Trouble shooting
Normal
Performance
inspection
Noise is heard
Phenomenon
Cause or check points
The system
immediately.
Smells are
generated.
Mist or steam are
Multiple
check
Poor cooling
When unit is stopped, it won't restart
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop,
a swishing or gurgling noise may
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
temperature changes.
Should there be a big noise from
filter may be too dirty.
This is because the system
circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly?
Are there some doors or
Is there any direct sunlight
through the window during the
Are there too much heat sources
or too many people in the room
In dry mode, fan
speed can’t be
changed.
In DRY mode, when room temperature
2
o
C,unit will run
regardless of FAN setting.
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned
every 15 days.
intermittently at LOW speed
becomes lower than temp.
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture,
paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
Cautions
3. If the fuse of indoor unit on PC board is
it with the type of T. 3.15A/ 250V
outdoor
broken,change it with the type of T.25A/250V
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and swing louver.
Do not allow children to play with the air conditioner
case should children be allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proo f.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following situation
The power plug and connecting cable
acquired the local
2. If the power supply cord is damaged, it must be replaced
manufacturer
qualified
person.
4. The wiring method should be in line with
the local wiring
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
7. The appliance is not intended for use
persons
without supervision.
8. Young children should be supervised
with
the appliance.
9. Please employ the proper power plug,
cord.
11.In order to protect the units,please turn
30 seconds
later, cutting off the power.
10.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32
o
C/23
o
C
24
o
C/18
o
C
o
C/-8
o
C
46
o
C/26
o
C
18
o
C
27
o
C
21
o
C/15
o
C
Outdoor
Maximum:D.B/W.B
Minimum:D.B
24
o
C/18
o
C
-15
o
C
(INVERTER)
o
C
7
-
Minimum:
Minimum:
grille of the air
or any other things into the
.In no
or its service agent or a similar
broken,please
. If the fuse of
standard.
by young children or
to ensure that they
which fit into the
must have
off the A/C first,
Before asking for service, check the following
first.
blown out.
does not restart
by the
change
unit is
infirm
do not play
power supply
attestation.
and at least
15
Exponent
Domestic Air Conditioner
62
Содержание York FREE MATCH EK-Series
Страница 15: ...Connector Wiring Diagram 13 Domestic Air Conditioner PCB 2 CN1 CN5 CN6 CN7 CN10 CN11 CN8 CN9 CN2 CN3 CN4 ...
Страница 70: ...WARNING CAUTION 68 Installation ...
Страница 76: ...74 Installation ...
Страница 79: ...Pressurize for over 3 minutes at 4 2MPa After above 77 Installation ...
Страница 83: ...81 Domestic air conditioner Removal of procedure 9 ...
Страница 86: ...84 Domestic air conditioner Removal of procedure three 3 HOOKS ...
Страница 87: ...85 Domestic air conditioner Removal of procedure horizontal flap flap flap flap flap ...
Страница 89: ...87 Domestic air conditioner Removal of procedure ...
Страница 90: ...Domestic air conditioner Removal of procedure 3 88 ...
Страница 91: ...Domestic air conditioner Removal of procedure 89 ...
Страница 92: ...Domestic air conditioner Removal of procedure 90 ...
Страница 93: ...Domestic air conditioner Removal of procedure Outdoor Unit Removal of Outdoor Panel 91 ...
Страница 94: ...92 Domestic air conditioner Removal of procedure Loosen the top panel screws 1 2 Lift the top panel ...
Страница 95: ...93 Domestic air conditione Removal of procedure Loosen the csrews and pull the panel ...
Страница 97: ...95 Domestic air conditioner Removal of procedure ...
Страница 98: ...96 Domestic air conditioner Removal of procedure ...
Страница 99: ...97 Domestic air conditioner Removal of procedure 2 Loosen the fixing screws and remove the motor ...
Страница 100: ...98 Domestic air conditioner Removal of procedure ...
Страница 101: ...99 Domestic air conditioner Removal of procedure and remove the reactor Loosen the screw ...
Страница 102: ...100 Domestic air conditioner Removal of procedure Loosen the marked screws and pull out the backgurd ...
Страница 110: ...The end ...