background image

SL600AC SLIDING GATE OPERATOR 

                                                                                       

10 

ON

OFF

     L

   

N

SPE

E

D

 G

N

VC

C

CAP

MOT2

MOT1

COM

MOT

MOT

8

12

11
10

9

7

6

5

4

1

23

PE

LA
M

P

13

PE

L

SW1

T2

9

7

RL

2

RL1

VR2

VR1

6
5

10

1

3

12

2

OC2

OC1

F3

F2

F1

C20

C19

C22

J3

J6

J1

POWER

LEARN

VR4

VR3

S1

U3

U2

VDR1

Q3

J2

HAL

L

U1

J5

X1

J4

POWER

MOTOR

Caution light

Protect Earth

Capacitor

Extral button
switch

O/S/C switch

Pedestrian switch

Infared sensor

Loop detector

Limit
swtich

+12VDC

GND/COM

COM

COM

Learn button

Open limit

Close limit

                                                           

Fig.8 

Wiring notes of control board 

a.  Power Input (terminal J3): PE (Earth),L (Live),N (Neutral). 

SL600AC: AC220V 
SL600ACU:AC110V 

b.  Caution light: connect caution light wire to L and N of 

LAMP(terminal J4) 

SL600AC: AC220V   

SL600AC SLIDING GATE OPERATOR 

                                                                                       

11

SL600ACU: AC110V 

c.  Output power supply: 12VDC(7 of J5), COM (9 of J5), I.R. (8 of 

J5 is N.C Infrared) 

If the infrared beam is interrupted during closing, the gate will reverse 
and open immediately. The product is not factory equipped with an 
infrared device; the infrared output signal must be N.C. 
 

From four-terminal

to the receiver

COM

OUT

RX Receiver connecting

JUMP

NC OR NO

NC
NO

Form two-terminal to the emitter

12--24V AC/ DC

TX Emitter connecting

power supply

7

9

8

Control board

Terminal J5

Fig.9 infrared 

Schematic diagram   

 

d. Three-button switch / single-button switch (keypad): The 

SL600AC is equipped with interfaces for three-button switch and 
single-button switch (keypad).   
To install the keypad attach one lead of your keypad to ‘5’ of 

terminal J2 and the other to the ‘4(COM)’. The keypad will 
function in single channel mode. 

For three-button switch installation, use the terminals for 

multi-channel mode. Connect open wire of external button switch 
to ‘1 (OPEN)’ of terminal J2, connect close wire of switch to ‘2 
(CLOSE)’, connect stop wire of switch to ‘3(STOP)’, connect 
common wire of switch to ‘4(COM)’. 

         

Содержание SL600AC

Страница 1: ...urposes 2 Important safety information Carefully read and follow all safety precautions and warning before attempting to install and use this automatic gate operator z The gate operator should be inst...

Страница 2: ...0ACU Power supply 220V 50Hz 110V 60Hz Motor speed 55rpm 66rpm Rated output power of motor 180W Remote control operating distance 30m Frequency 433 92mHz Remote control mode Single button Output shaft...

Страница 3: ...d should be approximately 450mm x 300mm x 200mm deep in order to providing for adequate weight and structure to insure proper stable installation Anchors see Fig 2 You can use anchor bolts anchors was...

Страница 4: ...s are used to control the position of the gate SL600AC SLIDING GATE OPERATOR 7 z Release the gear with the key and push the sliding gate manually to pre determine the position fix the block to the rac...

Страница 5: ...z Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the release bar will be damaged z Open and close the gate...

Страница 6: ...Infrared If the infrared beam is interrupted during closing the gate will reverse and open immediately The product is not factory equipped with an infrared device the infrared output signal must be N...

Страница 7: ...PE Protect Earth C and C capacitor If the door move direction is wrong please change the MOT1 and MOT2 of motor and change the block of SL600AC SLIDING GATE OPERATOR 13 limit Magnetic limit switch Mot...

Страница 8: ...emote Pedestrian button After you learn the transmitter you press the remote button 4 the door will open 1 meter when the door is closed z You can program learn button 1 button 2 and button 3 individu...

Страница 9: ...When the 3 OFF and the 4 is ON auto close time is near 12 Sec when the 3 ON and the 4 is OFF auto close time is near 24 sec when the 3 and the 4 is all in ON position the auto close time is near 36 s...

Страница 10: ...120 C and switch on the motor automatically when the temperature is lower than 85 C 5 C 9 LED indicate a LED of Power indicated the input power b LED of LEARN indicated the transmitter learn status c...

Страница 11: ...mote transmitter does not work 1 Battery level may be low 2 Transmitter code is lost 1 Replace the battery inside the transmitter 2 Reprogram the transmitter The transmitter operating distance is too...

Отзывы: