(3) 12-Gallon, 300 PSI Carpet Extractor with Heat

2.0  Grounding Instructions Continued

WARNING:

Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified 

electrician or service person if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug 

provided with the equipment. If it will not fit into the outlet, have a proper outlet installed by a qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electrical Code.

3.0   Set-Up / Prepare Unit for Use

DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE INDOORS.

•  All Carpet Extractors, no matter what the time of year, are shipped with antifreeze in the solution lines. Prior to first 

use, fill the tank with one gallon of warm water. Attach the hose and using the hand tool wand, flush out the system by 

spraying the one gallon of water through the pump.

•  Attach the 1-1/2 inch vacuum hose and the brass quick disconnect.
•  Fill the solution tank with warm water (less than 100 degrees Fahrenheit). Fill to approximately 4 inches from the top. 

Use a liquid detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios as directed.

•  Do not use citrus acid, buterol or harsh degreasers inside the machine.

3.1 Power Priming the Solution Pump

Once water is in the solution tank, the solution pump must be primed:

•  Turn ON both vacuums then the solution pump. The vacuum will pull solution through the pump into the vacuum tank.
•  Connect the short prime hose that was included with your machine to the solution outlet quick connect and place the 

open end of priming hose inside the vacuum hose barb.

•  Cup a hand around the hose and barb to increase the 

vacuum suction on the hose. When the pump is primed, 

you will hear the pulsation of the pump change.

•  After priming, turn OFF the solution pump. Disconnect the 

prime hose and connect your solution hose and tool.

If the pump still does not prime or if flow is low or unsteady, 

check the hose from the solution tank to the pump (as well as 

the filter) for clogging, kinks or restrictions. Clean or replace 

hose and/or filter and repeat the priming process.
If you are having trouble with the pump, refer to the “Trouble 

Shooting Guide” section or contact the Jon-Don technical 

support team for advice or assistance.

3.2    Electrical

Plug cord(s) into 20 AMP grounded wall outlet(s). 20 AMP circuits are normally found in kitchens and bathrooms. Never 

remove ground prong from the plug. If a circuit breaker trips during operation, turn machine off, reset the breaker and 

move the electrical cord to a different outlet and resume operation.
If moisture does enter the vacuum motors, contact your local Jon-Don service center. To prevent moisture from damaging 

the vacuum motors during storage, empty the recovery tank and store with the lid open.

Содержание Prospector PE300

Страница 1: ...rmationandSafetyInstructions Register your Machine at www jondon com Serial No 2013 Copy Rights Reserved Jon Don Inc Prospector PE300 Extractor WIth Heat REGISTER YOUR MACHINE ONLINE Reliable Power Innovative Design Safe Easy to Use Powerful Extracting EasyTransport Patented Features Model No PE300 ...

Страница 2: ...rchaser This warranty limits manufacturer s liability for defects in workmanship or materials for replacement of defective parts only The manufacturer accepts no liability for incidental or consequential damages arisen from the use of any equipment defective or not This warranty is in lieu of all expressed or implied warranties and is extended only to the original retail purchaser Manufacturer sal...

Страница 3: ...ect yourself and others from injury when using the machine 2 0 Grounding Instructions DANGER IMPROPER GROUNDING METHOD CAN RESULT IN A RISK OF ELECTRIC SHOCK Electrical equipment must be grounded If the machine should malfunction or breakdown grounding provides a path of least resistance for electrical current to reduce the risk of electric shock The Carpet Extractor is equipped with a cord contai...

Страница 4: ...n Pump Once water is in the solution tank the solution pump must be primed Turn ON both vacuums then the solution pump The vacuum will pull solution through the pump into the vacuum tank Connect the short prime hose that was included with your machine to the solution outlet quick connect and place the open end of priming hose inside the vacuum hose barb Cup a hand around the hose and barb to incre...

Страница 5: ...ter When finished cleaning turn OFF all switches If the auto fill system was used and there is still water in the solution tank push the float down to release the water inlet hose pressure before disconnecting the hose from the faucet Disconnect the water inlet hose from the quick disconnect on the front of the machine Disconnect the solution hose and vacuum hose from the cleaning tool Pull the va...

Страница 6: ...bris and water from being sucked into the vacuum motors Operating the Carpet Extractor without the float assembly or with a poorly maintained assembly will greatly decrease the life of the vacuum motors and will void the warranty If debris builds up on this filter it will reduce the vacuum air flow and may cause a significant decrease in the rate of water recovery If debris prevents the float ball...

Страница 7: ...ze ethylene glycol type Mix well and pour into the solution tank Connect the pressure hose to the female quick disconnect QD on the front of the machine Insert an open ended male QD into the female QD on the end of the pressure hose When primed turn down the pressure to 100 PSI Disconnect the open ended QD and connect the solution hose to the male QD at the auto fill chemical feed connection CAUTI...

Страница 8: ...ectrical System Unit will not Turn On 1 Extension Cord not Plugged In 2 Switch not in the On Position 3 Building Circuit Overloaded 4 Wiring Connections Loose 1 Check if Machine and Cord are Plugged In 2 Check Switches Replace if Necessary 3 Reset Circuit 4 Unplug Machine and Check for Loose Wires Burning Smell 1 Vacuum Motor Hung Up 2 Pump Motor Hung Up 1 Replace Vacuum Motor 2 Replace Pump Pump ...

Страница 9: ... 8 12 Gallon 300 PSI Carpet Extractor with Heat 8 0 Machine Schematic Drawing 2000W Heater Assembly MP 10091025 EA ...

Страница 10: ... Elbow 3 24 10 0804 A Hatch Cover Gasket for Extractor 1 25 10 0804 Hatch Cover for Extractor 1 26 80 0012 Float Assembly for Extract 1 27 10 0416 A 1 1 2 Black ABS Stand Pipe 1 3 28 80 0008 1 5 PVC Female Adapter 1 29 SN 12 RT BLUGRAN 12 Gallon Recovery Tank Blue Granite 1 30 10 0805 Dump Valve for Extractor 1 31 10 0849 1 1 2 ABS Fitting 1 32 10 0155 Hose Cuff Straight 1 33 10 0848 B 1 1 2 90 De...

Страница 11: ...t of 80 0044 S 1 64 80 0080 300 psi Pump 1 65 10 0835 B Pump Bolt for Extractor 4 66 10 0400 D Keeper for Extractor Latch 1 67 10 0832 S R Strap Bolts 4 68 10 0040 3000 psi Blue Hose Part of 80 0040 C 6 69 80 0026 3 8 Barb x 1 4 MPT 90 Degree Part of 80 0040 C 1 70 80 0017 Bulk Head fitting for Extractor 3 71 10 0379 8 32 x 3 8 Screw 8 72 10 0400 C Latch for Extractor 1 73 10 0868 1 4 Female QD fo...

Страница 12: ...Don Inc 2013 Copy Rights Reserved Jon Don Inc 400 Medinah Road Roselle IL 60172 Phone 800 556 6366 Fax 888 344 6878 www jondon com Please fill out the following information Model No Serial No Distributor Name Distributor Phone No Date of Purchase ...

Отзывы: