5742640-TIM-A-0419
4
Johnson Controls Ducted Systems
Product Nomenclature
Z D T04 N 07 A 2 A A 1
1 B A 4
Z = Package A/C
Product Category
A = Direct Drive
1
B = Direct Drive/Single Input Low Leak Econo
1
D = Direct Drive/Motorized Damper
1
E = Direct Drive/BAS Ready Low Leak Economizer
1
N = Belt Drive
P = Belt Drive/Single Input Low Leak Econo
R = Belt Drive/Motorized Damper
S = Belt Drive/BAS Ready Low Leak Economizer
T = Belt Drive High Static
U = Belt Drive High Static/Single Input Low Leak Economizer
V = Belt Drive High Static/Motorized Damper
W = Belt Drive High Static/BAS Ready Low Leak Economizer
Product Generation
4 = Fourth Generation
5 = Fifth Generation
T03 = 3.0 Ton
Nominal Cooling Capacity
T04 = 4.0 Ton
T05 = 5.0 Ton
TA6 = 6.0 Ton
Product Identifier
Voltage
1 = 208/230-1-60
2
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
Coated Coils
A = Un-Coated
B = E-Coat Cond & Evap Coils
C = E-Coat Condenser Coil
D = E-Coat Evaporator Coil
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
1 = None
2 = SS Drain Pan
Configuration Options
A = Stand Alone Smart Equipment™
C = BACnet MSTP,Modbus,N2 COM Card
F = FDD
H = Hnywll Excel 10 Ctrl, DFS, APS
N = Novar UCM Ctrl, DFS, APS
P = CPC Control, DFS, APS
M = Verasys Single Zone
N = Verasys Change Over Bypass
Control Options
1 = 2" Throwaway Filters
2 = 2” Pleated Filters (Merv 8)
Additional Options
A=No Options
B= Phase Monitor (PM)
C = Coil Guard (CG)
D = Dirty Filter Switch (DFS)
E = PM & CG
F = PM & DFS
G = CG & DFS
H = PM, CG, & DFS
J = Hinged Filter Door & Toolless Access Panels
K = Phase Monitor, Hinged Filter Door & Toolless Access Panels
L = Coil Guard, Hinged Filter Door & Toolless Access Panels
M = Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels
N = Phase Monitor & Coil Guard, Hinged Filter Door & Toolless
Access Panels
P = Phase Monitor & Dirty Filter Switch, Hinged Filter Door &
Toolless Access Panels
Q = Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless
Access Panels
R = Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter
Door & Toolless Access Panels
D =
Standard Efficiency
00 = Cooling Only. Suitable for Field
Installed Electric Heat
Heat Type and Nominal Heat Capacity
05 = 50 MBH Input (T03) Single Stage Only
07 = 75 MBH Input (T04) Single and Two Stage
07 = 75 MBH Input (T03, T05, TA6) Two Stage Only
11 = 100 MBH Input (T03, T05, TA6) Single Stage Only
12 = 115 MBH Input (T03) Two Stage Only
13 = 125 MBH Input (T04, T05, TA6) Single & Two Stage
05 = 5 KW
07 = 7 KW
10 = 10 KW
15 = 15 KW
20 = 20 KW
30 = 30 KW
Gas Heat Options
Electric Heat Options
Heat Type
C = Cooling Only, No Heat Installed
E = Electric Heat
N = Alum Steel, Single Stage
S = Stainless Steel Single Stage
D = Alum Steel, Two Stage
T = Stainless Steel Two Stage
Filter Options
1. Only available on 208/230 Units
A
A = None
B = Low NOx
Low NOx Option
2. 3 - 5 ton only