Check for defects on the EPIRB and its bracket
o
Make sure that the bracket is not covered by paint or any
other chemicals.
o
Check that the lanyard is firmly attached to the EPIRB, and
not tied to the vessel or any other objects.
o
Check the expiry dates of the battery and the HRU. The
hydraulic release unit expires at the end of the indicated
month.
Expiry month location
Expiry year location
6.2
Every 3 months
•
Perform an extended self-test. See chapter 5.5.2
6.3
Every 12 months
The Tron 40AIS is under the regulation of the IMO MSC.1/Circ 1040 rev 1,
which requires annual testing performed by authorized radio-surveyor or
authorized personnel trained and certified by Jotron.
6.4
Every 2
nd
year
•
Replace the HRU including the plastic bolt. See chapter 6.7 for
description
•
Mark a new expiry date on the HRU label