37
For other alarms not on the list, for persistant problems or for those different from the ones
described above, seek Technical Assistance.
• Lack of electricity
• During normal operation, there was an absence of
electricity for a longer time of the parameter BLACK-
OUT
• Fume probe fails or is not properly connected elec-
trically to the circuit board.
• Fume temperature above a threshold of 260 ° C
• Fan speed does not smoke for the value of set-point.
• Fume fan electrically connected incorrectly.
• Fume fan very dirty or even blocked by deposit or
ash.
• Fan failure.
• The smoke temperature Pr13, is not reached within
the time Pr1.
• Lack of pellets in the drum.
• Basket is very dirty and does not allow the normal
start
• Electrical resistance of power failure.
• Start after the heater has reached the reservoir pel-
let without the initial load.
• The auger gear motor is faulty.
• During THIS FIRE (flame stabilization) the flue gas
temperature is not maintained.
• The Cauldron is positioned incorrectly.
• The smoke Temperature, in the working phase,
decreases to the threshold of Pr 31.
• The flow rate of pellet and / or wind speed smoke in
1st power is not correct to maintain the flame.
• Presence of at least one of two thermostats Security
PELLET tank.
• Intervention of the thermostat tank PELLET 85 ° C,
with manual reset.
• Speech by the tank thermostat pellet, 70 ° C in con-
tact with automatic reset.
• Activation of the security MANOSTAT on the delive-
ry of the smoke exhaust fan, or the tank lid or pellet
stove door is open.
NUMBER ALARM NAME CAUSE AND/OR REASON FOR ALARM SOLUTION
• Control unit main alarms
BLACK OUT
FUME PROBE
FUME HOT
VACUUM
FAILURE
POWER
FAILURE
EMPTY
PELLET
THERMAL SAFE-
TY
LACK
DEPRESS-
AL 1
AL 2
AL 3
AL 4
AL 5
AL 6
AL 7
AL 8
• Check the electrical connection between the socket
on the back of the heater and the connecting cable to
the mains is carried out properly.
• Check that the fuse in the electrical socket is intact.
• Check that the terminals of the electrical wiring of the
heater are well implanted in the unit.
• Make sure it is properly connected, the red wire to +
terminal of the controller and the probe is a thermo-
couple type J.
• Contact the Technical Assistance Center.
• Contact the Technical Assistance Center.
• E 'set an incorrect value to the parameter MAXIMUM
THRESHOLD.
• Visually and manually check that the fan turns freely.
• Check the wiring of the fan and the terminal ENCO-
DER.
• Check the contents of pellets in the tank.
• Check that the pellet feed auger is operating correctly
(press the Menu component from the TEST OUT).
• Check the cleanliness of the basket.
• Check the correct position of the Cauldron.
• Check that the electrical resistance functions (press
the Menu component from the TEST OUT).
• Adjust dosing time and speed pellet extractor hoods
for food and keep the flame properly.
• The Pellet tank is empty, restore the contents.
• Contact Technical Support for flow control and speed
PELLET smoke ventilation.
• Check flow pellets.
• Check the correct position of the sensing element of
the thermostat. (See drawings of the user manual).
• Check the correct setting of the thermostat.
• Adjust the flow of pellet at maximum power, may be
out parameter.
• The flow rates of pellets and smoke extractor fan
speed according to the calorific value of pellets.
• Make sure to clean the chimney -•
Verify the location of the chimney, no special winding
(see user manual)..
• Check if the fan fumes
• Adjust the calibration work in the new limit of work
pressure, ensuring the pull at maximum power.
• Close the door of the tank and pellet stove.