background image

6

JO

NIX

maximate

This instruction manual is an integral part of the device and therefore must be kept 
carefully and must ALWAYS accompany the device, even in the event that it is sold 
to another owner or user or transferred to another facility. In the event that it is 
damaged or lost contact 

JO

NIX

 

S.p.A.

 for another copy or download the document 

from www.jonixair.com.

Repairs and maintenance work must be carried out by 

JO

NIX

 

S.p.A.

 authorised 

staff or by qualified staff according to the provisions set out by this manual. Do not 
alter or tamper with the device as it can lead to hazards and the manufacturer of 
the device shall not be liable for any damage caused.

After removing the packaging check that the contents are intact and complete. In 
the event of a noncompliance please contact the Company that sold you the device.

2 - WARNINGS AND GENERAL PROHIBITIONS

HAZARD:

 It refers to dangerous situations that may result from the use of the device, 

in order to ensure personal safety.

WARNING:

 It refers to integrations or suggestions concerning the proper use of the 

device.

FORBIDDEN:

 This symbol refers to operations that must be avoided under any 

circumstances, and hence forbidden.

HIGH VOLTAGE HAZARD! 

Do not open or remove any doors or protections before disconnecting the voltage 
supply.

WARNING! 

It is mandatory to use protective gloves.

Please pay utmost attention to the following symbols and their meaning. They emphasise specific 
information, such as:

1.3 SYMBOLS 

WASTE FROM ELECTRICAL AND ELECTRONIC EQUIPMENT. 

The crossed-out wheelie bin symbol on the equipment label indicates that the 
equipment is compliant with the Waste Electrical and Electronic Equipment (WEEE) 
Directive. Disposing of the equipment freely in the environment or illegally disposing of 
the equipment are punishable by law.

Содержание maximate

Страница 1: ...MADE IN ITALY JONIX maximate AIR PURIFICATION DEVICE WITH ADVANCED COLD PLASMA TECHNOLOGY USE AND MAINTENANCE MANUAL...

Страница 2: ...IX S p A reserves every right concerning this manual including the right to make any necessary change or improvement to its products and to the manual at any time and without notice It is forbidden to...

Страница 3: ...OPERATING CONDITIONS 10 6 INSTALLATION AND COMMISSIONING 11 6 1 SAFETY STANDARDS 11 6 2 GETTING STARTED 12 6 3 CHOOSING THE INSTALLATION SITE 13 6 4 ELECTRICAL CONNECTIONS 13 6 5 ELECTRIC POWER SUPPLY...

Страница 4: ...filtering module Improper installation of the device and or failure to comply with the instructions in this manual may invalidate the warranty that the Manufacturer issues for its products The Manufa...

Страница 5: ...ce is designed and made to sanitise the air in residential environments that are incompatible with toxic and flammable gases It is therefore strictly forbidden to use the device in environments where...

Страница 6: ...pany that sold you the device 2 WARNINGS AND GENERAL PROHIBITIONS HAZARD It refers to dangerous situations that may result from the use of the device in order to ensure personal safety WARNING It refe...

Страница 7: ...of the device Please note that the use of products that require electricity involves the observance of some crucial safety rules such as When installing commissioning and operating this product it is...

Страница 8: ...s Aureus Abatement 98 Aspergillus Niger Abatement 96 Saccharomyces Cerevisiae Abatement 99 neutral molecule O2 CO2 H2 O gas molecule O2 O3 NO NO2 stable negative ion O O2 O3 The JONIX maximate mobile...

Страница 9: ...13 09 Straight plug 04 Main filter H13 HEPA filter Class EN 1822 ISO 29463 10 Swivel casters with brake 05 Plug centrifugal EC fan n 2 11 Straight connector 06 Secondary filter F7 Fine dust filter Cl...

Страница 10: ...anual Declaration of Conformity Warranty conditions 5 1 PACKAGING Any type of complaint must be sent in writing within eight days from receiving the goods When you receive the device please check all...

Страница 11: ...products used for cleaning and servicing the device you should also observe the recommendations given by the manufacturer of such products Before switching the device on check the integrity of the var...

Страница 12: ...ce work on the device except where specified in this manual Opening or removing the outer casing may expose you to dangerous live parts or may involve other risks All maintenance work must be carried...

Страница 13: ...e electrical connections must be carried out following the instructions provided in this manual Make sure that voltage and frequency of the electric line correspond to those provided on the name plate...

Страница 14: ...ule is ready to work In order to turn on the device act on the selector positioned on the panel turning it to I 6 6 USING THE DEVICE The control and the setting of functions is set using the Display s...

Страница 15: ...show the wear status of the ionisers left or right When the cleaning of the ionizing tubes will be needed or once the bars will be filled to indicate that the ionizing tube has to be replaced an alarm...

Страница 16: ...r intervention is needed this alert state will be shown with the appearance of a notification on the icon of the device part that has caused the alarm Touching the alarm notification the user will be...

Страница 17: ...dule c Maintenance menu quick key to access the module maintenance screen and record the maintenance operation performed 6 8 3 Filters screen replacement becomes necessary ATTENTION this number could...

Страница 18: ...s summary Measured air flow m3 h it is the real time measurement of the air flow of the fan from the appropriate sensor Pressure drop Pa it is the real time measurement of the pressure drop on the fan...

Страница 19: ...otected with password are Device On Off Ionising modules On Off Increase decrease of the fan speed The screens that are protected with password regardless the protection level set are Protection Time...

Страница 20: ...each day of the week it is possible to set up to 4 time slots When time slots are enabled it is not possible change the operating status of the ionising modules or the air flow rate of the fan in thei...

Страница 21: ...f the components but only the recording of the system of the intervention carried out by the user The maintenance procedures are explained in the chapter Maintenance of this manual Ionisers Maintenanc...

Страница 22: ...ned in the chapter Maintenance of this manual Filters Maintenance Maintenance operations on the corresponding filter can be recorded in the system from this menu a Filter H13 b Filter F7 c Filter G4 A...

Страница 23: ...splay b Video allows to view video contents NOTE if multimedia content is not present the icons are obscured User manual Enables to display an extract of the user manual directly from the display a Ke...

Страница 24: ...als the need of maintenance of the modules through an alarm viewed on the display every 7000 hours of operation Filters do not need to be cleaned periodically but will need to be changed when they rea...

Страница 25: ...g the Ionising Tubes Fig 05 Gently unscrew the tubes using the green plastic base If you have trouble first pull off the outer mesh Clean the ionising tubes every time it is shown on the display Fig 0...

Страница 26: ...sing tube needs replacing The tubes must usually be replaced within 18 months of use Fig 08 Wash the mesh under running hot water and dry it thoroughly with a cloth Fig 09 Put the outer metal mesh bac...

Страница 27: ...urface of the tube Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place Otherwise contact the manufacturer Fig 12 Refit the top pa...

Страница 28: ...ponents of the device subject to time deterioration hence they need to be replaced are ionising tubes when signs of wear appear it is necessary to replace the component They are evident with the appea...

Страница 29: ...Open with the handle the front doors Remove the top panel to access the ionising tubes Fig 15 Gently unscrew the tubes using the green plastic base If you have trouble first pull off the outer mesh Fi...

Страница 30: ...s end stop Fig 18 If the operation is difficult to perform pull slightly the earthing spring so that it is not in contact with the surface of the tube Check that the earthing spring is in contact with...

Страница 31: ...unplug the device from the mains and contact qualified staff Failure to clean the ionising tubes when indicated by the device leads to a drop in system performance Register the maintenance operation d...

Страница 32: ...e plug connected to the mains Fig 22 Open with the handle the front doors Remove the top panel to access the filters Fig 20 Type of filters on the JONIX maximate device a Absolute filter H13 b Thin pa...

Страница 33: ...filter locking tabs out Extract the filters Put the new clean filters back in place Push the filter locking tabs towards the device until they click Fig 26 Pull the filter locking tabs out Extract th...

Страница 34: ...with the handle the front doors remove the lower panel to access the filters Fig 29 Unscrew the locking knobs and remove the filter locking bracket Extract the filters Put the new clean filters back...

Страница 35: ...Register the maintenance operation done using the display Reset the alarm launched by the device in the alarm screen Fig 30 Refit the lower panel Turn on the unit by acting on the disconnector On Off...

Страница 36: ...stem detects the need of replacing the tubes for the ionising module The tubes in the ionising module related to the alarm must be replaced Follow the replacement of the ionising tubes procedure in pa...

Страница 37: ...ed at special facilities Please inquire through your municipal authorities as to the location of the eco friendly waste management sites where waste can be received for disposal and its subsequent rec...

Страница 38: ...38 JONIXmaximate ATTACHMENTS EXPLODED JONIX maximate...

Страница 39: ...39 JONIXmaximate 2164 5 205 6 715 715 75 2 1155 75 2 1305 EXPLODED JONIX maximate ambient air ionised air flow...

Страница 40: ...40 JONIXmaximate NOTES...

Страница 41: ...41 JONIXmaximate...

Страница 42: ...42 JONIXmaximate...

Страница 43: ......

Страница 44: ...ters info jonixair com Certified mail jonixsrl legalmail it web www jonixair com Via Tegulaia 10 b 56121 Pisa Italy tel 39 050 985165 Via dell Artigianato 1 35020 San Pietro Viminario PD Italy Tel 39...