JP Fluid Control ST-SB Series Скачать руководство пользователя страница 4

JP FLUID CONTROL

 

MANUAL-ST-SB-EN v1.2                                                              www.jpfluidcontrol.com                                                                                   4 

ST-SB SERIES 

SOLENOID VALVES 

1.2.

 

Installation 

 Clean fluids and gases 

The  solenoid  valve  can  be  used  in  combination  with  clean  liquids  or 
gases. Check if there is any dirt in the piping or valve before installing.  
It is recommended to install a filter (500 µm) before the solenoid valve. 

Mounting the valve 

Be  aware  of  the  direction  of  flow  of  the  medium  when  installing  the 
valve. Solenoid valves with an arrow on the housing must be connected 
in the indicated direction. The pipes on both sides of the valve must be 
securely  fastened.  Use  a  wrench  for  both  valve  and  pipe  while 
tightening to prevent unnecessary stresses in the system. The solenoid 
valve must be fixed via the provided connection points. Only exert force 
at the designated areas on the body such as the hexagon; never to the 
coil or armature. Avoid vibration in the pipes. Use a suitable sealant for 
threaded connections  of the solenoid valve.  Avoid the entry  of thread 
sealing  material  in  the  valve,  this  can  lead  to  malfunctioning  of  the 
valve. 

Position 

It  is  recommended  to  install  the  solenoid  in  vertical  position  with  the 
coil  facing  upwards.  This  reduces  the  probability  of  the  collection  of 
debris in the solenoid valve. When the solenoid valve is mounted at an 
angle,  it  is  recommended  to  deviate  maximally  90°  from  the  vertical 
position. 
 

 

Maximum angle 90°. 

IN

O

U

T

 

Check the flow direction with the help of the indications on the valve 

body. 

 

Only exert force at the designated faces,  never at the coil or armature. 

Installation of the coil 

► 

Make  sure  the  coil  is  labeled  with  the  valve  characteristics.  The 
device can be damaged by the use of unsuitable tools. 

► 

The  temperature  of  the  coil  increases  during  use,  this  is  normal. 
Overheating  will  cause  smoke  and  a  burning  smell.  In  this  case, 
the power supply must be shut down immediately. 

► 

The  coils  can  be  rotated  if  the  coil  nut  is  loosened.  After  the 
determination of the correct position, the nut should be fastened 
with a torque of 5Nm. 

 

 

 

 

Installation of the cable plug 

► 

Always  connect  the  ground  (3),  which  is  provided  with  a 
residual  current  device  at  voltages  above  50V.  Never  use 
liquid  or gas piping for grounding electrical equipment. The 
power  supply  is  connected  to  terminals  (1)  and  (2).  The 
polarity does not matter. 

► 

Verify the voltage and frequency before connecting the coil.   

► 

When mounting the connector, make sure that no moisture 
can ingress  between  the coil and connector.  The connector 
screws should be fastened with a torque of 0.5Nm. 

Connecting the power supply 

► 

Never connect  power to  the coil when it is not attached  to 
the solenoid valve! The coil may burn out. 

► 

Only connect power if you are sure that there is no pressure 
in the system and no hazardous situations can occur. 
 

Содержание ST-SB Series

Страница 1: ...t S Position Normally open B Body Material Brass B SS 316 S Seal Media Temperature NBR N 10 80 C EPDM E 30 130 C FKM F 10 120 C Thread BSPP NPT N Ambient Temperature Max 50 C Min Press Difference 0 bar Max Pressure 16 10 bar AC DC Coil series CS2 Voltage 380V AC 50Hz 380AC 230V AC 50 60Hz 230AC 120V AC 50Hz 120AC 24V AC 50 60Hz 024AC 24V DC 024DC 12V DC 012DC Response Time 50 ms 400 ms Open Close ...

Страница 2: ... for aggressive media and corrosive media like seawater Diaphragm The ST SB series is available with several materials In the following table a concise overview is presented of compatible media Depending on the application the correct diaphragm should be selected Diaphragm Temperature Allowed media Not allowed FKM 10 C 120 C Most fuels and oils cold water detergents compressed air Glycol based bra...

Страница 3: ...indicated on the product and or in the technical documentation The temperature of a solenoid valve coil can rise during operation this is normal Overheating will cause smoke and a burning smell In this case the power supply must immediately be disconnected Warning a valve opens and closes quickly Improper use can cause pressure transients fluid hammer in the pipes with possible damage as a consequ...

Страница 4: ... is mounted at an angle it is recommended to deviate maximally 90 from the vertical position Maximum angle 90 IN OUT Check the flow direction with the help of the indications on the valve body Only exert force at the designated faces never at the coil or armature Installation of the coil Make sure the coil is labeled with the valve characteristics The device can be damaged by the use of unsuitable...

Страница 5: ... E REV EPDM ST SB F REV FKM ST SB SN REV NBR Stainless Steel orifice 9 mm ST SB SE REV EPDM ST SB SF REV FKM The product code of the coil is as follows Product code Voltage CS2 380AC 380V AC 50Hz CS2 230AC 230V AC 50Hz CS2 120AC 120V AC 60Hz CS2 024AC 24V AC 50Hz CS2 024DC 24V DC CS2 012DC 12V DC Follow the drawing in 1 7 for the correct assembly of the solenoid valve 5 DISPOSAL The removal of the...

Отзывы: