background image

Degree of Over Shading

Shading will reduce the overall performance of a solar system. During the planning stage of a solar system. Con-

sid- eration should be given to the location of the collectors with the aim of minimising the effects of shading from 

high buildings, trees, etc.

none / little / a lot

Collector Fixing Surface

Is there enough room for the solar panels to sit on the required roof?

(yes/no)

Is there enough between gulleys (top, bottom and both sides) to prevent leafs and debris from gathering 

around the panels?

(yes/no)

Orientation of Roof & Estimated Tilt Angle of Roof for Mounting Solar Collectors

What is the Roof orientation (should be between East SE - West SW)

Collector should be facing the equator

Is an inclinded roof frame need to obtain required pitch?

(yes/no)

To calculate optimal angle of tilt multiple latitude x 0.7 for domestic hot water production

Birr 37.16°,  Cork 36.3°, Dublin 53.43°

Estimating Hot Water Demand & Size of System Required

No. of people using hot water in the house

Any other exceptional water loads in the dwelling

No. of People

Solar Cylinder Size

Size of Flat Panel System

Size of Evacuated Tube

2 Panel System (4m2)

30 Tube System (2.83m2)

1-2 people

200 litres

3 Panel System (6m2)

40 Tube System (3.77m2)

3-5 people

300 litres

Location of Solar Pump Station & Solar Controller

Ensure the pump station is located in an area where it can be easily accessed for servicing & main- tenance

(Confirm)

Ensure that there is adequate space both left and right of pump station to allow easy access to remove pump 

in future.

Ensure that the solar controller is located in an area that is easily accessible for the user

(Confirm)

Ensure that the controller is mounted at the ocrrct height for easy viewing.

(Confirm)

Existing Plumbing System

What type of plumbing system is in the dwelling (vented or un-vented)?

Is solid fuel incorporated into the plumbing system?

Is there adequate access to route pipe work from solar collectors down to cylinder location?

(yes/no)

Is there space in the hot press to locate solar pump station?

(yes/no)

 

Site Survey

5

NAVITAS IN-ROOF

  

 

installation manual   

Содержание Navitas In-roof

Страница 1: ...NAVITAS IN ROOF joule navitas solar in roof flat panel installation manual INSTALL...

Страница 2: ...Installer Loyalty Scheme Coming Soon 2...

Страница 3: ...erview of materials 14 Overview of materials single row 16 Overview of materials double multiple row 17 Overview of tools 18 Mounting single row 34 Mounting double multiple row 43 Specifications 44 Pu...

Страница 4: ...nd manifold boxes should be transported horizontally Heavy goods should not be loaded on top of the kit boxes Care should be taken when opening boxes to prevent scratches or sudden shocks to the glass...

Страница 5: ...Required No of people using hot water in the house Any other exceptional water loads in the dwelling No of People Solar Cylinder Size Size of Flat Panel System Size of Evacuated Tube 2 Panel System 4m...

Страница 6: ...n take the anticipated load Where there is signs of discolouration a closer examination will be requried If black spots are found on the timber this indicates a leak which needs attention If the timbe...

Страница 7: ...isk to fire prevention by installing the solar system confirm Ensure that all wires are not in direct connection with any un insulated pipe work or plant that could cause a risk of burning confirm Leg...

Страница 8: ...Kit Components Solar Pump Solar Controller Solar Expansion Vessel Standard Kit Components Solar Panel Profiles Piping Options DN16 Duo Pipe DN20 Pipe Stainless Tails Copper Solar Fluid 8...

Страница 9: ...Mounting Options Optional Accessories Installation Hose Mounting Set Over Voltage Lightning 3 4 Thermostatic Mixing Valve Cooling Vessel Discharge Vessel 9 NAVITAS IN ROOF installation manual...

