4
139810_R4 GF 400 BF CE
2
7/18
1. Technical Information
THIS APPLIANCE IS FACTORY-EQUIPPED
TO USE ONLY NG (G20/25).
THIS APPLIANCE IS NOT FUEL
CONVERTIBLE.
SEE THE ATTACHED DATA PLATE
AND SHIPPING LABELS FOR FUEL
IDENTIFICATION AND SPECIFICATIONS.
DO NOT SUBSTITUTE ANY TYPE OF GAS
OTHER THAN THAT SPECIFIED FOR THE
MODEL DESIGNATED ON THE DATA PLATE.
Technical Data
-
Jøtul GF
400
BF CE
2
PIN
0558
CN
1873
Countries of Destination
AT, BG, CH, CZ
DK, EE, ES, FI
GB, GR, HR, IE
IT, LT, LV, NO, PT
RO, SE, SI, TR
DE,
LU,
PL,
RO
BE, FR
NL
Gas Type
NATURAL GAS
G20
G20
D
G25
G20
D
G25.3
G25
Gas Category
I
2H
I
2E
I
2E+
I
2EK
I
2L
Supply Pressure
(mbar)
20
20
D
25
20
D
25
25
Nominal Heat Input
(Net, kW)
7.0
7.0
D
6.4
7.0
D
7.6
6.4
Burner Pressure at Full Rate - Hot
(mbar) ±1 (0mbar)
5.9
5.9
D
7.4
5.9
D
7.4
7.4
Maximum Gas Consumption
(m
3
/h)
15°C, 1`013 .25 mbar
0.740
0.740
D
0.787
0.740
D
0.793
0.787
Main Burner Injector Marking
(x1)
33
Efficiency
Horizontal termination (%, nett) Verti-
cal termination (%, nett)
81.1
83.6
81.1
D
79.9
83.6
D
82.6
81.1
D
80.4
83.6
D
82.6
79.9
82.6
Maximum Heat Output
Horizontal termination (kW)
Vertical termination (kW)
5.7
5.9
5.7
D
5.1
5.9
D
5.3
5.7
D
5.3
5.9
D
5.5
5.1
5.3
Efficiency Class
2
NOx Class
5
Flue Type
C
11
or C
31
Concentric Flue Diameter
(inner/outer)
100/150mm