cable RS 232 serial devices are divided into two types Devices which provide control information are called DTE Data Terminal Equipment devices Devices which accept control information ar...

Страница 22: ...Cable RS232 Null Modem Cable RS232 Null Modem Cable RS232 Straight Through Cable RS232 Null Modem Cable DTE Device DTE Device DTE Device DCE Device DCE Device DCE Device COMP NXU 2 NXU 2 ACU 1000 J4...

Страница 23: ...he above network parameters are compatible with your network then you may attach the NXU 2A to your network and use your web browser or telnet client to configure the NXU 2A as outlined in Section 3 6...

Страница 24: ...on 3 5 2 3 3 1 Configuration Using an RS 232 Terminal Program A terminal program is needed to communicate with the NXU 2A for initial configuration A suitable Windows terminal program MTTTY EXE is inc...

Страница 25: ...our terminal program and they appear on the screen the NXU 2A is already in the COMMAND Mode Configuration Mode Command Set Type HELP and press the ENTER key The NXU 2A should respond with NXU 2A Comm...

Страница 26: ...the serial port data bits DISC Break this client s current connection DUPLEX 0 1 Select either full duplex 0 or half duplex 1 for audio ECHO ON OFF Enables disables character echo to console GATEIP i...

Страница 27: ...ld type MYIP 192 168 1 1 and press ENTER 3 3 4 Setting Unit Subnet Mask and Gateway Address Now set your subnet mask using the SUBNET command If you are using a gateway set the gateway address the add...

Страница 28: ...nd allows you to select the polarity of the COR input If a COR output signal is not available you may select VOX Voice Operated Switching VOX operation uses the detection of an audio signal from your...

Страница 29: ...g and vice versa Consider what can happen when the switch out of the TX mode causes a momentary active COR output Radio 1 COR becomes deactivated so the Radio 2 switches out of the TX mode and activat...

Страница 30: ...est of the ADPCM compression types 5 PCM 64Kbps Suitable for voice or tone signaling Offers the highest quality of all compression methods but provides the least compression You should use this method...

Страница 31: ...rest 100mS interval When additional delay is used the received audio will be delayed before being sent to the network 3 3 20 VMR Voice Modulation Recognition has been added to allow interfacing with r...

Страница 32: ...ocess agent is enabled and running but may be disabled by changing the SECURITY Setting see section on SECURITY The Management Information Database MIB associated with the NXU 2A may be obtained by co...

Страница 33: ...nsists of a multicast UDP channel for VoIP and status bit traffic No serial traffic is exchanged It can be used whenever more than two units wish to hear each other s audio The NXU 2A communications m...

Страница 34: ...ration Using the NXU 2A Setup Utility Included with the NXU 2A is a CD containing a program called NXU 2 Setup Utility This program which runs under Windows 95 98 NT 2000 or XP can be copied to the us...

Страница 35: ...nfiguration information in the NXU 2A The NXU 2A will restart and the new settings will then be in effect The NXU 2A Setup Utility allows the user to see the actual commands being sent to and received...

Страница 36: ...below To add the current unit to the configuration history type a name for the unit into the box beside the Add Current button and click the button The NXU 2A will be added to the list of units shown...

Страница 37: ...on 3 3 except that there is no need to type to enter command mode The telnet connection to the NXU 2A will automatically disconnect after two minutes of no activity or LOGOUT may be typed to disconnec...

Страница 38: ...sible from the rear panel This output provides a 0 dBm nominal level 15 dBm clipping into a 600 ohm load The audio output will supply signal levels from 30 to 11 dBm 3 7 4 COR Input The COR input to t...

Страница 39: ...e an active VoIP connection or the connection has been lost 4 2 3 Channel Active LED This green LED is lit whenever COR is active This also indicates that the NXU 2A is sending audio data across the I...

Страница 40: ...an AC voltmeter to the test point TP1 on the real panel and adjusting the IN LVL control for an average audio level of about 0 2V or 12dBm 4 4 3 COR Input Description The COR input on J7 controls the...

Страница 41: ...lly the NXU 2A client automatically connects to the preprogrammed NXU 2A server when power is applied The user may also manually control the connection state of the NXU 2A client This can be done via...

Страница 42: ...ontrol The NXU 2A client connection may be managed by browsing to the NXU 2A client IP address and selecting the Connection Management menu option The user may then issue connect or disconnect command...

Страница 43: ...example setting the security level to 136 128 8 disables both telnet and HTTP access Setting security to 96 64 32 allows the connection status to be monitored by HTTP but no configuration or connecti...

Страница 44: ...Network Password Dialog In order to access the NXU 2A you must enter the password that was previously programmed using the PASS command The User Name is not required you may enter anything or nothing...

Страница 45: ...ke sure you wait at least 5 seconds and then type three plus signs within 1 second Settings made in Command Mode do not appear to take effect You must issue a SAVE command after making changes in orde...

Страница 46: ...VE indicator is on continuously Verify that the COR polarity is programmed properly See section 3 3 8 If NXU 2A is attached to a radio COR line make sure the radio squelch is set properly Audio has pa...

Страница 47: ...e TCP overhead Can I use the NXU 2A on a dialup connection No The NXU 2A s network connection is via Ethernet Most dialup telephone line modems only provide RS 232 connections but even if an Ethernet...

Страница 48: ...empt to close the IP connection which may take several seconds Then it has to open a new connection This process may take 30 to 45 seconds depending on your network What is the difference between a st...

Страница 49: ...ausing network errors The extreme case would be if an NXU 2A is programmed to have the same IP address as an existing computer on the same network This would likely render that computer unusable for n...

Страница 50: ...h it between the single public IP address it holds and the private IP addresses used by devices on its network This means that no computers behind the NAT router are directly accessible from outside t...

Страница 51: ...gnal into a digital format There are times when the user may want or need higher voice quality or transparency to certain kinds of signaling tones The VOCODER command allows the selection of different...

Страница 52: ...en type three plus signs and nothing else If you type more than three plus signs the procedure won t work Wait a few seconds and try again In addition the three plus signs must be typed within a one s...

Страница 53: ...area of memory with the unit s DSP processor allowing data to be exchanged between the two processors quickly and easily When the network processor sees the unit s COR input line go active it collect...

Страница 54: ...NXU 2A Operations Manual 7 2 Interoperability Now This Page Left Intentionally Blank...

Страница 55: ...6 DTE Versus DCE Serial Cables 2 10 Duplex Setting 3 6 E Equipment and Accessories Supplied 1 5 Ethernet MAC Address 3 8 F Factory Defaults 3 9 Front Panel 4 1 G General Information 1 1 Glossary 1 6 I...

Страница 56: ...t Settings 3 7 Setting Unit IP Address 3 5 Setup Utility 3 2 Specifications 1 4 T TCP 1 6 Telnet Control 4 3 Theory Of Operation 7 1 Troubleshooting 5 1 TX Delay 3 9 U UDP 1 6 Unpacking and Inspection...

Отзывы: