background image

363714-UTG-D-0210

2

Johnson Controls Unitary Products

Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.

LEFT SIDE

RIGHT SIDE

.5”

.5”

RETURN END

B

24.25”

29.5”

28.5”

Electrical
Entry

Gas Pipe
Entry

Thermostat
Wiring

FRONT

14”

1”

1.5”

23”

SUPPLY END

C

24.38”

20”

.5”

B

Gas Pipe
Entry

Thermostat
Wiring

33”

A

.5”

Electrical
Entry

Vent Connection
Outlet

Vent
Connection
Outlet

4” Diameter

Outlet

Vent Connection

Cabinet and Duct Dimensions

Models

Nominal

CFM (m

3

/min)

Cabinet

Size

Cabinet Dimensions (Inches)

Approximate

Operating Weights

A

B

C

Lbs

GG(8,L)S040A08MP11

800

A

14 1/2

13 3/8

10.3

89

GG(8,L)S060A10MP11

1000

A

14 1/2

13 3/8

10.3

91

GG(8,L)S060A12MP11

1200

A

14 1/2

13 3/8

10.3

94

GG(8,L)S080B12MP11

1200

B

17 1/2

16 3/8

11.8

103

GG(8,L)S080C16MP11

1600

C

21

19 7/8

13.6

114

GG(8,L)S080C22MP11

2200

C

21

19 7/8

13.6

119

GG(8,L)S100B12MP11

1200

B

17 1/2

16 3/8

11.8

108

GG(8,L)S100C16MP11

1600

C

21

19 7/8

13.6

118

GG(8,L)S100C20MP11

2000

C

21

19 7/8

13.6

122

GG(8,L)S120C16MP11

1600

C

21

19 7/8

15.8

123

GG(8,L)S120C20MP11

2000

C

21

19 7/8

15.8

129

GG(8,L)S130D20MP11

2000

D

24 1/2

23 3/8

17.5

135

Ratings & Physical / Electrical Data

Models

Input

Output

AFUE

Air Temp. 

Rise

Max. Outlet

Air Temp

Blower

Blower 

Size

Max 

Over-Current 

Protect

Total Unit

Amps

Min. wire Size 

(awg) @ 75 ft 

one way

MBH

MBH

°F

°F

HP

Amps

GG(8,L)S040A08MP11

40

32

80.0

25-55

155

1/5

2.1

9 x 8

10

4.5

14

GG(8,L)S060A10MP11

60

48

80.0

25-55

155

1/3

3.8

9 x 8

10

6.0

14

GG(8,L)S060A12MP11

60

48

80.0

30-60

160

1/3

4.8

11 x 8

10

7.0

14

GG(8,L)S080B12MP11

80

64

80.0

35-65

165

1/3

4.8

11 x 8

10

7.5

14

GG(8,L)S080C16MP11

80

64

80.0

25-55

155

1/2

7.5

11 x 10

15

10.0

14

GG(8,L)S080C22MP11

80

64

80.0

25-55

155

1

14.5

11 x 11

20

16.0

12

GG(8,L)S100B12MP11

100

80

80.0

40-70

170

1/3

4.8

9 x 8

10

7.5

14

GG(8,L)S100C16MP11

100

80

80.0

35-65

165

1/2

7.5

11 x 10

15

10.0

14

GG(8,L)S100C20MP11

100

80

80.0

25-55

155

1

14.5

11 x 11

20

17.0

12

GG(8,L)S120C16MP11

120

96

80.0

40-70

170

1/2

7.5

11 x 10

15

10.0

14

GG(8,L)S120C20MP11

120

96

80.0

30-60

160

1

14.5

11 x 11

20

17.0

12

GG(8,L)S130D20MP11

130

104

80.0

35-65

165

1

14.5

11 x 11

20

17.0

12

Содержание GG(8,L)S120C20MP11

Страница 1: ...ontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable opera tion Low unit amp requirement for easy replacem...

Страница 2: ... 8 L S100B12MP11 1200 B 17 1 2 16 3 8 11 8 108 GG 8 L S100C16MP11 1600 C 21 19 7 8 13 6 118 GG 8 L S100C20MP11 2000 C 21 19 7 8 13 6 122 GG 8 L S120C16MP11 1600 C 21 19 7 8 15 8 123 GG 8 L S120C20MP11 2000 C 21 19 7 8 15 8 129 GG 8 L S130D20MP11 2000 D 24 1 2 23 3 8 17 5 135 Ratings Physical Electrical Data Models Input Output AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Max Over Curr...

Страница 3: ...e return with a transition to allow use of a 20x25 filter Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer s rec ommendation and a transition is used to allow use on a 20x25 filter NOTICE Recommended Filter Sizes CFM Cabinet Size Side in Bottom in 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x ...

Страница 4: ...rator coil where the combustible floor base kit provides access for combustible airflow 1CB0514 For 14 1 2 cabinets 1CB0517 For 17 1 2 cabinets 1CB0521 For 21 cabinets 1CB0524 For 24 1 2 cabinets EAC Transition Kits For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage 1TK1001 For a...

Страница 5: ...0 2448 2339 2224 2111 1974 1831 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 GG 8 L S100B12MP11 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 64...

Страница 6: ...1192 1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 GG 8 L S080C22MP11 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 GG 8 L S100B12MP11 High 1258 1278 12...

Отзывы: