Jøtul F 232 Скачать руководство пользователя страница 4

4

Jøtul F 234

Product:

Room heater fired by solid fuel

Standard
Minimum distance to adjacent combustible materials
Minimum distance to adjacent combustible materials
Emission of CO in combustion products (13% O  )
Flue gas temperature
Emission of dust in combustion products (13% O  )
Nominal heat output
Efficiency
Fuel type
Operation type
The appliance can be used in a shared flue.

: EN 13240
: Side 350mm
: Rear 125mm
: 0,06%
: 271 °C
: 6 kW
: 80%
: Wood
: Intermittent

Country

Classification

Standard

Approved by

Norway

EUR

Klasse II

Intermittent

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten.

Follow user's instructions. Use only recommended fuels.

2

EN 13240

17

DANISH TECHNOLOGICAL
INSTITUTE

Country

Classification

Approved by

Standard

Respectez les consignes d'utlisation. Utilisez uniquement

les combustibles recommandés.

Jøtul AS, POB 1411, N-1602  Fredrikstad, Norway

Lot no: 000000 Year: 2017

Pin:

000

Manufacturer:

Austria

15 A

2

NS: 3058

Germany

1.BlmSchV
Stufe 2

EN 13240/Din+

DANISH
TECHNOLOGICAL
INSTITUTE

10053152-P00

Serial no.

23000000

Table of contents

1.0    Relationship to the authorities ..................... 4

2.0    Technical data ................................................. 4

3.0   Safety ...............................................................5

4.0   Installation ..................................................... 8

5.0    Daily use ........................................................ 13

6.0   Maintenance .................................................14

7.0   Service ............................................................ 15

8.0    Operational problemes -

 

    troubleshooting ............................................18

9.0   Optional Equipment .....................................18

10.0   Recycling ........................................................19

11.0   Guaranee terms ............................................19

 

Register your fireplace at jotul.com for a 

25-year warranty.

On all our products there is a label 

indicating the serial number and 

year.  Write this number in the 

place indicated in the installation 

instructions.
Always quote this serial number 

when contacting your retailer or 

Jøtul.

1.0 Relationship to the     

      authorities

Installation of a fireplace must be according to local codes 

and regulations in each country.
All local regulations, including those which refer to 

national and European standards, must be observed 

when installing the product.

The  installation  can  only  be  put  into  use  after  it  has  been 

checked by a qualified inspector. Contact your local building 

authorities before installing a new fireplace.

2.0 Technical data

Material:  

 

 

Cast iron / 

steel plate

Finish:    

 

 

Black paint

Fuel:    

 

 

Wood

Log length, max.:   

 

33 cm

Flue outlet: 

 

 

Top, rear

Flue pipe dimension: 

 

Ø 150 mm

Approx. weight:

- Jøtul F 232: 

 

 

129 kg

- Jøtul F 233: 

 

 

130 kg

- Jøtul F 234: 

 

 

153 kg

- Jøtul F 235: 

 

 

150 kg

Optional extras:   

 

Glass floor plate 

 

 

 

 

(small or large)

     

    

Modules for chimney  

    coupling

 

 

 

 

Extra kit for rear outlet

 

 

 

 

Extra kit for top outlet

Dimensions, distances: 

 

See fig. 1 & fig. 2

Technical data in acc. with EN 13240 / NS 3058

Nominal heat output: 

 

6 kW

Flue gas volume:  

 

5,3 g/s

Chimney draught, EN 13240: 

12 Pa

Recommended negative pressure

in smoke outlet:   

 

16-20 Pa

Efficiency: 

 

 

80% 

CO emissions (13 % O

2

):   

0.06%

CO emissions (13 % O

2

):   

803 mg / Nm

3

NOx at 13% O

2

:   

 

81 mg / Nm

OGC at 13 % O

2

:     

 

43 mg/Nm

3

Air consumption:   

 

16-25 m

3/h

Chimney temperature EN 13240:  271 

ºC

Dust (13 % O2

):   

 

<21 mg/Nm

3

Type of fuel:  

 

 

Wood

Recommended log length:  

27-30 cm

Max. log length:    

 

33 cm

Fuel consumption: 

 

1,9 kg/h

Max. kindling amount: 

 

2,25 kg

Nominal kindling amount:   

1,5 kg

Operation: 

 

 

Intermitterende

Intermittent combustion in this context means normal use of 

the fireplace, i.e. fuel is added as soon as the fuel has burnt 

down to a suitable amount of embers.

Содержание F 232

Страница 1: ...tul F 230 UK Installation and Operating Instructions J tul F 230 Manual Version P00 The manuals which are enclosed with the product must be kept throughout the product s entire service life Register y...

Страница 2: ...assemblage l installation ou l entretien de l appareil Cualquier precauci n espec fica que deba tenerse en cuenta durante el montaje instalaci n o mantenimiento del equipo de calefacci n Precauzioni...

Страница 3: ...3...

Страница 4: ...in the place indicated in the installation instructions Always quote this serial number when contacting your retailer or J tul 1 0 Relationship to the authorities Installation of a fireplace must be a...

Страница 5: ...se your fireplace The following instructions must therefore be followed The minimum safety distances when installing and using the fireplace are given in fig 1 The specified distance to flammable mate...

Страница 6: ...LE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230125 idw 90230125 M lskitse model 235 14 05 2018 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 1012 236 5 399 204 1...

Страница 7: ...NR EMNE C Working Folder Designs J tul F230 90230125 idw 90230125 M lskitse model 235 14 05 2018 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 1012 236 5 399 204 195 972 5 831 470 J tul F 235 J tul F...

Страница 8: ...ews F in the sidesandatthefrontinordertofreethestovefromthepallet 2 The AEA blocking B is mounted with the 2 screws C and the 2 nuts D at the stove s secondary air valve E 4 0 Installation Before inst...

Страница 9: ...til br ndbar v g 21 08 2017 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 50 254 NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230154 idw 90...

Страница 10: ...fore a hole is made in the chimney the product should be test mounted in order to correctly mark the position of the fireplace and the hole in the chimney See fig 1 for minimum dimensions The flue pip...

Страница 11: ...sts of a double pipe The outer pipe is used by the stove to draw in fresh air for the combustion The inner pipe is used by the stove to exhaust the burnt gases This is called a balanced vent 1 The ada...

Страница 12: ...ith top outlet 1 Position the product correctly see fig 1 2 Position the d cor ring accessory C in the top outlet 3 Pass the flue pipe A through the d cor ring C and the top plate and mount it in the...

Страница 13: ...older Designs J tul F230 90230120 idw 90230120 Gulvplade DK NO SE 05 07 2017 jm tul F 230 V GT AREAL N A N A DIM Scan A S A DATO SIGN DK 5492 Vissenbjerg TG NR EMNE orking Folder Designs J tul F230 90...

Страница 14: ...tion Avoid smouldering fires as this produces the most pollution The fire is best when it is burning well and the smoke from the chimney is almost invisible Wood consumption J tul F230 has a nominal h...

Страница 15: ...oduct is equipped with an air wash for the glass Air is sucked in through the air vent on the top of the product and down along the inside of the glass However some soot will always stick to the glass...

Страница 16: ...uld be cleaned and brushed free of any loose particles before new paint is applied Important Never place anything on the top plate of the stove This could cause permanent damage to the paint or enamel...

Страница 17: ...0 V GT AREAL 19 49 kg 1074904 mm 2 DIM Scan A S C NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230151 idw 90230151 Udskiftning af frontglas 2...

Страница 18: ...18 08 2017 jm J tul F 230 V GT AREAL N A N A DIM Scan A S NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230144 idw 902301 Udskiftning sideglas...

Страница 19: ...ses from escaping branches trees etc Upon suspicion of excessive poor draught in the chimney seek professional help for measurement and adjustment The fire extinguishes after a while Make sure that th...

Страница 20: ...3 mm 4 Allen screws M5x10 1 Allen screw M5x50 FZB art no 51053190 10 0 Recycling 10 1 Recycling packaging Your fireplace is delivered with the following packaging A wooden pallet that can be cut up an...

Страница 21: ...nditions air supply or other circumstances beyond J tul s control 2 4 Cases involving alterations modifications to the fireplace without J tul s consent or the use of non original parts 2 5 Damage cau...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...J tul AS has a quality system that conforms to NS EN ISO 9001 for product development manufacturing and distribution of stoves and fireplaces This policy gives our customers quality and safety piece...

Отзывы: