background image

4

TECHNICAL DATA

RADIATING STOVE

Effect (kW) 

 

3–8

Heating surface (approx. m²) 

 

30–80

Efficiency (approx.%) 

 

82

Weight (kg) 

 

95

Size (HxWxD mm) 

 

855x485x400

Fireplace dimensions  
(HxWxD mm) 

 

300x380x290

Log length (mm) 

 

300–350

Flue dimension (diameter mm) 

 

125

Distance from flammable materials  
(behind, to the side mm) 

 

100, 400

Proof of authorisation  
number 

 

SC1050-13

Norwegian standard 

 

NS 3059

CONVECTION STOVE

Effect (kW) 

 

3–8

Heating surface (approx. m

²

 

30–80

Efficiency (approx.%) 

 

82

Weight (kg) 

 

110

Size (HxWxD mm) 

 

835x500x400

Fireplace dimensions  
(HxWxD mm) 

 

300x380x290

Log length (mm) 

 

300–350

Flue dimension (diameter mm) 

 

125

Distance from flammable materials  
(behind, to the side mm) 

 

100, 300

Proof of authorisation number 

 

SC1050-13 

Norwegian standard 

 

NS 3059

  

SOAPSTONE STOVE

Effect (kW) 

 

3–8

Heating surface (approx. m

²

 

30–80

Efficiency (approx.%) 

 

82

Weight (kg) 

 

240 (95 kg cast iron,  

 

 

145 kg soapstone)

Size (HxWxD mm) 

 

915x615x420

Fireplace dimensions  
(HxWxD mm) 

 

300x380x290

Log length (mm) 

 

300–350

Flue dimension (diameter mm) 

 

125

Distance from flammable materials  
(behind, to the side mm) 

 

100, 300

Cooling time (hours) 

 

6–8

Proof of authorisation  
number 

 

SC1050-13

Norwegian standard 

 

NS 3059

 

IMPORTANT BEFORE YOU GET 

STARTED!

Professional mounting

The manual contains instructions on how to mount 
and install the Oden 6300. To ensure the function and 
safety of the stove, we recommend that installation 
be carried out by a professional. Contact one of 
our resellers who can assist with the installation or 
recommend a suitable technician.

Planning permission

When installing a fireplace and building a chimney, 
planning permission must be applied for with the 
municipality's planning commission. Contact your local 
planning commission if you are unsure of how the 
application works.

Load-bearing foundations

Make sure that the wooden floor joists in your home 
have sufficient bearing capacity for a stove with a 
chimney. Normally, a stove and chimney can be placed 
on standard wooden floor joists in a single-family 
house if the total weight does not exceed 400 kg.

Outer hearth

 

Embers that fall out from the stove can cause fires. If 
you have a flammable floor in front of your stove, it 
must be protected by an outer hearth that covers at 
least 300 mm in front of the door and 100 mm along 
each side. The outer hearth can be made of natural 
stone, concrete, sheet metal or glass, for example. 

The specified safety distances in this manual apply to 
the Swedish market. If the stove is installed in another 
country, local regulations must be met.

WARNING! THE STOVE GETS VERY HOT

When burning, some areas of the stove become very hot and can cause burns if touched. Also, 
be careful with heat radiating through the glass of the door. If flammable material is placed closer 
than the specified safety distance, it can quickly catch fire. Smouldering fires can quickly cause 
gas to ignite, with the risk of injury to persons and property.

NB!

The installation must be inspected by an 
authorised master chimney sweep before 
using the stove.

Содержание Oden 6300

Страница 1: ...Oden 6300 Manual for installation and maintenance A ...

Страница 2: ...imensions and installation 8 9 Soapstone stove dimensions and installation 10 11 Soapstone mounting 12 13 Connection of flues 14 Connect stove to chimney 15 Connect outdoor air to the stove 16 Replaceable parts 17 Maintenance advice 18 How to light the fire correctly 18 Problem solving 19 Warranty Certificate 20 ...

Страница 3: ...ions on how to install your oven as well as maintenance ad vice and tips on the best way to light the fire Don t hesitate to contact us if you have any further questions about using a fire or about your Oden 6300 One book we would recommend for reading in front of the fire is the book WOOD by Lars Mytting A must for everyone with a burning passion Best wishes Josef Davidssons Welcome to the family...

Страница 4: ...t one of our resellers who can assist with the installation or recommend a suitable technician Planning permission When installing a fireplace and building a chimney planning permission must be applied for with the municipality s planning commission Contact your local planning commission if you are unsure of how the application works Load bearing foundations Make sure that the wooden floor joists ...

Страница 5: ...lässig Multiple allocation of the chimney is allowed Tillåten för skorsten med flera eldstäder Standard EN 12815 15a DIN BimschV 1 2 Lesen und Befolgen Sie die Bedienungsanleitung Reading and obeying the operating instructions Läs och följ eldningsinstruktioner i manualen Josef Davidssons Eftr AB Jättevägen 1 333 75 REFTELE Sweden WHAT COMES WITH THE STOVE Make sure all parts are included in the p...

Страница 6: ...ing Anslutningsstos till uteluft Ø 50 mm 400 155 90 55 230 125 765 242 5 Strålningskamin 485 305 242 5 235 855 A ti 230 125 765 242 5 Strålningskamin 485 305 242 5 235 855 A ti 230 125 765 242 5 Primary air damper Air supply damper Radiating stove Here are the most important dimensions required for proper installation and optimal operation All measurements are indicated in millimetres NB Keep in m...

Страница 7: ...ith a density of between 1500 1700 kg m3 and heat conductivity λ 0 6 0 7 W m K as well as a specific heating capacity C of approx 840 J kg K In case of usage of materials other than solid brick contact your local chimney sweep for further information Strålningskamin 400 mm 100 mm 70 mm 70 mm 200 mm 200 mm 430 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 430 mm 300 mm 300 mm Min 950...

Страница 8: ...m 400 155 90 55 210 Konvektionskamin 500 305 250 835 235 125 125 745 250 Uteluftens anslutning Anslutningsstos till uteluft Ø 50 mm 400 155 90 55 210 Konvektionskamin 500 305 250 835 235 125 745 250 Ut Ans till u 155 90 210 Strålningskamin 485 305 242 5 235 855 U An till 1 9 230 125 765 242 5 Outdoor air connection Connectors for outdoor air Ø 50 mm Primary air damper Air supply damper NB Keep in ...

Страница 9: ...100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 345 mm 345 mm 315 mm 315 mm Min 850 mm Min 850 mm Konvektionskamin 300 mm 100 mm 70 mm 70 mm 100 mm 100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 345 mm 345 mm 315 mm 315 mm Min 850 mm Min 850 mm Konvektionskamin 300 mm 100 mm 70 mm 70 mm 100 mm 100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 345 m...

Страница 10: ...STALLATION Here are the most important dimensions required for proper installation and optimal operation All measurements are indicated in millimetres Täljstenskamin Utel Anslu till ute 125 745 307 5 305 307 5 915 835 235 615 100 210 175 Strålningskamin 485 305 242 5 235 855 U An til 9 230 125 765 242 5 Outdoor air connection Connectors for outdoor air Ø 50 mm NB Keep in mind that the outer hearth...

Страница 11: ...mm 100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 380 mm 380 mm 355 mm 355 mm Min 850 mm Min 850 mm Täljstenskamin 300 mm 100 mm 70 mm 70 mm 100 mm 100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 380 mm 380 mm 355 mm 355 mm Min 850 mm Min 850 mm Täljstenskamin 300 mm 100 mm 70 mm 70 mm 100 mm 100 mm 70 mm 70 mm Brännbar vägg Brännbar vägg Brandmur Brandmur 380 mm...

Страница 12: ...ing pins down into the pre drilled holes F front R rear Screw x 2 Soapstone legs x 2 Bottom plate x 1 Top plate x 1 Fireplace x 1 Soapstone top x 1 Soapstone sides x 2 Covering plate outdoor air x 1 Pin x 8 1 2 TIP If you end up making a scratch on the uncoloured soapstone grey you can polish this away with fine grain sandpaper If the coloured soapstone black is scratched or damaged this can be fi...

Страница 13: ...e side stones F front R rear Carefully knock the steering pins with the hammer until they reach the bottom Affix the stove with the screws supplied You may need to adjust the placement of the stove somewhat so that the holes line up with the screws Put the top stone in place The stove is now ready to be connected to the chimney If you have connected outdoor air you should hide the outdoor air tube...

Страница 14: ...On the connector and smoke cover there is a sealing tape and no other sealing material is needed The connectors and the cover are stuck in place with the crosspiece 106300203 Covering ring To be used only for top connection of soapstone model in case of mounting of non insulated flues 106300204 Convection cover Only supplied with the soapstone model For use with rear connection 106300307 Smoke cov...

Страница 15: ...himney The maximum horizontal flue is 1 mm provided that the vertical flue length is at least 5 m It should be possible to sweep the flue throughout its length and the soot doors must be easily accessible Carefully check that the chimney is sealed and that no leakage occurs near the soot doors and smoke connections The stove can be connected to the chimney with several fireplaces 1 2 3 4 Carefully...

Страница 16: ...o to the mechanical ventilation s air vents There are different ways to connect outdoor air to your stove depending on what type of house you live in Some take air directly through the outer wall others go down into the floor and then out through the foundations If you use the foundations it s important that the air supply pipe is insulated to prevent condensation build up Contact your reseller if...

Страница 17: ... the side to loosen it from the grate When re mounting make sure that the grate hinge is stuck fast in the hole on the grate 106300402 Smoke baffle vermiculite 106300208 Top smoke baffle weathering steel 106300401 Smoke baffle vermiculite When mounting the top smoke baffle Take away the vermiculite smoke baffle by lifting it upwards and angling the side vermiculite inwards The top smoke baffle sit...

Страница 18: ...e fireplace Pile up about 1 5 kg of small logs crossways like a log house on top of the briquettes Start by lighting the briquettes These should in turn ignite the wood Keep the fireplace door ajar for the first few minutes until the wood is properly lit Depending on the chimney draught you may need to leave the door open slightly longer to build a temperature in the fireplace and to create a sati...

Страница 19: ...o damp Only dry wood with a maximum moisture content of 20 should be used The damper is overly closed Open the damper to provide more air for combustion The window has turned white Poor combustion Follow the instructions for correct fire lighting provided in this manual Poor quality combustibles for fire lighting Do not use waste wood ground wood impregnated wood laminated plastic plywood or the l...

Страница 20: ... indirect costs or damage The warranty conditions do not apply to glass or the replaceable fireplace parts Warranty period for grates branding iron vermiculite and glass is 1 year Mikael Andersson Owner Warranty Certificate Oden 6300 NB The installation of a fireplace must be reported to the local planning commission The ho meowner is responsible for ensuring that the required safety requirements ...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...TACT Our customer service can offer you personal help and answer your questions Contact us by telephone or email Josef Davidssons Jättevägen 1 333 75 Reftele Tel 46 371 200 01 info josefdavidssons se josefdavidssons se en ...

Отзывы: