E2 –
Elevation Out Of Range
Error 2
Step 1. Calibrate Elevation
Calibrate the elevation as outlined in the System Calibration Procedure in below step.
Step 2. CORRECTIVE ACTION
1.Check the failed system with a known good console cable. If fixed then
repair/replace the console cable.
2.Check the failed system with a known good elevation motor. If problem fixed then
repair/replace the elevation motor.
3.Check the failed system with a known good interface board. If problem fixed then
repair/replace the interface board (MCB).
4.Check the failed system with a known good console board with current software. If
the problem is fixed then repair/replace the console.
Enter engineer mode of
“MANUAL
CALIBRATION”
screen
Check the “P13 ELV
DIRECTION” screen
whether set to “Yes”
Set to “Yes”
AUTO-
Calibration
Enter the “P4 ELEVATION
MINIMUM” screen
whether parameter set is
30 2
AUTO-
Calibration
Enter the “P5
ELEVATION
MAXIMUM ” screen
whether parameter set is
240 5
AUTO-
Calibration
Содержание Vision T9800HRT
Страница 1: ...1 Vision T9800HRT Service Manual...
Страница 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Страница 9: ...9 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Страница 16: ...16 T9800 TM87 Electrical block diagram for 110V...
Страница 17: ...17 T9800 TM87 WIRING DIAGRAM INSTRUCTION for 110V...
Страница 18: ...18 T9800 TM87 Electrical block diagram for 220V...
Страница 19: ...19 T9800 TM87 WIRING DIAGRAM INSTRUCTION for 220V...
Страница 20: ...20 SECTION 3 CONSOLE FUNCTIONAL FLOW DIAGRAM...
Страница 21: ...21 OPERATING T9800...
Страница 27: ...27 SECTION 4 MCB LED INSTRUCTIONS...
Страница 28: ...28 AC FAN...
Страница 30: ...30 SECTION 5 TROUBLESHOOTINGS...