Unit Operation 

Unit Operation 

Unit Operation 

Applying the Arm Cuff

1.  Firmly insert air plug into opening located on behind side of monitor unit.  

2.  With sticky nylon section facing outward, insert end of cuff underneath metal ring 

     of cuff  

3.  Fasten cuff about 

above the elbow joint.  For best results apply cuff to 

     bare arm and keep level with heart while testing

.

1-2cm (0.4-0.8'') 

.

2. Time Format setting
     Press 

 again to set the time fornat setting mode.

     Set the time format by adjusting the  MEM  button. EU means European Time US 
     means U.S Time.

"GROUP1" button or "GROUP2" button

"

"

6.  Saved Settings

4.Voice Setting
Press "GROUP1" button or "GROUP2" button to enter voice setting mode. Set voice format 
ON or OFF by pressing the "MEM" button.

5.Volume Setting
Press "GROUP1" button or "GROUP2" button to enter volume setting mode. Set the voice 
volume by adjusting the "MEM" button . There are six volume levels.

     While in any setting mode, press " START/STOP " button to turn the unit off.  All 
     information will be saved.  

Note:  If unit is left on and not in use for 3 minutes, it will automatically save all information 

            and shut off.

Unit Operation 

System Settings

With power off, press "GROUP1" button or 

 to activate System Settings.  

The Memory Group icon flashes.

"GROUP2" button

11

3.Unit Setting
Press 

 to enter unit setting mode. Set format 

by pressing the "MEM" button.

"GROUP1" button or "GROUP2" button

1.  Time/Date setting
     Press 

 again to set the Time/Date mode. Set the year 

    first by adjusting  the 

MEM

 button.

     Press 

 again to confirm current month. Continue 

     setting the date, hour  and minute in the same way. Every time the 

SET

 button is pressed, 

     it will lock in your selection and continue in succession ( month, day, hour, minute,
     12/24 hours)

"GROUP1" button or "GROUP2" button

"GROUP1" button or "GROUP2" button

AM

AM

mmHg 

KPa

Содержание DBP-6281B

Страница 1: ...peration 1 Do not drop the unit Protect it from sudden jars or shocks 2 Do not insert foreign objects into any openings 3 Do not attempt to disassemble the unit 4 Do not crush the pressure cuff 5 If the unit has been stored at temperatures below 0 oC leave it in a warm place for about 15 minutes before using it Otherwise the cuff may not inflate properly 6 If the unit has been stored at temperatur...

Страница 2: ...ce or helicopter 30 Contains small parts that may cause a chocking hazard if swallowed by infants 31 Please align the polarities of each battery with the ve and ve signs imprinted on the battery housing when you replace the batteries 32 Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation If such use is necessary this equ...

Страница 3: ...k Start 1 Install batteries 2 Insert cuff air plug into the behind side of monitor unit See Figure B See Figure A 3 Remove thick clothing from the arm area 4 Rest for several minutes prior to testing Sit down in a quietplace comfortably back and arm support on a desk or table withyour legs uncrossed your arm resting on a firm and your feet flat on the floor See Figure C 5 Apply cuff to your left a...

Страница 4: ... enter volume setting mode Set the voice volume by adjusting the MEM button There are six volume levels While in any setting mode press START STOP button to turn the unit off All information will be saved Note If unit is left on and not in use for 3 minutes it will automatically save all information and shut off Unit Operation System Settings With power off press GROUP1 button or to activate Syste...

Страница 5: ...ldest test result in memory can be viewed by pressing and holding the MEM button Upon activating test results you can press the MEM button to scroll through all test results stored in memory To check the average results from other groups please press corresponding GROUP1 button or GROUP2 button With power off press the MEM button to activate screen display After the unit performs a self diagnosis ...

Страница 6: ...2483 5 MHz Modulation GFSK Antenna gain 0 5dBi Troubleshooting Problem Solution displayed Connection failure Data is not being transmitted Cuff is too tight or not properly positioned on the arm Firmly reposition cuff approximately above the elbow joint See Page 12 1 2cm 1 2 Inaccurate test results due to body movement or monitor movement Sit in a relaxed position with arm placed near heart Avoid ...

Страница 7: ...essure varies throughout the course of a day Many factors including diet stress cuff placement etc may affect an individual s blood pressure Q Should I apply the cuff to the left or right arm What is the difference A Either arm can be used when testing however when comparing results the same arm should be used Testing on your left arm may provide more accurate results as it is located closer to yo...

Страница 8: ...rating Environment Automatic Pressurization LCD Digital Display Size 87 5mm X 85mm 3 44 x 3 34 Humidity Temperature 10 40 50 104 15 93 RH Storage Environment Humidity Classification Ingress Protection rating Battery Shelf life Battery Storage Temperature Temperature Internal Powered Equipment Type BF Cuff is the Applied Part IP 20 Indoor Used Only 60 months 25 55 13 131 25 55 13 131 Measurement Ra...

Страница 9: ...al environment Group 1 class B Table 2 continued Guidance and declaration of manufacturer electromagnetic immunity The device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environm ent Electromagnetic environment guidance Compliance level IEC 60601 test level IMMUNITY test Electromagnetic Compa...

Страница 10: ...e use and are non invasive blood pressure measurement systems designed to measure the systolic and diastolic blood pressure and pulse rate of adolescents and adults individual by using a non invasive technique which is a well known technique in the market called the oscillometric method it can measure the systolic blood pressure diastolic blood pressure and pulse rated on up arm and the device is ...

Отзывы: