background image

 
 

Doc. No.: 87634 Rev. G 

jotron.com

 

Page 33 of 48 

 

9.2

 

Testing  

It is important to perform regular testing of equipment to ensure proper 
operation. This also ensures the EPIRB is in good working order and 
therefore ready for use in a potential emergency.  

9.2.1

 

Self-test 

The purpose of a self-test is to verify that the EPIRB functions as it should. 
During this test, a short test signal on 121,5MHz and 406,037MHz are sent 
to test the output of the transmitter and operation of the EPIRB. While 
transmitting the test signal, the battery voltage and status, output power 
and phase lock are tested. When testing the 406MHz transmitter a test 
message is transmitted, this test message is coded with a special 

synchronization code that will not be recognized as an actual alert by the 
Cospas-Sarsat satellites. 
There are two types of tests: 

1.

 

Self-test 

2.

 

Extended self-test including GPS test 

 

 

Testing should be completed within the first 5 mins of 
an hour as the satellite EPIRB emits a 121,5MHz signal 

during testing. 

To perform a self-test, do the following: 

1.

 

Move the switch from the ready position to the test position and 
hold for 15 seconds. 

 

Содержание FB-40

Страница 1: ...Tron 40VDR Capsule FB 40 and FBH 40 Float free brackets User manual...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...IBRD International 406MHz Beacon Registration Database IEC International Electrotechnical Commission IMO International Maritime Organization ITU International Telecommunication Union LED Light Emitti...

Страница 4: ...ion 16 5 3 3 False alerts transmitted by EPIRB 17 6 Functional description 18 6 1 Tron 40VDR components 18 6 2 Main module 19 6 3 Antenna 19 6 4 Battery module 19 6 5 FB 40 float free bracket 19 7 Ins...

Страница 5: ...formation 41 12 1 Handling and storage 41 12 1 1 Transportation 41 13 Technical specifications 42 13 1 Product specification 42 13 2 COSPAS SARSAT transmitter 42 13 3 Navigation device 42 13 4 Homing...

Страница 6: ...n 40VDR w storage module 13 Figure 2 FB 40 float free bracket 13 Figure 3 Illustration signal detection 15 Figure 4 Illustration Tron 40VDR components 18 Figure 5 Illustration automatic operation of a...

Страница 7: ...les Table 1 EPIRB control functions 14 Table 2 Satellites LEOSAR GEOSAR 16 Table 3 Tron 40VDR components 19 Table 4 Tron 40VDR maintenance requirements 30 Table 5 Tron 40VDR self test error codes flas...

Страница 8: ...ntained within this manual has been verified and is to Jotron s knowledge correct Jotron reserves the right to make changes to any product s module s described herein to improve design function or rel...

Страница 9: ...hods of testing and required test results IEC 60945 Ed 4 0 including IEC 608945 Corrigendum 1 Corrigendum 1 Maritime navigation and radiocommunication equipment and systems General requirements Method...

Страница 10: ...lite EPIRBs within 5 years or by the date of battery expiry whichever is first As it applies to maintenance servicing and tested for vessel that requires GMDSS compliant equipment SOLAS Chapter IV reg...

Страница 11: ...jotron com Page 11 of 48 IMO MSC 1 Circ 1222 Regarding an additional yearly testing requirement for the Tron 40VDR float free capsule IMO COMSAR Circ 32 latest revision Correct installation and stora...

Страница 12: ...r There are two float free mounting brackets available for use with the Tron 40VDR either the FB 40 or the FBH 40 which including heating Both brackets are specially designed with an internal safety s...

Страница 13: ...Doc No 87634 Rev G jotron com Page 13 of 48 5 1 Product images Figure 1 Tron 40VDR w storage module Figure 2 FB 40 float free bracket...

Страница 14: ...oiska Avariynich Sudov which means Space System for the Search of Vessels in Distress The Cospas Sarsat system was introduced in 1982 as a worldwide search and rescue system with the help of satellite...

Страница 15: ...to the dealer upon purchase or when the Tron 40VDR was obtained is correct It is also important that the EPIRB is registered in the database for each country This database is normally located in the...

Страница 16: ...on Control Centre MCC will contact the vessel or the contact person registered in the shipping register and or EPIRB register ship owner family member etc before alerting the Rescue Coordination Centr...

Страница 17: ...rmation and telephone number must be accurate as it is what will be used to validate an alert The United States Coast Guard USCG will only launch an immediate rescue if the beacon registration and app...

Страница 18: ...To report a false alarm outside of the US contact the national authority where the beacon is registered 6 Functional description 6 1 Tron 40VDR components An overview of the components Figure 4 Illus...

Страница 19: ...e battery module supplies the EPIRB with power to keep the EPIRB transmitters active for 168 hours when activated and for test sequences The battery module is integrated within the product Two water d...

Страница 20: ...ect water spray chemicals oil exhaust and vibrations 7 1 1 Mounting the FB 40 float free bracket Refer to the Tron 40VDR FF Capsule Installation manual for steps regarding how to complete the mounting...

Страница 21: ...is not mounted correctly on a flat surface If there is a gap between the docking module and the storage module then communication between the two will either be intermittent or non existent 4 Place th...

Страница 22: ...Doc No 87634 Rev G jotron com Page 22 of 48 5 While fitting the black plug into place gently press the cover 6 Using the cotter pin secure the cover...

Страница 23: ...to be operated either manually or automatically The EPIRB will automatically start to transmit when immersed into water The Tron 40VDR has an internal safety switch which prevents inadvertent activat...

Страница 24: ...on Keep the EPIRB in an open area and away from metal objects to ensure best performance this includes ship construction Do not tie the lanyard to a ship during an emergency this prevents the EPIRB fr...

Страница 25: ...Doc No 87634 Rev G jotron com Page 25 of 48 3 Remove the EPIRB from the bracket 4 Pull the safety ring...

Страница 26: ...26 of 48 5 Push and move the main switch to the ON position The LED indicator located at the top of the antenna will start to flash This indicates that the EPIRB is transmitting 6 Tie the EPIRB lanyar...

Страница 27: ...et the EPIRB will automatically be released 2 The EPIRB will then float to the surface and start transmitting 3 Transmission is indicated by the flashing LED and will continue until the EPIRB is lifte...

Страница 28: ...40 float free bracket 8 3 Wrist strap In an emergency the EPIRB can be carried using a Jotron wrist strap Use the strap when it is necessary to have both arms free To use the wrist strap do the follo...

Страница 29: ...be inspected The EPIRB should be self tested in the bracket Perform inspection and testing following with steps outlined in this manual Every 4th month perform an extended self test GPS test instead o...

Страница 30: ...e Table 4 Tron 40VDR maintenance requirements 9 1 Inspection The lifetime of any equipment depends on how well you take care of it Inspect both the Tron 40VDR and the FB 40 float free bracket for defe...

Страница 31: ...e Tron 40VDR must meet these additional requirements To complete the additional requirements do the following 1 Remove and clean the old grease from both the docking module and the storage module 2 Ap...

Страница 32: ...nction of the grease is to prevent ingress of water between the docking module and the storage module this ensures good data transmission If the layer of grease is too thick it may have a negative eff...

Страница 33: ...on of the EPIRB While transmitting the test signal the battery voltage and status output power and phase lock are tested When testing the 406MHz transmitter a test message is transmitted this test mes...

Страница 34: ...r codes flashes If the self test detects an error in the EPIRB module one or more of the following will occur Number of Flashes Error codes 2 Low power on 406MHz transmitter 3 Low battery voltage 4 Lo...

Страница 35: ...t on 406 037 MHz An EPIRB tester can be used to verify the GPS position during a self test Limit this test to a maximum of once a month as this testing reduces the lifetime of the EPIRB battery The Tr...

Страница 36: ...flashes or beeps 9 2 2 1 Error codes beeps If the GPS test detects an error one of the following will occur Number of Beeps Error codes 5 Did not acquire GPS positioning 10 Number of GPS test above l...

Страница 37: ...Doc No 87634 Rev G jotron com Page 37 of 48 2 Remove the cover 3 Remove the EPIRB from the bracket...

Страница 38: ...8 of 48 4 Press down and hold in place the spring loaded catapult then remove the HRU by sliding it out of the locking slot 5 While holding the catapult down slide the new HRU into the locking slot 6...

Страница 39: ...f 48 7 Verify no gaping between the bracket and cover 8 Close and secure the top cover using the cotter pin Ensure that the top cover is locked into place at the bottom and that the top end is fixed a...

Страница 40: ...No 87634 Rev G jotron com Page 40 of 48 11 Test and maintenance records Below is an overview of all test and control details Date B N T Signature Inspector name B New battery N New EPIRB installed T T...

Страница 41: ...batteries must ensure the batteries are isolated from combustibles A short circuit for a few seconds will not seriously affect the battery A prolonged short circuit will cause the battery to lose ene...

Страница 42: ...F to 131 F Temperature storage 30 C to 65 C 22 F to 149 F Operating life Minimum 168 hours at 20 C Lanyard length 5 meters Lanyard strength 25kg 13 2 COSPAS SARSAT transmitter Frequency 406 037MHz 2p...

Страница 43: ...lass reinforced ASA acrylonitrile styrene acrylate Dimensions H W D 553mm x 215mm x 236mm Weight 2900grams Release mechanism Jotron HRU Temperature operating 30 C to 65 C 22 F to 149 F Temperature sto...

Страница 44: ...l certificate 16 Recycling and disposal This product should not be disposed as normal waste and must be handled in accordance with the applicable federal state and local waste disposal regulations in...

Страница 45: ...eassembling of any Jotron product that occurs externally from a Jotron authorized facility and or is handled by someone other than an authorized training and certified person 18 1 Service agents Refer...

Страница 46: ...text Ch 2 2 4 2 SEH C 29 10 2014 Added new spare part number WB D 22 12 2014 Front back covers updated added 1 2 WB E Not released WB F 22 10 2018 Updated mounting description of bracket cover operat...

Страница 47: ...Doc No 87634 Rev G jotron com Page 47 of 48 20 Emergency instructions This is an overview of how to operate a Tron 40VDR during an emergency Figure 6 Emergency instructions overview...

Страница 48: ...64 Tel 65 65 42 63 50 USA Jotron USA Inc 6300 Rothway Street Suite C Houston TX 77040 USA Tel 1 713 268 1061 UK Jotron UK Ltd Crosland Park Cramlington NE23 1LA UK Tel 44 1670 712000 CHINA Norway Jotr...

Отзывы:

Похожие инструкции для FB-40