background image

Owner’s Manual

 

and Installation 

Instructions

High Resolution

Touch Screen

Code No. LIT-12012451
Issued October 3, 2017

model T9580

Residential

Digital Thermostat

  with 

Humidity  Control   

Содержание T9580

Страница 1: ...Owner s Manual and Installation Instructions High Resolution Touch Screen Code No LIT 12012451 Issued October 3 2017 model T9580 Residential Digital Thermostat with Humidity Control...

Страница 2: ...ion inscription signifie simplement que le produit est conforme aux sp cifications techniques d Industry Canada This color touch screen has the ability to receive updates to its firmware Periodically...

Страница 3: ...oint The coolest temperature that the space should drop to before heating is turned on without regard to deadband Icon The word or symbol that appears on the thermostat display Mode The current operat...

Страница 4: ...ng the Time Date 7 Setting the Time 8 Setting the Date 9 Daylight Savings Setup 9 Connecting to Wi Fi 10 WiFi Set up Create a Skyport Account 12 MAIN MENU BUTTONS SCHEDULE 13 View My Schedule 14 Edit...

Страница 5: ...3 Maintenance 24 PREFERENCES 25 User Interface Themes 26 Custom Wallpaper 26 Heat Cool Indicator 26 Sound Options 26 VACATION AWAY 27 Clear Vacation Schedule 28 Set Vacation Schedule 29 Modes Setpoint...

Страница 6: ...ands 54 Free Cooling 56 Heat Pump Settings 57 Heat Pump Lockout Enabled Disabled 57 Heat Pump Lockout Outdoor Temp 57 Aux Heat Lockout Enabled Disabled 57 Aux Heat Lockout Temp 57 Dual Fuel Settings 5...

Страница 7: ...e ColorDisplay Desktop App 69 Uploading Photos 70 INSTALLATION INSTRUCTIONS 71 Remove Replace the Old Thermostat 71 Wire Connections 72 Determining Your Existing Wiring and Equipment 73 Making 4 Wires...

Страница 8: ...Time Fan Button Home Away Button OutdoorTemperature Cooler Button Warmer Button SD Card Slot Menu Button Mode Buttons If optional accessory is used or connected to Skyport Connectivity Symbol Drop Dow...

Страница 9: ...Connected to local access point w IP address without Skyport enabled Connected to local access point w IP address but not yet connected to Skyport Connected to Skyport Connectivity Symbol Table Dropd...

Страница 10: ...for the following 3 days This page displays sensor information Select Onboard to view room temperature sensors that are built into the thermostat Select Wireless to view all wireless sensors that thi...

Страница 11: ...4 Get To Know Your Thermostat Thermostat Info Equipment Configuration Thermostat Outputs These 3 screens are for informational purposes only Settings may not be changed from these screens...

Страница 12: ...hscreen Only use your finger tip to press the touchscreen buttons Use a soft damp cloth to clean the screen CAUTION DO NOT USE ABRASIVE CLEANERS OR CLEANERSTHAT CONTAIN SOLVENTS DO NOT SPRAY ANYTHING...

Страница 13: ...oints simultaneously To adjust heat and cool setpoints individually choose HEAT mode to adjust the heat setpoint and COOL mode to adjust the cool setpoint then return to AUTO mode HEAT OR COOL MODE Pr...

Страница 14: ...OFF Start Schedule Starts On Day Month Stop Schedule Ends On Day Month 2nd Sun March 1st Sun November NOTE When the thermostat is connected to a Skyport account theTime Date are automatically synchro...

Страница 15: ...rrent Time 12 00 AM hr hr min min Press and to set the current time Press when finished Press then to scroll down Press Use AM PM ON Use AM PM OFF For 12 hour AM PM clock For 24 hour clock Choose Pres...

Страница 16: ...5 14 13 12 11 18 19 20 21 22 23 24 31 30 29 28 27 26 25 1 2 3 4 5 6 7 Press Press Daylight Savings Time OFF Daylight Savings Time ON Start Schedule Starts On Day Month Stop Schedule 2nd Sun March Ends...

Страница 17: ...t the access point you wish to connect to from the list Enter the password for the Wi Fi Access Point and press NEXT Select automatic setup and press NEXT When finished a dialog box will appear confir...

Страница 18: ...tic setup and press NEXT When finished a dialog box will appear confirming the successful connection to the local Wi Fi Access Point Select OK then the Wi Fi status page will appear Upon closing of th...

Страница 19: ...cal Wi Fi Access Point but not yet joined to a Skyport account you may join the thermostat to an account by doing the following Select MENU from the thermostat s home screen Scroll down Select Skyport...

Страница 20: ...13 Main Menu Buttons Schedule Schedule View My Schedule Edit My Schedule...

Страница 21: ...t The start time for each time period is adjustable The stop time for each time period is the start time for the next period Press a day of the week to view its settings This may be repeated for each...

Страница 22: ...nd select aTime Period Morning Day Evening or Night to edit Edit My Schedule Continued Adjust Mode StartTime and Heat and Cool Setpoints to desired settings Save Edit Next TheTime Period may also be E...

Страница 23: ...16 Main Menu Buttons Smart Fan Who To Call For Service View Runtime Graphs Smart Fan OFF Smart Fan Min Runtime Smart Fan Who To Call For Service View Runtime Graphs Start Stop Times Days To Run Fan...

Страница 24: ...day Press to turn fan schedule on or off Set the minimum number of minutes the fan will run from the top of each hour Set runtime to 60 minutes to be on continuously from StartTime to Stop time 5 60 m...

Страница 25: ...raphs Screensaver OFF Screensaver Setup Screensaver Turn On Delay Change Image After Show Clock OFF Screensaver Type Screensaver Home Screen Info OFF View Runtime Graphs Screensaver Preview Slideshow...

Страница 26: ...ore returning to the Home Screen After the preview press anywhere on the screen to return to the sub menu Screensaver Screensaver Setup The Screensaver allows you to create custom slideshows Screensav...

Страница 27: ...Filter Reminder OFF Set Max Filter Runtime Reset Air Filter Alert Reset UV Lamp Alert Alerts Set Edit Reminders Service Information UV Lamp Reminder OFF Max UV Lamp Runtime 300 hrs Set Max Filter Days...

Страница 28: ...rrent service alerts Set service alert runtimes and turn reminders on or off View and reset current service alerts here Alerts will appear on the bottom bar of the Home Screen Press to view and reset...

Страница 29: ...22 Main Menu Buttons Display Screen Cleaning Touch Calibration Active Brightness Night Dimmer Display Maintenance Auto Night Dimmer OFF Set Idle Brightness Set Dimmer Schedule Idle Brightness...

Страница 30: ...splay is active for 3 minutes after last touch it then goes Idle You may dim the brightness of the screen at night The screen can be set to dim automatically at night Dimming the display can prolong t...

Страница 31: ...ean and calibrate the touch screen Screen Cleaning Mode disables the touch feature for 15 seconds so the screen may be cleaned without altering any settings Under normal circumstances the touchscreen...

Страница 32: ...tons Preferences User Interface Themes Custom Wallpaper Heat Cool Indicator OFF Taskbar red white OFF Room Temp red blue OFF Mode Status red blue OFF Preferences Heat Cool Indicator Sound Options Beep...

Страница 33: ...ound will change to an evening scene At 7am it will return to a daytime scene You may choose your own background image by selecting a photo that you have uploaded from an SD memory card Sound Options...

Страница 34: ...n Menu Buttons Vacation Away Clear Vacation Schedule Set Vacation Schedule Start Date Start Time Return Date Return Time Vacation Away Mode Heat Setpoint Cool Setpoint Settings while away OFF Auto Hea...

Страница 35: ...out changing the regular schedule Pressing the HOME button will return the thermostat to normal comfort settings Vacation Away Removes the stored vacation schedule Start Date Tue Sep 07 2010 Start Tim...

Страница 36: ...n Date Tue Sep 21 2010 Return Time 3 00 PM Mode Heat Setpoint Cool Setpoint 85 50 Continued Select the day Vacation Mode will end Then press Select the time Vacation Mode will end Then press Select th...

Страница 37: ...Auto Screenlock Setpoint Limits Security Auto Screenlock OFF Set Passcode Lock After Setpoint Limits OFF Minimum Cool Setpoint Maximum Heat Setpoint Allow fan mode changes NO Allow setpoint changes N...

Страница 38: ...must be set before Auto Screenlock can be turned on Press UNLOCK then enter passcode to access thermostat settings Set the time the screen will automatically lock after the last button press When the...

Страница 39: ...32 Main Menu Buttons Information View Runtime Graphs Information Last 7 Days Cooling Last 7 Days Heating Who To Call For Service Delete Runtime Data...

Страница 40: ...be displayed here Dealer s Logo here View Runtime Graphs Last 7 Days Cooling Last 7 Days Heating Track your system s runtime energy usage Press the information icon to learn more about each graph Pres...

Страница 41: ...Fahrenheit Celsius Heat Cool Stages Compressor Stages Aux Heat Stages English Spanish Espanol French Francais Heat Cool Stages Continued next page Import Settings from SD Card Export Settings to SD C...

Страница 42: ...nd Stage Turnoff Point 3rd Stage Deadband Deadband Setpoint 3rd Stage Deadband 3rd Stage Timer 3rd Stage Turnoff Point 4th Stage Deadband Deadband Setpoint 4th Stage Deadband 4th Stage Timer 4th Stage...

Страница 43: ...p Lockout Enabled Disabled AUX Output Usage AUX Output Polarity Continued next page Sensor Settings AUX Output Settings Control Source Thermostat Sensor Only Wired Sensor Only Average All Wireless Sen...

Страница 44: ...Settings Dealer Information Dealer Name Contact Name Dealer Phone Dealer Email Dealer Website Factory Defaults Restart Thermostat Installation Settings Settings Test Outputs Upgrade Firmware Delete Cu...

Страница 45: ...ons are found in this menu Name appears here General Setup Units F Fahrenheit F Celsius C SD Card Import and export files to and from the thermostat See the ColorDisplay Desktop App instructions for f...

Страница 46: ...e to adjust When used with a heat pump electric strip heat will be disabled while Smart Recovery is active Language en English Spanish Espa ol French Fran ais Menu Button Press for Cooling Press for H...

Страница 47: ...r the comfort settings of the thermostat in order to reduce energy usage on demand This is known as Automated Demand Response or ADR for short You must register to participate in a utility sponsored p...

Страница 48: ...e thermostat is configured to respond to the energy provider s signals It also sets operational parameters for the thermostat The left column of the ADR configuration page allows or prevents access by...

Страница 49: ...tpoints for ADR events are adjusted here The Static Settings are applied when the utility sends a signal to allow the occupant to enforce their own discrete temperature settings during an ADR event Th...

Страница 50: ...43 Selecting the Overview tab of the ADR page will cause a summary of ADR events to be displayed Main Menu Buttons Settings...

Страница 51: ...at the Skyport Cloud Services account From the thermostat Home Screen press the Menu button then select Settings From the above screen the Automated Demand Response button is pressed By selecting ADR...

Страница 52: ...action is taken when the price rises above the set threshold In the above example if the price threshold is exceeded the thermostat will invoke the Offset Setpoints configured for an ADR event until t...

Страница 53: ...46 Main Menu Buttons Settings The user may limit the maximum Cooling Setpoint...

Страница 54: ...47 Main Menu Buttons Settings The user may limit the minimum Heating Setpoint...

Страница 55: ...48 Main Menu Buttons Settings 2 The user may adjust the ADR Cooling static Setpoint...

Страница 56: ...49 2 Main Menu Buttons Settings The user may adjust the ADR Heating static Setpoint...

Страница 57: ...50 The user may adjust the ADR Cool offset During an ADR event the cooling setpoint will be adjusted by the amount of degrees configured in this step Main Menu Buttons Settings 2...

Страница 58: ...51 2 Main Menu Buttons Settings The user may adjust the ADR Heat offset During an ADR event the heating setpoint will be adjusted by the amount of degrees configured in this step...

Страница 59: ...ending and hasn t started yet there will be a yellow leaf on the top bar This will be accompanied by associated text as shown below During an ADR event there will be a green leaf on the top bar This w...

Страница 60: ...ssed during an active ADR event then the user is presented with this opt out screen If a pricing triggered ADR event is enabled there will be a green leaf on the top bar along with the actual cost of...

Страница 61: ...ressor Min OFF Time 5m None 3 minutes or 5 minutes At 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes The Cycles Per Hour limit may be overridden and reset by pr...

Страница 62: ...set to 2 degrees the room temperature will need to drop to 66 degrees before the heat turns on 3rd Stage Deadband 4th Stage Deadband 1st Stage Deadband 2 1 6 deg F 2nd Stage Deadband 2nd Stage Deadba...

Страница 63: ...ee Cooling outdoor air damper is closed Free Cooling Mechanical Cooling NO Mechanical Cooling YES If you don t have a compressor set Mechanical Cooling to NO Y1 will then be used to control the Free C...

Страница 64: ...the temperature for changeover to fossil fuel 0 60 deg F This feature is for heat pump applications only This will only appear if the GAS EL or HP dip switch is set for HP and the GAS or ELEC dip swit...

Страница 65: ...58 Installation Settings AUX Output Settings Main Menu Buttons Settings...

Страница 66: ...tat the user may choose which sensor source is used to measure room temperature Wired Sensor Use remote The wired sensor may be used as follows Use as an Outdoor sensor Use as a Remote Sensor Use as a...

Страница 67: ...calibrated 7 to 7 degrees F Thermostat Wired Sensor The installer or service technician can use this feature to test the functions without any time delays of the thermostat Test Outputs With a 1st sta...

Страница 68: ...Card reader and contain the valid firmware If an error message appears confirm with the ColorDisplay Desktop APP that firmware is up to date or simply try reinserting the SD card Dealer s Logo here De...

Страница 69: ...62 Main Menu Buttons Wi Fi Wi Fi Setup Choose Network Password Entry Local API OFF API Protocol Wi Fi Status Wi Fi Enabled Local API Option HTTP HTTPS...

Страница 70: ...to be turned off or on Wi Fi Setup Choose your network from the list and enter the network password If your network does not appear in the list hit the refresh button Network Name 1 Network Name 2 Net...

Страница 71: ...referred then select API Protocol This is the default with the local API OFF Upon pressing API Protocol the following screen will appear Then select HTTPS and press BACK Local API OFF Local API OFF AP...

Страница 72: ...asic Auth User API Protocol http API Protocol http API Protocol https Basic Auth Password Main Menu Buttons Wi Fi Q W E R T Y U I O 64 remaining A S D F G H J K L Shift BACK DONE Basic Auth User 123 S...

Страница 73: ...below and press DONE to save Q W E R T Y U I O 64 remaining A S D F G H J K L Shift BACK DONE Basic Auth Password 123 SPACE Z X C V B N M Del P X Basic Auth Password The last step is to turn the Local...

Страница 74: ...ort Account Skyport Skyport Services ON Weather Updates ON Pressing this button will let you know if you are paired with a Skyport account If not then you may follow prompt and instructions to create...

Страница 75: ...cy Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat The 1st stage of heating and all stages of cooling will be unavailable To exit Emerge...

Страница 76: ...orDisplay Desktop App software it automatically connects to the Johnson Controls ColorDisplay website in the background and updates the software and firmware the operating system for touch screen at n...

Страница 77: ...der on your computer Save to SD SD Card Slot At the thermostat Press then Settings SD Card Insert the SD card into the SD Card Slot Next press Press Then press Select the items to import into your the...

Страница 78: ...power to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Remove the cover of the old thermostat If it...

Страница 79: ...agrams that follow Wire from the Install on the old thermostat Function new thermostat terminal marked connector marked G or F Fan G Y1 Y Cooling Y1 W1 W Heating W1 0 B Rh R M Vr A Power R C Common C...

Страница 80: ...f there are only 4 wires present that are connected to the existing thermostat there are at least 2 options available to connect the JCI thermostat 1 Use the 4 wires as instructed in the Making 4 Wire...

Страница 81: ...m the HVAC equipment to the thermostat so that there are at least 5 wires available E If you have a heat pump with aux heat the JCI model will require 6 wires R 24Vac C 24Vac W1 O B Reversing Valve Y...

Страница 82: ...erminals that the wires are attached to 4 Remove the G wire from the terminal marked G 5 Place the G wire on terminal C 6 Place one end of the 3 long jumper on terminal G 7 Place the other end of the...

Страница 83: ...locate the terminals that the wires are attached to 4 Remove the G wire from the terminal marked G 5 Place the G wire on terminal C 6 Place one end of the 3 long jumper on terminal G 7 Place the other...

Страница 84: ...equires both R 24 VAC Return and C 24 VAC Common be connected to the backplate terminals To remove the thermostat backplate Using the Finger Pull Areas pull the front housing away from the backplate L...

Страница 85: ...cooling If B is chosen the W1 O B terminal will energize in heating 1 When GAS EL or HP is set for GAS EL This switch GAS or ELEC controls how the thermostat will control the Fan G terminal in heating...

Страница 86: ...Wire 1 Stage Cooling 1 Stage Heat 24VAC Power 24VAC Common 1st Stage Heat 1st Stage Cool Fan Residential Commercial 2 Stage Cooling with 3 stage Gas Heat 8 Wire 2 Stage Cooling 3 Stage Heat 24VAC Powe...

Страница 87: ...r Heat Y2 2nd Stage Compressor Cool or Heat G Fan Residential Commercial Heat Pump with O ReversingValve 6 Wire 1 Stage Cooling 2 Stage Heat R 24VAC Power C 24VAC Common W1 O B Reversing Valve Y1 1st...

Страница 88: ...ohm sensor at 77F 25C NegativeTemperature Coefficient Residential Commercial Heat Pump with O ReversingValve and Fossil Fuel furnace 7 Wire 2 Stage Cooling 3 Stage Heat R 24VAC Power C 24VAC Common W...

Страница 89: ...imit See Setpoint Limits page 29 SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Raise the heating setpoint or raise the heating set point limit See Se...

Страница 90: ...Color Display Desktop App 69 Compressor Lockout 54 Cool 1st stage deadband see Deadband 2nd stage deadband see Deadband Minutes of runtime 33 54 Custom Wallpaper 26 Cycles Per Hour 54 Daylight Saving...

Страница 91: ...inutes of runtime 33 2nd stage deadband see Deadband electric strip heat see Aux Heat minutes of runtime 33 3rd stage deadband see Deadband 4th stage deadband see Deadband timer 55 turnoff point 55 el...

Страница 92: ...stat settings see Factory Defaults runtime fan filter 21 UV light 21 Reversing Valve 77 80 Runtime resetting see Reset service filter 21 UV light 21 viewing 21 33 Schedule turn on off 14 15 view 14 15...

Страница 93: ...age to 3rd stage 55 3rd stage to 4th stage 55 Time schedule see Schedule Touch Calibration 24 Upgrade Firmware 61 User InterfaceThemes 26 UV Light resetting 21 runtime see Runtime setting see Runtime...

Страница 94: ...N WHATSOEVER ALL WORK UNDERTHETERMS OFTHIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME ASTHEIR WARRANTY PERIOD ONLYTHE REMAININGT...

Страница 95: ...Adjustment Range Accuracy Wire Size Deadband Operating Storage Ambient Conditions Compliance Dimensions Shipping Weight This equipment has been tested and found to comply with the limits for a Class...

Страница 96: ...Printed on recycled paper LIT 12012451 Rev 1 10 17...

Отзывы: