background image

2

Operation

next time,just press ON/OFF button and unit will run in previous status.

Remote controller can memorize each operation status. When starting it 

2.Select operation mode

Press FAN SPEED button. For each press, fan speed

follows:

Press MODE button. For each press, operation mode
changes as follows:

Remote controller:

Remote controller:

Press

button

Every time the button is pressed, temp.setting
increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will decrease

rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.

LOW

MED

HI

AUTO

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

TEMP+

TEMP-

TEMP+

TEMP-

Base  Operation

Remote controller

   Air Flow Direction Adjustment

Vertical flap

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

(Auto swing)

1.Status display of air flow

When restart after remote turning off, the remote 

         memorize the previous 

Move the vertical blade by a knob on air

to adjust left and right direction referring to Fig.

2.Left and right air flow adjustment(manual)

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

adjusted to left or 

It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY

otherwise, condensate water might occur.

conditioner

Emergency Operation:

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice,

release

Test operation switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Emergency operation and test operation

 Use this operation only when the remote controller
 is defective or lost.

When the emergency operation switch is
pressed,the" Pi "sound is heard once, which 

the start of this operation.

In this operation, the system automatically selects

the operation modes,cooling or fan or heat,
according to the room temperature.

.

It is not possible to operate in dry mode.

Room

temperature

Operation

   mode

Designated

temperature

Timer

mode

Air flow

ABOVE 23

O

C

BELOW 23

O

C

COOLING

HEAT

23

O

C

26

O

C

NO

NO

AUTOMATIC

AUTOMATIC

cooling only

 

Room  temperature

Operation

   mode

Designated

temperature

Timer

mode

Air flow

BELOW 23

O

C

FAN

26

O

C

NO

AUTOMATIC

at air outlet if all vertical louvers are 

right.

mode ,

controller will automatically

Note:

set swing position.

means

changes as

Pi

Pi Pi

AUTO

COOL

DRY

FAN

HEAT

 Operation

  Mode

AUTO

 

e

t

o

m

e

R

 

 

r

e

ll

o

r

t

n

o

C

 

  Note

COOL

 

DRY

 

HEAT

 

 FAN

 

In DRY mode, when room temperature becomes
lower than temp.2

o

C,unit will run intermittently

at LOW speed regardless of FAN setting.

Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.

air conditioner automatically adjusts the fan speed 

temperature.

When FAN is set to AUTO, the 

according to room

In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.

 Display 

 Board

Содержание YORK YH9FZC09BAH-AFX

Страница 1: ...USER S MANUAL High Wall Fixed R 410A 60Hz YH9FZC09 12 18 24BAH AFX Read this manual before installation and operation Make sure that it is well kept for later reference ...

Страница 2: ...Setting temp display 2 3 Operation mode indicator White light for COOL DRY mode Green light for health function 1 2 3 5 8 5 6 4 7 front panel Front panel Horizontal louver Air Filter inside 7 Adjust up and down air flow Don t adjust it manually Vertical blade Adjust left and right air flow 1 ...

Страница 3: ...ion Use this switch in the test operation when the room normal operation your finger from the switch the cooling Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release Test operation switch is the same as emergency switch operation starts with the air flow speed Hi Emergency operation and test operation Use this operation only when the remote ...

Страница 4: ...s in corresponding sleep mode adapted to the automatically selected operation mode O C O C 1 POWER Operation 2 SOFT Operation Press POWER SOFT button again POWER or SOFT disappears To cancel POWER or SOFT operation Note When you need rapid heating or cooling you can use this function In COOL mode fan speed automatically takes high speed of AUTO fan mode In HEAT mode fan speed automatically takes m...

Страница 5: ...etely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the controller with a dry cloth Do not use glass cleaner or chemical cloth Gasoline benzine thinner or cleanser may damage the coating of the unit Hot water over 40 O C 104 O F may cause discoloring or deformati...

Страница 6: ...t try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fire...

Страница 7: ...ect the air conditioner immediately until 3 minutes have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit ...

Страница 8: ...2015 Johnson Controls Inc www johnsoncontrols com Doc No UH9FZCAH 151103 ...

Отзывы: