Service Diagnosis
8.4.6 Over-current of the compressor
Outdoor Display
LED1
flash
3 or 24 or 25 times
Method of
The current of the compressor is too high
Malfunction
Detection
Malfunction
when the IPM Module is damaged
Decision
or the compressor
is damaged
Conditions
power supply. voltage is too low or too high
Supposed
Ŷ
Faulty
IPM Module
Causes
Ŷ
Faulty
compressor
Ŷ
Faulty
power supply
Troubleshooting
* Caution
Be sure to turn off power switch before connect or disconnect connector, or
parts damage may be occurred.
Electrify the machine again and turn it on
with the remote controller,If malfunctions
are
reported
before
or
upon
the
compressor being started up,
IPM Module is damaged and
needs replacing.
Repair the power supply
the system may have been over or under
charged with gas, which can be judged through
the pressure of the measuring system.
YES
NO
Yes
NO
The compressor is started normally,
but malfunctions are reported after it
has run for some time. Check the
power supply is too low or too high
NO
72
Domestic Air Conditioner
YJHJZH018BARRAFX
-SM
Содержание YJHJXH018BARR-FX
Страница 41: ...39 YJHJZH018BARRAFX SM ...
Страница 54: ...WARNING CAUTION Installation Domestic air conditioner 52 Safety Precautions YJHJZH018BARRAFX SM ...
Страница 55: ...Installation Domestic Air Conditioner 53 Safety Precautions YJHJZH018BARRAFX SM ...
Страница 57: ...Installation 55 Domestic Air Conditioner Safety Precautions YJHJZH018BARRAFX SM ...
Страница 58: ...Installation Domestic Air Conditioner 56 Read Before Installation YJHJZH018BARRAFX SM ...
Страница 59: ...Installation Domestic Air Conditioner 57 Read Before Installation YJHJZH018BARRAFX SM ...
Страница 60: ...Installation Domestic Air Conditioner 58 Read Before Installation YJHJZH018BARRAFX SM ...
Страница 63: ...Installation Domestic Air Conditioner 61 Installation Procedure Air Tightness Test YJHJZH018BARRAFX SM ...
Страница 64: ... e g 1U18EN2ERA Installation Domestic air conditioner 62 YJHJZH018BARRAFX SM ...
Страница 82: ...Removal Procedure Removal of indoorunit 80 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 83: ...81 Domestic Air Condiioner YJHJZH018BARRAFX SM ...
Страница 85: ...three two Removal Procedure HOOKS 83 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 86: ...flap flap flap flap Removal Procedure 84 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 87: ...Removal Procedure 85 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 88: ...Removal Procedure 86 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 89: ...Removal Procedure 87 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 90: ...Removal Procedure 88 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 91: ...Removal Procedure 89 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 92: ...Removal Procedure 90 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 93: ...Removal Procedure 91 Domestic Air Conditioner YJHJZH018BARRAFX SM ...
Страница 104: ...102 Domestic air conditioner Removal of procedure s t n i o P e r u d e c o r P p e t S 2 YJHJZH018BARRAFX SM ...
Страница 105: ...103 Domestic air conditioner Removal of procedure s t n i o P e r u d e c o r P p e t S 3 YJHJZH018BARRAFX SM ...
Страница 112: ...The end Sincere Forever YJHJZH018BARRAFX SM ...