![Johnston VM502 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/johnston/vm502/vm502_maintenance-manual_2025221023.webp)
MA2:3
V Range 502
l
652
l
802 Maintenance Manual
Johnston Sweepers Limited
Chapter - Hydraulic System
Hopper Lower Pressure:
Select option 2 from menu 4.12 and follow the on screen prompts:
Connect a suitable 250 bar gauge to test point H-8Z2 on the discharge system block on the LH side
of the machine in front of the rear wheels. Once connected, acknowledge this by pressing the rotary
encoder on the display.
Start the engine and run at the appropriate speed and acknowledge by pressing the rotary encoder on
the display.
Check pressure and adjust if required relief valve H-9V2 on the discharge system block to 110 bar.
Acknowledge the pressure is set by pressing the rotary encoder on the display.
NOTICE:
Do not run the pressure test for more than 30 seconds.
Powaboom / Rear Wanderhose Option Pressure
Select option 4 from menu 4.12 and follow the on screen prompts:
Connect a suitable 250 bar gauge to test point H-14Z2 on the Powaboom block located on the RHS of
the Subframe rear cross-member. Once connected, acknowledge this by pressing the rotary encoder
on the display.
Start the engine and run at the appropriate speed and acknowledge by pressing the rotary encoder on
the display.
Check Hydraulic Pressure Powaboom
Check and adjust if required relief valve H-14V2 (See Hydraulic Circuit Sheet 10 C-3)
Acknowledge the pressure is set by pressing the rotary encoder on the display.
Reconnect the hydraulic hose.
Sweeping System
Supawash / Front Brush Option Pressure:
First remove the hose from port MA on the Supawash block located on the LHS of the Subframe in front
of the centre cross-member. Plug port MA and plug the end of the hose.
Select option 3 from menu 4.12 and follow the on screen prompts:
Connect a suitable 250 bar gauge to test point H-12Z2 on the Supawash block. Once connected,
acknowledge this by pressing the rotary encoder on the display.
Start the engine and run at the appropriate speed and acknowledge by pressing the rotary encoder on
the display.
Check pressure and adjust if required relief valve H-12V2 on the Supawash block to 220bar.
Acknowledge the pressure is set by pressing the rotary encoder on the display.
Reconnect the hydraulic hose.
NOTICE:
Do not run the pressure test for more than 30 seconds.
NOTICE:
Do not run the pressure test for more than 30 seconds.
Содержание VM502
Страница 2: ...V Range 502 l 652 l 802 Maintenance Manual...
Страница 20: ...V Range 502 l 652 l 802 Maintenance Manual MA1 18 Chapter Scheduled Maintenance...
Страница 36: ...V Range 502 l 652 l 802 Maintenance Manual MA2 16 Chapter Hydraulic System...
Страница 158: ...V Range 502 l 652 l 802 Maintenance Manual MA5 22 Chapter Pneumatic System Littasnatch Option Sheet 14 17 Rev K...
Страница 162: ...V Range 502 l 652 l 802 Maintenance Manual MA5 26 Chapter Pneumatic System...
Страница 170: ...V Range 502 l 652 l 802 Maintenance Manual MA6 8 Chapter Wearing Items...
Страница 188: ...V Range 502 l 652 l 802 Maintenance Manual MA7 18 Chapter Remove and Refit Procedures...
Страница 204: ...V Range 502 l 652 l 802 Maintenance Manual MA8 16 Chapter Fault Diagnosis...
Страница 212: ...V Range 502 l 652 l 802 Maintenance Manual MA9 8 Chapter Service Tools...
Страница 220: ...V Range 502 l 652 l 802 Maintenance Manual MA10 8 Chapter Health and Safety...