4. PANEL  AND DISPLAY

 

After  the  first  start,  the  welcome  screen  is  displayed,  followed  by  the  main 

screen. The  main screen displays selected voltage and current limits. When 

the output is active, the current actual values are also displayed. On the right 

side of the screen there are icons and prompts that indicate the system sta-

tus. For a detailed description of the display, refer to the following diagram.

 

Voltage settings, arrow 

upwards, M1 data 

group

 

Data input, extract / save 

data from / in data group

 

Current settings, arrow 

downwards, M2 data 

group

 

1,44“ 

LCD

-

Display

 

Rotrary switch, 

key lock

 

Activate / deactivate 

output

 

7

 

8

 

Output voltage (default)

 

Output voltage (current value)

 

13

 

10

 

9

 

11

 

12

 

14

 

15

 

16

 

17

 

18

 

Output current (current value)

 

Output power (current value)

 

Input voltage

 

Limit of output current

 

Lock / enlock keys

 

Normal / abnormal status

 

Constant voltage / current

 

Number of data group

 

Active / inactive output

 

Preset output voltage

 

Main menu

 

Settings

 

Содержание DPS5005

Страница 1: ...an be precisely configured in 0 001A steps The power supply is additionally equipped with a switch off parameter memory and ten programmable data memories The operation of the device has been optimize...

Страница 2: ...uracy of output current 0 50 V 0 5 A 0 250 W 88 g 1 44 39 x 71 42 x 45 x 80 mm 0 5 0 5 3 CONNECTION DETAILS IN IN OUT OUT IN IN OUT OUT Positive input Negative input Positive output Negative output Th...

Страница 3: ...escription of the display refer to the following diagram Voltage settings arrow upwards M1 data group Data input extract save data from in data group Current settings arrow downwards M2 data group 1 4...

Страница 4: ...ough the menu to go to the U SET Voltage or I SET Voltage Limit option Set the Output voltage and or output current limitation according to your requirements You can then use the SET button to return...

Страница 5: ...and press the rotary switch After that rotate the switch to choose the data group by its number which you want to see and edit Press it again to change the status of the option M PRE By activating thi...

Страница 6: ...p at the starting of the device You can configure the device to automatically activate the output when the device is turned on Navigate to do this in the S INI option and set the value to ON to activa...

Страница 7: ...ehold quantities Possibility of restitution at our company location during our opening hours Simac GmbH Pascalstr 8 D 47506 Neukirchen Vluyn Possibility of restitution nearby We send you a parcel stam...

Отзывы: