Remove all packaging materials before operation. 

1.

 

Observing the correct polarity, install 2 D-cell batteries 
into the battery box and close the lid. 

2.

 

Connect the ‘blue’ and ‘red’ Joolca quick connect fittings 
to the ‘Water Input’ and ‘Water Output’ threads 
respectively. 

3.

 

To connect the showerhead to the shower hose, place 
one of the washers (contained in the pack) into one end 
of the threaded fitting of the hose. Apply Teflon tape to 
avoid leaks and attach the nozzle. 

4.

 

Attach the shower hose to the ‘red’ quick connect fitting 
(water output). 

5.

 

Go over and tighten all hose fittings and connections to 
ensure water tightness. 

 

   

   

   

   

   

   

 

 

 

 

Setting Up 

1

 

2

 

3

 

4

 

Содержание JCA11001

Страница 1: ...ions carefully and understand the operation and safety features of this appliance Familiarise yourself with the appliance before connecting it to the gas container Failure to follow the warnings and i...

Страница 2: ...DESIGNED TO BE USED WITH A SOURCE WATER TEMPERATURE OF 20 C OR BELOW IF THE TEMPERATURE OF THE OUTLET WATER EXCEEDS 50 C THE BURNERS WILL SHUT OFF YOU WILL BE REQUIRED TO TURN THE WATER FLOW OFF AND...

Страница 3: ...m Dimensions 370H x 275W x 165Dmm Weight 4 3kg Approval Number GMK10121 Run Time from 9kg Bottle 15hrs Battery 2 x DD for ignition only Flow Rate 4L 6L Per Minute Max Temp 50 C Max Temp Rise 35 C Min...

Страница 4: ...S ONLY IT MAY BE HAZARDOUS TO ATTEMPT TO FIT OTHER TYPES OF GAS CONTAINERS This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas where...

Страница 5: ...n the cylinder disconnect from the appliance and hold the cylinder in a vertical position then shake from side to side if there is a sound or feel of liquid movement inside the cylinder contains gas W...

Страница 6: ...temperature reaches 50 C To relight the burner you will need to turn the water flow off and back on Water flow sensor Water must be flowing through the system to allow the burner to ignite In the case...

Страница 7: ...fittings to the Water Input and Water Output threads respectively 3 To connect the showerhead to the shower hose place one of the washers contained in the pack into one end of the threaded fitting of...

Страница 8: ...nnect the flexible gas hose to the gas inlet Tighten the connection with a spanner taking care not to over tighten as doing so may damage the assembly 3 Connect the gas regulator to the POL propane ga...

Страница 9: ...nozzle is in the Off position 6 When ready slide the flow regulation switch on the shower nozzle to the On position Water will start to flow 7 Adjust the temperature and flow rate through the shower...

Страница 10: ...l surfaces are cool 2 2 Loosen the connection to the gas cylinder in a clockwise direction and remove 2 3 Using a spanner loosen the connection to the gas inlet in an anti clockwise direction and remo...

Страница 11: ...sure and at least 4LPM to activate the burners There is the possibility of finding some kind of epoxy or debris within the water regulator Check that the water inlet filter screen is clean To flush th...

Страница 12: ...temperature To increase temperature turn the gas regulator control from minimum to maximum and turn the water regulator control from maximum to minimum Check source water temperature If the source wa...

Страница 13: ...at least 4LPM to activate the burners Ensure that the Liquid Propane regulator is correctly threaded to the unit and that there is an adequate amount of gas in the Propane bottle Verify that the incom...