TECHNICAL SPECIFICATIONS 

 

Model

 

VCC-64

 

Power supply

 

12V DC

 

Consumption

 

1.2W max (100mA)

 

Bus RS-485

 

Max. distance 1000m/ 3280,8 ft. (Max. 8 VCC-64 connected by 

bus)

 

Address

 

Dip-switch 3 bit

 

Volume Buttons

 

VOL- / VOL+

 

Volume Steps

 

0-9

 

Source Buttons

 

CH+ / CH-

 

Channel Range

 

64 / 01 BGM + MIC LOCAL

 

Functioning Conditions

 

-5ºC to +45 ºC /23 ºF to 113 ªF 

5% to 95% Relative Humidity (without condensation)

 

Finishing

 

ABS RAL 9016

 

Weight

 

110gr 3,88 oz

 

Drill Installation (HXWXD)

 

62mm x 70mmx 35mm / 2,44” x 2,75 x 1,38

 

Dimensions (HxWxD)

 

86mm x 86mm x45mm / 3,38 x 3,38 x 1,77

 

Table 5 - Technical Specification 

 

LIST OF ILLUSTRATIONS 

Figure 1 - Connections ............................................................................................................... 6

 

Figure 2 - Cabling ...................................................................................................................... 8

 

 

 

LIST OF TABLES 

Table 1 - Active Mode ................................................................................................................ 5

 

Table 2 - Active Mode Display .................................................................................................... 5

 

Table 3 - Connections ................................................................................................................ 7

 

Table 4 - Bus Addresses ............................................................................................................ 7

 

Table 5 - Technical Specification ............................................................................................... 9

 

 

 

 

 

Содержание VCC-64

Страница 1: ...ler VCC 64 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Tyco Fire Securit...

Страница 2: ...d for several days disconnect the power supply to prevent damage from overloading Never pour liquid into the openings this could cause fire or electric shock Never open the equipment For safety reason...

Страница 3: ...atic Lock 6 2 2 Connection to the System 6 2 2 1 Data Bus and Power Supply 6 2 2 2 Bus Address 7 2 2 3 Cabling 7 3 PROBLEM SOLVING 8 3 1 Blank Screen 8 3 2 The Number of Sources and Volume Does Not Ap...

Страница 4: ...0 steps per change Automatic lock function It shows the identifier of the music source routed to the zone It shows the volume level assigned to the zone Lock activated indicator Connection of devices...

Страница 5: ...tons CH and CH The display will show the change in the number of the source The number displayed corresponds to the number of the source in the PA system The audio source in the zone of the VCC 64 can...

Страница 6: ...VCC 64 has two poles for data connection through RS 485 protocol It has a power supply input of 12V DC with a consumption of 1 2W 100mA The connector is marked as J500 When the equipment has a power...

Страница 7: ...connection port for integration RS 485 Terminal D Port D Standard RS 485 9600 8 SPACE 1 Table 3 Connections 2 2 2 Bus Address The VCC 63 has a DIP Switch to configure the address in the RS 485 bus Eve...

Страница 8: ...nd therefore will not work properly 3 2 The Number of Sources and Volume Does Not Appear on Screen If the number of sources and volume does not appear on screen this is an indication to the system tha...

Страница 9: ...VOL Volume Steps 0 9 Source Buttons CH CH Channel Range 64 01 BGM MIC LOCAL Functioning Conditions 5 C to 45 C 23 F to 113 F 5 to 95 Relative Humidity without condensation Finishing ABS RAL 9016 Weig...

Отзывы: