background image

17

8.0  Operational problems - 
troubleshooting

Poor draught

Check the length of the chimney and that it complies with 
national laws and regulations. (See also 

«2.0 Technical 

data» 

and

 «4.0 Installation» (Chimney and 

fl

 ue pipe)

 in the 

installation manual for information.)
Make sure that the minimum cross section on the chimney is 
according to 

«2.0 Technical data» 

in the installation manual. 

Make sure that there is not anything preventing the smoke 
gasses from escaping: branches, trees, etc.
Upon suspicion of excessive/poor draught in the chimney, 
seek professional help for measurement and adjustment.

The 

fi

 re extinguishes after a while

•  Make sure that the 

fi

 rewood is su

  ciently dry.

•  Find out whether there is negative pressure in the house, 

close mechanical fans and open a window close to the 

fi

 replace.

•  Check that the air vent is open.
•  Check that the 

fl

 ue outlet is not clogged by soot.

Unusual amount of soot accumulates on 
the glass

Some soot will always stick to the glass, but the quantity 
depends on:
•  Moisture in the fuel.
•  The local draught conditions.
•  Air vent opening. 
Most of the soot will normally burn o

  when the air vent is 

opened all the way and a 

fi

 re is burning briskly in the 

fi

 replace. 

(See «6.1 Cleaning the glass».)

9.0 Optional equipment

9.1 Additional heat shield, rear

Art. no. 50012956

9.2 Smoke outlet for UK, Ø 125 mm

Art. no. 51012033

10.0 Recycling

10.1 Recycling packaging

Your 

fi

 replace is delivered with the following packaging:

•  A wooden pallet that can be cut up and burned in the 

fi

 replace.

•  Cardboard packaging that should be taken to a local 

recycling facility.

•  Plastic bags that should be taken to a local recycling facility.

10.2 Recycling the 

fi

 replace

The 

fi

 replace is made of:

•  Metal that should be taken to a local recycling facility.
•  Glass that should be disposed of as hazardous waste. 

The glass in the 

fi

 replace must not be placed in a regular 

source segregation container.

•  Vermiculite burn plates that can be disposed of in regular 

waste containers.

ENGLISH

11.0 Guarantee terms

1.  Our guarantee covers:

Jøtul AS guarantees that the external cast-iron parts are 
free from defects in materials or manufacturing at the time of 
purchase. You may extend the guarantee on the external cast-
iron parts to 25 years from the date of delivery by registering 
the product on jotul.com, and print out the extended guarantee 
card within three months of purchase. We recommend that 
the guarantee card be kept together with the receipt. Jøtul AS 
also guarantees that steel plate parts are free from defects in 
materials or manufacturing at the time of purchase for a period 
of 5 years from the date of delivery.

The guarantee applies on the condition that the stove has been 
installed by a quali

fi

 ed installer in accordance with applicable 

laws and regulations and Jøtul’s installation and operating 
instructions. Repaired products and replacement items are 
guaranteed within the original guarantee period.

2.  The guarantee does not cover:

2.1.  Damage to consumables such as burn plates, 

fi

 re grates, 

fl

 ue ba

  es, gaskets and similar as these deteriorate over 

time due to normal wear and tear.

2.2. Damage caused as a result of improper maintenance, 

overheating, use of unsuitable fuel (e.g of unsuitable fuel 
are, but not limited to driftwood, impregnated wood, plank 
o

 cuts, chipboard ) or too moist / wet wood.

2.3.  Installation of optional extras for the purpose of rectifying 

local draught conditions, air supply or other circumstances 
beyond Jøtul’s control.

2.4.  Cases involving alterations / modi

fi

 cations to the 

fi

 replace 

without Jøtul’s consent or the use of non-original parts.

2.5.  Damage caused during storage at a distributor, transport 

from a distributor or during installation.

2.6. Products sold by unauthorized sellers in areas where 

Jøtul operates a selective distribution system.

2.7. Associated cost (e.g.but not limited to, transport, 

manpower, travel) or indirect damages.

Pellets stoves, glass, stone, concrete, enamel and paint 

fi

 nish (e.g. but not limited to chipping, cracking, bubbling or 

discolouration and crazing) are applicable to the national 
legislation governing the sale of consumer goods. This 
guarantee is valid for purchases made within the territory of 
the European Economic Area. All guarantee inquiries must 
be addressed to your local authorized Jøtul dealer within a 
reasonable amount of time, which shall not be later than 14 
days from the date on which the fault or defect 

fi

 rst  became 

apparent. See list of importers and dealers on our web site 
www.jotul.com.

If Jøtul is unable to meet the obligations outlined in the above 
guarantee terms, Jøtul will o

 er a replacement product with a 

similar heating capacity free of charge.

Jøtul reserve the right to decline of any replacement of parts 
or service in the event that the guarantee is not registrated 
online. This guarantee does not a

 ect any rights under 

applicable national legislation governing the sale of consumer 
goods. The national complaint right applies from the purchase 
date and only in exchange for a receipt / serial number.

Содержание F 100 ECO.2 LL

Страница 1: ...ie en montagehandleiding 61 DE Montage und Gebrauchsanleitung 75 J tul F 100 ECO 2 Manual Version P03 Manualen m oppbevares under hele produktets levetid Manualen skal opbevares under hele produktets...

Страница 2: ...gy efficiency index 1 Efficiency at nominal heat output 8 Any specific precautions that shall be taken when the local space heater is assembled installed or maintained Fire safety precautions such as...

Страница 3: ...nerse en cuenta durante el montaje instalaci n o mantenimiento del equipo de calefacci n x Precauzioni specifiche da prendere quando il riscaldatore viene assemblato installato o mantenuto in uno spaz...

Страница 4: ...ent combustion in this context means normal use of the fireplace i e fuel is added as soon as the fuel has burnt down to a suitable amount of embers Register your fireplace at jotul com for a 25 year...

Страница 5: ...2 SL SE J tul F 100 ECO 2 LL and J tul F 100 ECO 2 LL SE must be fitted with a permanent stop to prevent closure of the secondary air control beyond 40 open 3 1 Fire Prevention Measures There is a cer...

Страница 6: ...nal hearth which must have an extension of minimum 350 mm in front of the stove For further information please see Approved Document J2010 Section 2 22 J tul F 100 ECO 2 LL Long Legs J tul F 100 ECO 2...

Страница 7: ...ineral wool cilicate plates etc materials that do not burn Note A short distance to non combustible wall may lead to desiccation and discoloration of paint and cause cracking The stove must be set up...

Страница 8: ...han 470 mm2 A 1 Push the air vent A to the right B 2 Use the pin screw B from the bag of screws and screw it onto the burnchamber 4 2 Installation Assembly of flue pipe with top outlet The product is...

Страница 9: ...be rear mounted do the following NB In order to make the change you must first remove the ba e plate see fig 23 24 Remember to put it in place later Fig 7 A 1 Unscrew the screw A and remove the rear...

Страница 10: ...screws B Fig 11 A 4 Cut out the part A in the heat shield for the flue pipe Fig 12 5 Install the rear heat shield onto the stove Fig 13 1 2 6 Remove the protective paper from the gasket and fasten it...

Страница 11: ...fireplace Use 2 0 Technical Data to calculate the correct chimney cross section The chimney must be connected in accordance with the installation instructions of the chimney supplier Before a hole is...

Страница 12: ...must not be operated with air controls appliance dampers or door left open except as directed in the instructions Operation with the door open can cause excess smoke The appliance must not be operated...

Страница 13: ...firebed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a su cient quantity of glowing embers and ash that the new fuel charge will ignite in a reaso...

Страница 14: ...mover In order to prevent a water and tar layer from forming in the fireplace you should regularly allow the fire to burn hot in order to remove the layer An annual internal cleaning is necessary to g...

Страница 15: ...haust deflector Baffle plate Left burn plate Right burn plate Rear bottom plate Fire grate Ash pan 7 2 Replacing the ba e plate burn plates and fire grate Fig 22 1 Remove the ash lip Fig 23 1 2 2 Lift...

Страница 16: ...ft the fire grate and tilt it out Fig 27 A Remove the rear bottom plate A When refitting First place the rear bottom plate Place the ash pan and the fire grate Place the left side burn plate Put the b...

Страница 17: ...ard be kept together with the receipt J tul AS also guarantees that steel plate parts are free from defects in materials or manufacturing at the time of purchase for a period of 5 years from the date...

Отзывы: