![Johnston VM502 Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/johnston/vm502/vm502_maintenance-manual_2025221140.webp)
V Range 502
l
652
l
802 Maintenance Manual
MA5:4
Chapter - Pneumatic System
M02MA-024-2
ENSURE BOTH DIALS
ARE SET TO 9
A
B
B
D
H
F G
C
E
STATUS
INDICATORS
(see page MA5:5)
Air Filtration and Regulator (FR)
A filter regulator unit, located in the systems locker filters the air for the sweeper section of the pneumatic
system to prolong the life of the components served by it.
Before carrying out any major work on the unit it will be necessary to remove it from the locker by first draining
the vehicle air system, then disconnecting the supply pipes and releasing the fixing bolts.
Pneumatic Valve Island
The pneumatic valve island is a modular unit comprising various segments. Each segment has an indicator
LED that illuminates when energised
(A)
and a manual override button
(B)
for ports 2 or 4 on each segment
Each segment is identified by a unique code, they are not all the same.
(see page 5:6 for identification and functionality)
To replace a valve segment -
1) Isolate the vehicles electrical supply.
2) Isolate the pneumatic system using the isolation tap on the filtration unit.
3) Disconnect the two electrical connectors.
4) Remove the 4 fixing screws
(C)
.
5) Remove the 4 socket head screws
(D)
.
6) Remove the valve cover containing the valve operating coils
(E)
.
7) Unscrew
(F)
each side of the segment to be replaced.
8) Fold open the segment (
G
) and replace ensuring the rubber gasket
(H)
is in position.
9) Tighten screws
(F)
.
10) Replace top cover
(E)
.
11) Replace screws
(D)
.
12) Re-connect the electrical connectors
COMPONENT REMOVAL
Содержание VM502
Страница 2: ...V Range 502 l 652 l 802 Maintenance Manual...
Страница 20: ...V Range 502 l 652 l 802 Maintenance Manual MA1 18 Chapter Scheduled Maintenance...
Страница 36: ...V Range 502 l 652 l 802 Maintenance Manual MA2 16 Chapter Hydraulic System...
Страница 158: ...V Range 502 l 652 l 802 Maintenance Manual MA5 22 Chapter Pneumatic System Littasnatch Option Sheet 14 17 Rev K...
Страница 162: ...V Range 502 l 652 l 802 Maintenance Manual MA5 26 Chapter Pneumatic System...
Страница 170: ...V Range 502 l 652 l 802 Maintenance Manual MA6 8 Chapter Wearing Items...
Страница 188: ...V Range 502 l 652 l 802 Maintenance Manual MA7 18 Chapter Remove and Refit Procedures...
Страница 204: ...V Range 502 l 652 l 802 Maintenance Manual MA8 16 Chapter Fault Diagnosis...
Страница 212: ...V Range 502 l 652 l 802 Maintenance Manual MA9 8 Chapter Service Tools...
Страница 220: ...V Range 502 l 652 l 802 Maintenance Manual MA10 8 Chapter Health and Safety...