Страница 10: ...nel mbar Vissolis 4 Panel mbar Vissolis 6 Panel mbar 2 120 15 8 54 1 18 4 11 3 180 15 12 57 2 87 10 74 4 240 15 17 08 2 36 8 22 5 300 22 21 11 4 05 14 58 6 360 22 25 14 5 74 20 94 8 240 22 33 68 6 92...

Страница 11: ...oof fixing kits for metal and other commercial roofs Two options available utilise appropriate clamps so the fabric of the metal roof is not penetrated see page xx Note the minimum and maximum distanc...

Страница 12: ...Overview of materials Single row R1 double multiple row R2 12...

Страница 13: ...13 NAVITAS IN ROOF installation manual...

Страница 14: ...Overview of materials Single row R1 14...

Страница 15: ...15 NAVITAS IN ROOF installation manual...

Страница 16: ...Overview of materials Double multiple row R2 16...

Страница 17: ...Overview of tools 17 NAVITAS IN ROOF installation manual...

Страница 18: ...Mounting Single row R1 18...

Страница 19: ...19 NAVITAS IN ROOF installation manual...

Страница 20: ...Mounting Single row R1 20...

Страница 21: ...21 NAVITAS IN ROOF installation manual...

Страница 22: ...Mounting Single row R1 22...

Страница 23: ...23 NAVITAS IN ROOF installation manual...

Страница 24: ...Mounting Single row R1 24...

Страница 25: ...25 NAVITAS IN ROOF installation manual...

Страница 26: ...Mounting Single row R1 26...

Страница 27: ...27 NAVITAS IN ROOF installation manual...

Страница 28: ...Mounting Single row R1 28...

Страница 29: ...29 NAVITAS IN ROOF installation manual...

Страница 30: ...Mounting Single row R1 30...

Страница 31: ...31 NAVITAS IN ROOF installation manual...

Страница 32: ...Mounting Single row R1 32...

Страница 33: ...33 NAVITAS IN ROOF installation manual...

Страница 34: ...In roof installation Double multiple row R2 34...

Страница 35: ...35 NAVITAS IN ROOF installation manual...

Страница 36: ...In roof installation Double multiple row R2 36...

Страница 37: ...37 NAVITAS IN ROOF installation manual...

Страница 38: ...In roof installation Double multiple row R2 38...

Страница 39: ...39 NAVITAS IN ROOF installation manual...

Страница 40: ...In roof installation Double multiple row R2 40...

Страница 41: ...41 NAVITAS IN ROOF installation manual...

Страница 42: ...In roof installation Double multiple row R2 42...

Страница 43: ...Stainless Steel Pipe Specification Silicone Cable Specification Insulation Specification Specifications 43 NAVITAS IN ROOF installation manual...

Страница 44: ...8 Insulating EPP box cover Connections of flow and return pipe work to the pump station are made vis the flat face thread connection on all points apart from the connection directly underneath the pum...

Страница 45: ...the pump station consideration should be given to future access for maintenance It is best practice to locate the pump as far downstream the system as possible away from the collectors to help reduce...

Страница 46: ...ould be located at least 100 mm from in sulated pipes which may become hot during operation Control panels use PT1000 sensors containing twin core copper cable with a 0 75mm cross section The sen sors...

Страница 47: ...47 NAVITAS IN ROOF installation manual...

Страница 48: ...48...

Страница 49: ...49 NAVITAS IN ROOF installation manual...

Страница 50: ...Commissioning 50...

Страница 51: ...e until the desired flow rate is achieved Stop the pump Turning The Solar Pump On Manually For Service Press the left or down button the controller until the screen displays the time Press and hold th...

Страница 52: ...ass of the refractometer will display the level of antifreeze in the system If the antifreeze has lost its antifreeze properties the system should be refilled with fresh solar fluid It is recommended...

Страница 53: ...of inspection Expansion vessel setting before filling System pressure Expansion vessel setting before filling Flow rate Antifreeze level pH reading Inspection of barium get ter on tubes Engineer deta...

Страница 54: ...54...

Страница 55: ...55 NAVITAS IN ROOF installation manual...