www.jps.com.tw
40
9.2 EGEAR Mode:Standard Pulse Command Parameter List
EGEAR(Standard Pulse Command ) Group < Refer to chapter -14.3>
No.
Name
Default
Min.
Max.
Unit
Type
*W
009 CT4 Counter (Pulse Command X/Y input)
0
0
65535
count
M
1
036 EGEAR(STD) / PRT(Special) Mode Selection
0
0
1
FR/W;R
1
037 E-GEAR Mul-0 (EGEAR Mode)
10000
0
50000
R/W
1
038 E-GEAR Div-0 (EGEAR Mode)
10000
0
50000
R/W;R
1
039 E-GEAR Mul-1(EGEAR Mode)
10000
0
50000
R/W
1
054 E-GEAR Mul-2(EGEAR Mode)
10000
0
50000
R/W
1
055 E-GEAR Mul-3(EGEAR Mode)
10000
0
50000
R/W
1
110 E-GEAR X/Y Input Pulse Input Type
0
0
2
R/W;R
1
209 E-GEAR JOG Rpm( EGEAR Mode)
60
0
3000
rpm
R/W
1
210 E-GEAR Maximum Speed Limit
1000
0
3000
rpm
R/W
1
211 E-GEAR Ramp Rate
100
0
10000 ms/Krpm
R/W
1
212 PRT High Gain Lock Time
500
0
1000
ms
R/W
1