Treatment:
•
First, rule out that the internal thermal protection of motor is caused by long-time operation
•
Use manual mode to force the motor to start, checking if it can be started.
•
Enter P2 (refer to2-2) to check if the SENSOR corresponding to the poor motor triggers the limit,
For example, when the front and back machine core motors cannot move forward, it is required
to note that if the front limit lamp signal is triggered; when the front limit lamp is on, it represents
that the lower control panel thinks that the machine core is at its foremost position and cannot go
more forward
4-7.
Machine core motor
Machine core motor
does not work
does not work
Sensor mode
Machine core forward
and backward