Jøtul NVI 2000 Скачать руководство пользователя страница 22

22

www.jotul.no

50 mm

50 mm

50 mm

Installation above roof, round hood, stay plate

After making a hole in the roof, inspect the surface 
and make sure that the stay plate is supplied with a 
load-bearing, stable attachment. If not, build a frame 
for attachment.

Install the lower half of the stay plate (the part with-
out the folded up edge). Solder the chimney and then 
secure it to the roof.

Cut a hole in the roofing felt and insert the upper half 
of the stay plate. This is done to prevent condensation 
running out into the roof structure. Secure it to the 
roof.

Then build a frame around the bottom fitting’s con-
necting piece at the same height as the roofing.

Return the cornice and then the roofing.

Thread the roof seal over the chimney module, and 
lower it carefully towards the roofing tiles (so that 
the system chimney’s paintwork does not sustain any 
damage).

Continued: See pages 23-24, depending on roofing.

50 mm

NVI 2000 - ROOF HOOD

The cone

If the cone’s opening does not correspond with the 
roof angle, cut it horizontally before screwing the 
cone/roof seal into place.

Thread the roof seal 
over the chimney 
module, and lower 
it carefully towards 
the roofing tiles 
(so that the system 
chimney’s paintwork 
does not sustain any 
damage).

Содержание NVI 2000

Страница 1: ...23 06 2017 JAN 2019 INSTALLATION GUIDE NVI 2000 Chimneysystem MARKEDETS SIKRESTE ST LPIPE THE SAFEST CHIMNEY ON THE MARKET...

Страница 2: ......

Страница 3: ...ur interior design The choice of NVI ensures a safe and secure product for you and your family FOREWORD Contents Connection duct Combi 31 Getting started 7 Extra cladding pipe Combi 34 Warranty provis...

Страница 4: ...eed for the building application can be found in the pipe s performance declaration in this installation guide and which can also be downloaded from our website www jotul no Fire protection and safety...

Страница 5: ...ney Using NVI s chimney system it is possible to connect multiple fireplaces to the same pipe Certain normative regulations and requirements informative guidelines and calculation methods are set out...

Страница 6: ...GHT ABOVE ROOF If the distance from the roof ridge is 2 3 meter an installation height of 0 4 metres above the roof ridge is recommended SAFETY RESISTANCE TO THE NEAREST FLAMMABLE MATERIALS VERTICAL M...

Страница 7: ...our new fireplace has been used a few times Climbing arrangements If pipe s outlet is higher than 1 2 m at the point where you climb up a work platform or a module must be installed with a sweeping ha...

Страница 8: ...cleaned with most detergents that are suitable for painted surfaces NB Distinguish between detergents and solvents Thinning solvents can damage the powder painted outer casing Grease spots which can a...

Страница 9: ...r chimneys Connected at top Semi insulated Connected at top Uninsulated Connected at rear through inner wall Connected at rear Semi insulated Connected at top Fully insulated Connected at rear Uninsul...

Страница 10: ...ce Rain collar Roof seal Stay plate Diffusion barrier Ceiling ring Rear connection Support leg Wall bracket Angled connection Module Fully insulated Module Semi insulated Bottom fitting Diffusion barr...

Страница 11: ...bottom by the fireplace NB Ensure that the tongue groove system is pressed firmly together also applies to the cladding pipe evt adapter Innertakplate Kulefanger ved behov 300 mm 300 mm evt adapter In...

Страница 12: ...e nut on the foot The length of the cladding pipe must be adapted to the existing installation Start by removing the ring from the bottom of the rear connection Place the cladding pipe to the side of...

Страница 13: ...the ceiling plate The hole must be the same size as the cladding pipe Cut the panel in half and insert the pieces up into the floor structure around the chimney ROUND COVER PLATE in degree interval 2...

Страница 14: ...insulation sup plied with ceiling ring is then used next to the ceiling Where the floor structure s insulation is up to 400 mm thick not loose wool rock wool insulation made of a mesh reinforced mat...

Страница 15: ...required Some distance is required for clearance and space for a length extension NVI 2000 THROUGH CONNECTIONS Walls and roofs in houses When making a hole in a house it is extremely important for the...

Страница 16: ...e safe ty distance of 50 mm is satisfied throughout the installation NB Do not place the adapter in the wall through connection DIAMETER FLUE PIPE A MM 125 258 150 258 190 258 250 318 50 mm B min 50 m...

Страница 17: ...ece if one is used NB When installing a wall bracket with an extension piece start by assembling the wall bracket and extension piece with screws and nuts in the fixed holes Note that both parts must...

Страница 18: ...screws Solder the pipe Secure the bottom fitting to the ceiling then tighten the screws for the stay ring in the bottom fitting Note the distance of 50 mm from cladding to flamma ble material Bottom f...

Страница 19: ...the entire row of tiles Pay attention to runoff Ensure that the rubber membrane is shaped so that there can be no stand ing water Take particular care at the transition between roofing tiles and the l...

Страница 20: ...centre over the bottom fitting and screw into place Make sure that the roofing is clean Roll out the alu minium membrane and remove the protective tape then shape the membrane so that it seals tightl...

Страница 21: ...them at the joints with screws on all sides Pre drill using a 3 mm drill bit Minimum 10 cm overlap at the joints A A 450 mm mm 410 mm Installation of telescopic section and rain protection The telesco...

Страница 22: ...he roof structure Secure it to the roof Then build a frame around the bottom fitting s con necting piece at the same height as the roofing Return the cornice and then the roofing Thread the roof seal...

Страница 23: ...he roofing In some cases it may be necessary to cut roofing tiles Then place the roof seal in position centre over the roof plate and screw into place Make sure that the roofing is clean Roll out the...

Страница 24: ...roof seal or extension plate NVI 2000 ROOF HOOD Installation advice Alumembrane Installation advice alumembrane It is important to seal the transition between the roofing and pipe wall boxes skylight...

Страница 25: ...r joint on the rain collar This must be done before the attach ment bolt has been completely tightened to ensure that the rain collar is not pulled crooked leading to leaks Finally tighten the attachm...

Страница 26: ...flue pipes can be cut with an an gle grinder jigsaw or hack saw Cut the cladding pipe with care as this part is visible The insulation can be cut with an insulation saw or knife Cut the insulation on...

Страница 27: ...correct position Continue to install the correct chimney sections bearing in mind the location of any cleaning hatches so that they are easily accessible NB In the case of external installation a spe...

Страница 28: ...28 www jotul no NVI 2000 COMBI...

Страница 29: ...ised definitions NVI 200COMBI SS EN 1856 1 2009 T450 N1 D W V2 L50100 G50 The NVI 2000 Combi is not intended for the use of several fireplaces in the same pipe Otherwise the same advice and provisions...

Страница 30: ...ct 60 mm insulation Rain top Rain protector piece Rain collar Roof seal Stay plate Ceiling ring Connecting piece Connecting duct Module Fully and semi insulated Standard and Combi Bottom fitting Diffu...

Страница 31: ...odule so that the insulation is secured during installation Installation of NVI2000 COMBI Connecting duct Read through the fireplace producer s guidelines regarding supply air Depending on the firepla...

Страница 32: ...e safety distance of 50 mm to flammable mate rials must always be observed Use the insulation that is supplied with the ceiling plate as this acts as protection against draughts When making holes the...

Страница 33: ...uppermost cladding pipe Roof hood square When adapting the chimney length it is important to ensure that the supply air is able to pass freely through the top of the chimney Leave a distance of at lea...

Страница 34: ...ngth so that the rubber ring is cut off Install the enclosed distance strips inside the pipe three strips with equal spacing at the bottom and the same at the upper edge Then install the extra claddin...

Страница 35: ...ccordance with the produces recommendations and the fireplace must be used with fuel that is approved for the chimney In addition the chimney must not be exposed to flue gas temperatures in excess of...

Страница 36: ...ble materials been checked COMMENTS Has the height above the roof been checked COMMENTS Has the potential to sweep the chimney been checked COMMENTS Is there safe access for a chimney sweep on the roo...

Страница 37: ...of such a confirmation is also essential for J tul s warranty for the product Ensure that this page is filled out and that a copy is sent to the local authority s chimney sweep service Look after the...

Страница 38: ...B C 235 565 330 410 740 580 620 950 880 800 1130 1130 1050 1380 1480 1220 1550 1730 1440 1770 2030 1610 1940 2280 1860 2190 2630 2670 3000 3780 3490 3820 4930 4300 4630 6080 5110 5440 7230 Angle 52 f...

Страница 39: ...250 1770 2320 2500 2015 2565 2850 2830 3380 4000 3640 4190 5150 4455 5005 6300 5270 5820 7450 Angle 52 for roof pitch 38 A B C 435 890 550 630 1040 800 870 1230 1100 1065 1380 1350 1340 1600 1700 1540...

Страница 40: ...fasthet 0 6kN Icke vertikal installation Maximalt 1 5 m mellan f stpunkter 15 90 H llfasthet f r vindlast Maximalt 1 8 m frist ende ver tak utan stag Resistens mot vatten och ngdiffusion Uppfyller Res...

Страница 41: ...r Dragh llfasthet 0 6kN Icke vertikal installation Maximalt 1 5 m mellan f stpunkter 15 45 H llfasthet f r vindlast Maximalt 1 8 m frist ende ver tak utan stag Resistens mot vatten och ngdiffusion Upp...

Страница 42: ...A H llfasthet f r vindlast Maximalt 1 8 m frist ende ver tak utan stag Resistens mot vatten och ngdiffusion Uppfyller Resistens mot kondensat Uppfyller Resistens mot korrosion Uppfyller V2 Resistens f...

Страница 43: ......

Страница 44: ...TAD E mail st lpipe jotul no www jotul no Follow us on Facebook www facebook com jotulint J tul continuously strives to improve its products and reserves the right to modify specifications colours and...