JP Fluid Control ST-SB Series Скачать руководство пользователя страница 2

JP FLUID CONTROL

 

MANUAL-ST-SB-EN v1.2                                                              www.jpfluidcontrol.com                                                                                   2 

ST-SB SERIES 

SOLENOID VALVES 

 

 

 

 

1.

 

TECHNICAL SPECIFICATIONS 

1.1.

 

Principle of operation 

A solenoid valve is a valve for neutral, clean liquids and gases, which is 
electrically controlled with the aid  of a solenoid.   2/2 way means that 
the  valve  has  two  ports  (input  /  output)  and  two  positions  (closed  / 
open).  The  valve  is  normally  open,  this  means  the  valve  closes  when 
voltage is applied. 
 
Semi-direct  operated  solenoid  valves  combine  the  properties  of  both 
direct and indirect operated solenoid valves

The force that is required 

to  open  and  close  the  diaphragm  is  supplied  by  both  the  solenoid 
plunger  as  well  as  the  pressure  of  the  medium.  This  allows  them  to 
work  from  a  zero  bar  pressure  differential.  Furthermore,  they  can 
control a high flow rate with a relatively small solenoid core. They  can 
be used in only one flow direction. This type of solenoid valves is used 
in  systems  that  require  a  reasonable  flow  rate,  while  the  pressure 
difference  between  input  and  output  is  low  or  unknown.  Semi-direct 
operated  solenoid  valves  open  slower  than  direct  operated  solenoid 
valves, but they are suitable for higher flow rates. 

1.2.

 

Area of application 

Body material 

The ST-SB series is available with a brass  or stainless steel body material. 
Depending on the application, the right material should be selected. 

 

Body material

 

Allowed media

 

Brass (ASTM #37800) 

Neutral and non-corrosive media. 

Stainless Steel (S316) 

Suitable  for  aggressive  media  and 
corrosive media like seawater. 

Diaphragm 

The ST-SB series is available with several materials. In the following table a 
concise  overview  is  presented  of  compatible  media.  Depending  on  the 
application the correct diaphragm should be selected.  

Diaphragm 

 

Temperature

 

Allowed media

 

Not allowed 

FKM 

-10°C.120°C 

Most fuels and 
oils, cold water, 
detergents, 
compressed air.  

Glycol-based 
brake fluids, 
ammonia gas, hot 
water and steam, 
low molecular 
weight organic 
acids (such as 
acetic acid). 

EPDM 

-30°C.130°C 

Water and 
steam, alcohol.   

Oils, fats, fuels, 
solvents. 

NBR 

-10°C.80°C 

Neutral media, 
like air, cold 
water, hydraulic 
oil. 

Fuels, strong 
acids, brake fluid. 

1.3.

 

Flow chart 

In the flow chart, the flow of water from 20°C is shown as a function of 
the  positive  pressure  difference  across  the  valve.  The  flow  rate  is 
expressed in liters per minute and the pressure in bar. The graph shows 
different  pipe  diameters.  The  stainless  steel  valves  (SS)  of  the  ST-SB 
series have a lower flow rate due to a smaller orifice.   
 

 

1.4.

 

Duty Cycle 

The  solenoid  valve  is  suitable  for  continuous  use.  High  switching 
frequencies and high pressures can reduce the lifespan. 

1.5.

 

Compliance 

The  coils  are  CE  marked  and  comply  with  the  LVD  Directive 
(2006/95/EC)  and  Directive  (2004/108/EC),  provided  that  the  cables 
and connectors are properly connected. 

1.6.

 

Type label 

The coil properties are displayed on a label on the coil. A second label is 
provided with the valve  that shows all relevant valve  parameters. This 
label must be attached to the other side of the coil.  In the figure below, 
an example is shown.

 

 

10

100

0.5

2.5

4.5

6.5

8.5

10.5

12.5

14.5

D

e

b

iet 

w

a

te

(l/

min

)

dp (bar)

1/4"

1/2"

3/8"

Stainless

Содержание ST-SB Series

Страница 1: ...t S Position Normally open B Body Material Brass B SS 316 S Seal Media Temperature NBR N 10 80 C EPDM E 30 130 C FKM F 10 120 C Thread BSPP NPT N Ambient Temperature Max 50 C Min Press Difference 0 bar Max Pressure 16 10 bar AC DC Coil series CS2 Voltage 380V AC 50Hz 380AC 230V AC 50 60Hz 230AC 120V AC 50Hz 120AC 24V AC 50 60Hz 024AC 24V DC 024DC 12V DC 012DC Response Time 50 ms 400 ms Open Close ...

Страница 2: ... for aggressive media and corrosive media like seawater Diaphragm The ST SB series is available with several materials In the following table a concise overview is presented of compatible media Depending on the application the correct diaphragm should be selected Diaphragm Temperature Allowed media Not allowed FKM 10 C 120 C Most fuels and oils cold water detergents compressed air Glycol based bra...

Страница 3: ...indicated on the product and or in the technical documentation The temperature of a solenoid valve coil can rise during operation this is normal Overheating will cause smoke and a burning smell In this case the power supply must immediately be disconnected Warning a valve opens and closes quickly Improper use can cause pressure transients fluid hammer in the pipes with possible damage as a consequ...

Страница 4: ... is mounted at an angle it is recommended to deviate maximally 90 from the vertical position Maximum angle 90 IN OUT Check the flow direction with the help of the indications on the valve body Only exert force at the designated faces never at the coil or armature Installation of the coil Make sure the coil is labeled with the valve characteristics The device can be damaged by the use of unsuitable...

Страница 5: ... E REV EPDM ST SB F REV FKM ST SB SN REV NBR Stainless Steel orifice 9 mm ST SB SE REV EPDM ST SB SF REV FKM The product code of the coil is as follows Product code Voltage CS2 380AC 380V AC 50Hz CS2 230AC 230V AC 50Hz CS2 120AC 120V AC 60Hz CS2 024AC 24V AC 50Hz CS2 024DC 24V DC CS2 012DC 12V DC Follow the drawing in 1 7 for the correct assembly of the solenoid valve 5 DISPOSAL The removal of the...

Отзывы: