Doc. No.: 87634 Rev. G
jotron.com
Page 30 of 48
Every 4-5
years
The battery must be replaced and changed at a Jotron SBM
authorized location (to be GMDSS compliant). Test in accordance
with MSC. 1039 SBM. The SMB is decided by the flag state
administration.
Every 10
years
Jotron recommends that the EPIRB and FB-40 float free bracket
are replaced at this time.
Table 4 Tron 40VDR maintenance requirements
9.1
Inspection
The lifetime of any equipment depends on how well you take care of it.
Inspect both the Tron 40VDR and the FB-40 float free bracket for defects.
To inspect, do the following:
1.
Ensure the bracket cover is not blocked (this hinders the release
functionality of the EPIRB).
2.
Ensure the EPIRB and bracket are clean (no paint, oil and other
chemicals).
3.
Verify the lanyard is attached (on the EPIRB and not the vessel)
4.
Verify the expiry date of EPIRB battery.
5.
Verify the expiry date of HRU (month/year)
Содержание FB-40
Страница 1: ...Tron 40VDR Capsule FB 40 and FBH 40 Float free brackets User manual...
Страница 2: ...This page is intentionally left blank...
Страница 25: ...Doc No 87634 Rev G jotron com Page 25 of 48 3 Remove the EPIRB from the bracket 4 Pull the safety ring...
Страница 37: ...Doc No 87634 Rev G jotron com Page 37 of 48 2 Remove the cover 3 Remove the EPIRB from the bracket...