1083286-UIM-L-1219
38
Johnson Controls Ducted Systems
SECTION XIII: WIRING DIAGRAM
FIGURE 38:
Wiring Diagram
POWER SUPPLY 115-1-60
GND
CONDENSATE
C
PS3
NO
ROS1
WHT
PS1
C
NO
RED/BLK
ROS1
HI
C
M
GAS VALVE
CONTROLS
TO AIR CONDITIONER
ROOM THERMOSTAT
2-STAGE COOLING
2-STAGE HEATING
COMMON T'STAT CONNECTION
Y2
Y
W1
W
R
C
G
Y1
W2
W2
Y1
G
C
R
W
W1
Y
Y2
HIGH
LOW
IDM
EAC
HUMIDIFIER
GND
C
NO
HS1
DS
NO
PS1
C
C
PS2
NO
GND
COM
115V
24V SEC
PRI
1T (40VA)
1ST STAGE
2ND STAGE
LS
ROS2
RED/WHT
C
NO
GRY
3
2
1
WHT
RED
BLK
GRN
IDM
GAS VALVE
BLK
WHT
BLK
ORN
PS2
M
C
HI
YEL
WHT
RED/GRN
RED
FLAME SENSOR
BRN
ORG/BLK
C
PS3
NO
LS
PRP
BLU
GRY
BRN
WHT
RED
WHT
NO
C
DS
115VAC LINE
24V SEC
LOAD
115V PRI
LINE
115VAC NEUT.
ROS2
BLK
2
1
BLK
BLK
WHT
WHT
HSI
RED
GND
EAC
HUM
HI COOL
XFMR
LO HEAT
FURNACE CONTROL
5
4
3
2
CONT
1
4
1
2
3
6
5
9
8
11
10
7
12
C
G
R
W1
Y/Y2
Y1
W2
NEUTRALS
BLU - MED HI
GRN
BRN
BRN
GND
BLK - HI
YEL - MED LOW
RED - LOW
WHT
MOT
MOT
COOL
HEAT
EAC
LINE
LO COOL
HUM
HI HEAT
SEE NOTE 2
CAP
CAP
Wiring Diagram - 96% Two-Stage PSC Furnace
Flashes
Diagnostic Fault Codes
Fault Condition
Power Off or blown fuse
Normal Operation
Normal Operation with call for heat
Control Failure
Low flame sense current
Y signal with no G from thermostat
Flame present with gas off
Check pressure switch wiring
Vent, intake, OR termination problem
Airflow problem OR open fuse
Flame Rollout OR open fuse
Repeated 3 Red
Failed to light burners
Loss of flame during call for heat
Hot/Neutral reversed OR poor
ground/neutral OR Twinning error
Gas valve shorted "ON"
Check blower motor/wiring
Vent, intake, OR termination problem
None
Slow Green
Slow Amber
Steady on Red
Rapid Amber
4 Amber
1 Red
2 Red
3 Red
4 Red
5 Red
6 Red
7 Red
8 Red
9 Red
10 Red
11 Red
13 Red
SERVICING THIS UNIT
OPEN ALL DISCONNECTS BEFORE
CAUTION
PRECAUTION
OUVREZ LES DISJONCTEURS AVANT
DE PROCEDER AVEC LE SERVICE
1042426-UWD-A-0413
Fault Code Retrieval
To retrieve fault codes, push and release ERROR button on control board. The LED will flash the
last five error codes, beginning with the most recent. If there are no fault codes in memory, the LED
will give two green flashes. To clear the fault code memory, push and hold the ERROR button for
at least five seconds. The LED will give three green flashes when the memory has been cleared.
Notice - Only a qualified service technician should use this feature.
Fault code retrieval functions will work only if there are no active thermostat signals.
NOTES:
1. Si l'un des fils d'origine fourni avec ce four doit être remplacé, il doit être
remplacé avec le fil ayant un degré de température d'au moins
221 degrés F (105 degrés C ).
2. Les connexions à grande vitesse du moteur du ventilateur indiqués sont
typiques, mais peuvent varier selon le modèle et par application.
NOTES:
1. If any of the original wire as supplied with the furnace must be replaced,
it must be replaced with wiring material having a temperature rating of
at least 221 degrees F (105 degrees C ).
2. Blower motor speed connections shown are typical, but may vary by
model and application.
DS -
ROS -
TST -
PS1 -
PS2 -
PS3 -
MOT -
IDM -
CAP -
HSI -
LS -
HUM -
XFMR -
GV -
EAC -
Legend
Door switch
Rollout switch
Wall thermostat
Pressure switch 1 Stage
Pressure switch 2 Stage
Pressure switch Condensate
Circulating motor
Inducer motor
Capacitor
Hot surface igniter
Limit switch
Humidifier
Transformer
Gas valve
Electronic air cleaner
DS -
ROS -
XFMR -
LS -
HSI -
PS1 -
PS2 -
PS3 -
MOT -
IDM -
GV -
HUM -
TST -
CAP -
EAC -
Legende
Commutateur de porte
Commutateur de roulement
Transformeur
Commutateur de limite
Ignition de surface chaud
Commutateur de pression,
premier stage
Commutateur de pression,
deuxieme stage
Commutateur de pression,
condensation
Moteur soufflerie
D'induct moteur
Soupape de gaz
Humidificateur
Thermostat
Capaciteur
Filtre électrique
XFMR
XFMR