5. MEASURING AND COUNTING FUNCTION

Press the  

    button and after that the multifunctional button

 

in the measuring mode to switch between the measuring function and the 

counting function.

It can be measured the input frequency, period, positive pulse width, duty 

cycle and other parameters. The measuring frequency range is between 1 

Hz and 100 MHz. The measuring signal amplitude range is between 2 Vpp 

and 20 Vpp. The input interface is ext. IN.

Coupling settings:

Press the multifunctional button 

 

to change between the AC and 

the DC mode.

Gate time settings:

Press the multifunctional button    

to set the gate time (0.01 - 10 S). 

Move the cursor with the arrow keys to the value which should be edited. 

Use the rotary button to adjust the value. 

Measuring mode: 

Press the multifunctional button 

 

 to change between the coun-

ting frequency and the counting period.

Measurement parameters:

 

Frequency, period, positive pulse width, negative pulse width, duty cycle

 

After you have set all parameters, you can use the multifunctional button

to start the counting function. The multifunctional button 

can stop the function.

6. MODULATION MODE

Press the button 

 

to start the modulation mode. Press the 

multifunctional button 

 

 to switch between the sweep function 

(channel CH1 / CH2), the pulse function (channel CH1) and the burst func-

tion (channel CH1). 

Sweep function:

You can set any starting and ending frequency of the signal generator. The 

possible time is between 0.1 and 999.9 s.

In the sweep mode, press the multifunctional buttons 

 to 

set the starting and ending frequency, as well as time, direction and mode. 

After selecting the respective setting, the arrow keys and the rotary button 

can be used for adjustment. 

MEAS

MOD

FUNC

COUP

GATE

MODE

FUNC

Содержание JDS6600

Страница 1: ...to 60 MHz in different waveforms and offers an outstanding quality with its frequency counter The control panel with its buttons is very intuitive Further the Menu can be displayed in German English and French language FURTHER SPECIFICATIONS Signal waveforms Lorentz pulse pulse half wave noise exponential rise fall CMOS a m m Frequency range sine square triangle PWM CMOS TTL arbitrary 0 60 MHz 0 1...

Страница 2: ...GENERAL INFORMATION Dear customer thank you for purchasing our product In the following we have listed what you should consider during commissioning Should you encounter any unexpected problems during use please do not hesitate to contact us ...

Страница 3: ... PC connection CH1 parameter CH2 parameter waveform display status of output channel menu bar difference of phase between CH1 and CH2 2 4 TFT LCD function keys short cuts rotary switch Output Input on off switch TTL interface for PC connection ...

Страница 4: ...e waveforms and the presettings Use the multifunctional button 1 to highlight the frequency para meter Then use the arrow keys to move the cursor to the value which should be edited Press the rotary button to edit the according value Hold down the multifunctional button to change the unit μHz mHz Hz KHz MHz Configuration of wave form Configuration of measuring mode Activation of the modulation mod...

Страница 5: ...e multifunctional button to change between the coun ting frequency and the counting period Measurement parameters Frequency period positive pulse width negative pulse width duty cycle After you have set all parameters you can use the multifunctional button to start the counting function The multifunctional button can stop the function 6 MODULATION MODE Press the button to start the modulation mode...

Страница 6: ... The arrow keys can be used to set each parameter After all settings are adjusted you can use the multifunctional button to start each function and to end it 7 SYSTEM CONFIGURATION Press the button to open the setup menu Use the multifunctional buttons to navigate The following settings can be made Save load sound settings configuration of brightness language settings synchronization setting of th...

Страница 7: ...hted presst the buttons to select the point which has to be synchronized Use the multifunctional button to select and to quit the process Settings of the arbitrary wave display The amount of wave forms in the main interface can be adjusted via the rotary button 1 60 very quickly 8 PC SOFTWARE INSTALLATION You can download the latest version of the PC software on our Website Start the installationb...

Страница 8: ...Next enter the installation path and confirm with Next The selection of the modules to be installed must also be confirmed with Next ...

Страница 9: ...ly causes problems in connection with the installation and removal of new hardware and should therefore be disabled Confirm the deactivation with Next Alternatively you can leave the system quick start enabled at your own risk To do so simply uncheck the appropriate box The installation program now performs the corresponding installations After successful installation you can exit the installer ...

Страница 10: ...here you have connected the signal generator to your computer If you are not sure which COMportyouhaveconnectedyoursignalgeneratorto opentheDeviceManager and check the connection in the Connections tab COM LPT Then establish the connection with Connect In the Control Panel which you can reach via the tab at the top of the software you can output the standard waveforms and function signals ...

Страница 11: ...At Extend Function you will find the measuring counting burst sweep and pulse functions In Abitrary you can create various custom waveforms and store up to 15 on the device ...

Страница 12: ...r disposal Small devices which do not have outer dimensions greater than 25 cm can be submitted independently of the purchase of a new product in normal household quantities Possibility of restitution at our company location during our opening hours Possibility of restitution nearby We send you a parcel stamp with which you can send us your old appliance free of charge For this possibility you mus...

Отзывы: