15
Each cylinder must be checked to guarantee it is safe,
particularly when it is refilled at an authorised refil-
ling station. Always use a certified pressure regulator
connected to the cylinder.
Connect the tube to the regulator rubber support and
that of the appliance and fasten it with the tube fa-
stening ties.
- The flexible tube should be replaced on the expiry
date on it.
- The flexible tube can be dismantled to avoid sub-
jecting it to traction or torsion force and it does not
have narrow curves or choke points.
- Periodically check the wear status of the flexible tube
and in case of leaks, do not repair, but replace it.
- When installation is complete, check the joints are
perfectly sealed, spreading a soapy solution over
them for this purpose and checking no bubbles form.
NEVER USE FLAMES TO CHECK THE JOINTS ARE SEA-
LED.
The tube to use should be suitable based on the sa-
fety standards in force; check it is sound, check the
expiry and periodically replace it.
ATTENTION: Assembly and periodic controls of the
flexible tube should be carried out by qualified and
certified staff.
Gas leak testing
If you suspect a leak, close the gas supply on the re-
gulator. Dismantle the regulator from the cylinder
and remove the cylinder from the product outdoors.
DO NOT USE the product until it was checked by
competent staff.
Carry out gas leak testing at least once a year and
Содержание Gas 3
Страница 1: ...Cucina a gas a 3 fuochi ISTRUZIONI D USO Gas cooker with 3 plates INSTRUCTIONS FOR USE Gas 3 ...
Страница 2: ...2 Fig 1 L M N O A B P F C G D H E ...
Страница 19: ......