background image

ComPAC
Chiller unit with screw compressor

Operating manual

en

Содержание SABROE ComPAC

Страница 1: ...ComPAC Chiller unit with screw compressor Operating manual en...

Страница 2: ......

Страница 3: ...III controller You can find the compressor number and the equipment configured on your unit below Compressor type Designation Compressor no Refrigerant R717 Oil type PAO68 Other _____________ Level co...

Страница 4: ...External surface m2 Design pressure bar Condenser Float housing Evaporator Liquid separator Oil separator Oil cooler Receiver Economiser Desuperheater Subcooler Other Pressure loss if any from safety...

Страница 5: ...17 2 2 5 Signs 18 2 3 Safety precautions 19 2 3 1 General precautions 19 2 3 2 During operation 19 2 3 3 Cooling water systems 20 2 3 4 Cooling media 20 2 3 5 Safety during maintenance and service 20...

Страница 6: ...VSD 37 4 4 Secondary system 38 4 4 1 General information 38 4 4 2 Cleaning in place 38 4 4 3 Temperature and flow control 38 4 4 4 Water and brine treatment 38 4 4 5 R717 detector 38 5 Operating instr...

Страница 7: ...intenance instructions 49 6 1 Maintenance of the chiller unit 49 6 2 Selecting lubricating oil for ComPAC units 49 6 3 R717 charge 50 7 Final disposal 51 7 1 Safety precautions 51 7 2 Waste disposal 5...

Страница 8: ...t that the operating personnel familiarise themselves with the contents of this manual in order to ensure a proper and efficient operation Johnson Controls Den mark is not liable for damage occurring...

Страница 9: ...ction has been updated Updated version of declaration of conformity for unit 2018 01 Version 2 Name plates with EurAsian Conformity mark EAC have been added Requirements for competent persons section...

Страница 10: ...injury Note Indicates an operating procedure practice etc or portion thereof which is essential to highlight 1 1 3 Requirements for competent persons Personnel working on the unit must be competent in...

Страница 11: ...must only take place if the chiller is fitted with approved explosion proof equipment The compressor must only be used as a refrigeration compressor and within the operating limits specified in the ma...

Страница 12: ...pment from Johnson Controls Denmark can be identified by one or several name plates positioned as illustrated in the following drawing Fig 1 Identification of equipment Pos no Name plate for 1 Compres...

Страница 13: ...jbjerg Denmark www sabroe com Fig 2 Name plate for standard unit Scope Design code Approval No Refrigerant Supply voltage Test pressure Allowable pressure Category Pressure system Refrigerant charge...

Страница 14: ...ssure side of the unit piping system is referred to as the LP side The high pressure side of the unit piping system is referred to as the HP side Category For EC PED approval The maximum category of t...

Страница 15: ...pt volume Pressure system Allowable pressure Test pressure LP side HP side No Type Year Speed bar g bar g m3 h Max rpm Fig 6 Name plate for ATEX compressor Fig 7 Name plate for compressor with EurAsia...

Страница 16: ...e compressor at nominal speed Pressure system The low pressure side of the compressor is referred to as the LP side The high pressure side of the compressor is referred to as the HP side Allowable pre...

Страница 17: ...1 2 3 or 4 according to the PED directive Side For heat exchangers only Refers to the columns Shell side and Tube side Fluid Designation of the primary refrigerant s and the secondary re frigerant s F...

Страница 18: ...re usu ally delivered without refrigerant and oil To protect the compressors against internal corrosion they are delivered evacuated of all atmospheric air and charged with dry Nitrogen N2 to an overp...

Страница 19: ...and or lubricating oil Use proper electrical safety protection Note These instructions only provide general information The owner of the refrigeration plant is responsible for ensuring that all codes...

Страница 20: ...ad chapter 2 Safety in this manual before opening the compressor and other parts of the refrigeration plant If the switch is not locked all start buttons must be tagged with DO NOT START tags and an e...

Страница 21: ...t the used oil in containers marked waste oil and send them to an approved hazard ous waste disposal site It is not recommended to reuse oil 2 3 8 Refrigerants Be very careful when dealing with refrig...

Страница 22: ...Warming Potential according to the F gas regulation The so called HFOs and nat ural refrigerants do not fall under the scope of the regulation Refrigerant GWP Global Warming Potential R134a 1300 R407...

Страница 23: ...to ensure that the repair has been effective Recovery of refrigerant Operators are responsible for putting in place arrangements for the proper recovery of fluorinated greenhouse gases by competent pe...

Страница 24: ...ns with ammonia When applying first aid the persons assisting must be duly protected to avoid further injuries First aid measures Inhalation Immediately move affected personnel into fresh air and loos...

Страница 25: ...uman nervous system When halogenated gasses come into contact with open flame or hot surfaces over approx 300 C they will decompose to produce poisonous chemicals These have a very pungent odour and w...

Страница 26: ...p In case of an accident push the emergency stop button on the Unisab III controller Fig 11 Unisab III built into the electrical panel Fig 12 Unisab III as a separate device For resetting and further...

Страница 27: ...frigerant Once the unit is charged with R717 connected to electricity and pipe connections to water brine are established it is ready for operation The unit is provided with adjustable anti vibration...

Страница 28: ...tlet evaporator 17 Oil filter 5 Inlet evaporator 18 Oil cooler 6 Condenser 19 High level alarm 7 Outlet condenser 20 Heat recovery inlet optional 8 Inlet condenser 21 Heat recovery outlet optional 9 E...

Страница 29: ...heat exchanger where plates are welded together into cas settes R717 evaporates between the two welded plates which make up the cassettes and water brine is cooled in the channels inside the cassettes...

Страница 30: ...e 4 Connection for safety valves 5 Connection for manometer 6 Connection discharge pressure to oil recovery system 7 Drain including stop valve and quick closing drain valve 8 Sight glasses for liquid...

Страница 31: ...under the condens er in order to obtain a compact design and a very low refrigerant charge The float valve is fixed with a screw pos 2 in Fig 14 The float valve is equipped with a turning mechanism w...

Страница 32: ...t valve cover at the bottom of the condenser Fig 14 pos 3 Note The valve at the bottom of the cover Fig 14 pos 4 is used for liquid draining R717 During air purging the air purge valve should be conne...

Страница 33: ...717 The float has a built in reed switch which activates the solenoid valve pos 8 in Fig 15 in the oil return line to the compressor and the solenoid valve pos 7 in Fig 15 on the hot gas line The oil...

Страница 34: ...nsure proper functioning a timer delays the off signal from the float switch for a few seconds Note As shown in Fig 16 the float ball must be positioned with NO facing upwards For further information...

Страница 35: ...space for operation and maintenance in accordance with GA drawing 3 Place the unit on a foundation suitable for the actual load and vibrations With or without vibration dampers according to the vibrat...

Страница 36: ...es should not be completely covered by liquid Check that the suction superheat is between 0 5 and 3 K If higher carefully charge more R717 18 Check the R717 liquid level again Note The liquid level mu...

Страница 37: ...ion dampers are often required In such cases it is recommended to replace the machine feet with specially designed vibration dampers Contact a vibration expert or a Johnson Controls Denmark representa...

Страница 38: ...utlet pipe minimum 1 metre away from the evaporator 4 4 4 Water and brine treatment Brine and water for industrial refrigeration plants often contain impurities that can create a coat ing fouling on t...

Страница 39: ...mation risk of damaging secondary piping and components material corrosion secondary refrigerant e g glycol in case of leakage Leak detectors should be selected installed and maintained in cooperation...

Страница 40: ...installation of safety equipment is completed according to the installation information Make sure that all necessary documents are available including operating manuals machine card logbooks etc and o...

Страница 41: ...fore start up Fig 18 Unisab III front 5 3 2 Normal start up procedure 1 Confirm that the system conditions permit the chiller to start 2 Press the start button on Unisab III 3 Allow the compressor to...

Страница 42: ...ne outlet closed 418 Safety relief valve Closed Fixed set point 419 Safety relief valve Closed Fixed set point 420 Double stop valve One outlet open one outlet closed 421 Safety relief valve Closed Fi...

Страница 43: ...Operating manual ComPAC 011769 en 2020 03 43 56 Operating instructions Fig 19 P I diagram for ComPAC...

Страница 44: ...ked 2 Check that oil pressure is obtained and that the evaporating and condensing pressures are within the permissible ranges 3 Check the other operating data 4 Check for abnormal noise and vibrations...

Страница 45: ...components electric motors valves etc Check unit installation and vibration damper adjustment Carry out functional testing of safety equipment Read the opening pressures on all safety valves and chec...

Страница 46: ...and compressor weekly monthly according to below 4 If the compressor is water cooled drain of the water To reduce the risk of bearing damage it is recommended to rotate to a new position the motor an...

Страница 47: ...ox 0 5 to 3 K A 1 K higher evaporating temperature results in a 4 higher cooling performance Missing oil During the first 50 hours of operation the compressor will lose oil A few litres of oil will ac...

Страница 48: ...anges in compressor capacity Adjust settings for load unload compressor capacity in Unisab III Too much compressor cooling Reduce water flow or temperature to compressor cooling See compressor manual...

Страница 49: ...ssible ranges Compare them with previous values to detect trends Check the oil level Check the refrigerant charge Observe for leaks of refrigerant smell of ammonia oil glycol or water Check mechanical...

Страница 50: ...ecific chiller At normal operation the suction superheat should be between 0 5 3 K In the evaporator droplets should come out of the top of the plates The plates must not be com pletely covered by liq...

Страница 51: ...when using cutting tools such as angle grinders or flame cutters during the dis mantling process as pipes and the like contain oil residue and refrigerant which may be toxic and or flammable 7 2 Wast...

Страница 52: ...rts list for HP float valve Fig 21 HP float valve Pos Pcs Part no Description 1 1 1331 672 O ring 2 1 1331 126 O ring 3 040 1 1364 405 HP Float valve HFI 040 3 050 1 1364 406 HP Float valve HFI 050 3...

Страница 53: ...1 3247 128 Complete pot 1 1 3445 508 Float switch 2 1 1331 433 Seal ring 3 1 3413 038 Piston 4 1 3411 009 Oil reservoir 5 1 2144 049 Spring 6 1 3411 039 Cover 7 1 1331 571 O ring 8 4 1425 018 Screw M...

Страница 54: ...eclaration however not filled in with the specific data for your unit The translated version is also included in the operating manual that is available for download with the rest of the order specific...

Страница 55: ...n 11 Competent persons requirements 10 Compressor 29 Compressor name plates 15 Condenser 29 Control system 29 Cooling media 20 Cooling water systems 20 CVUA 1201 oil recovery pot 53 D Declaration of c...

Страница 56: ...Receiver 30 Refrigerants 21 Restarting 44 S Safety during maintenance and service 20 Safety signs 18 Selecting lubricating oil 49 Shutting down 46 Sound and noise data 36 Spare parts list 52 53 Start...

Страница 57: ......

Страница 58: ...Johnson Controls Denmark ApS SABROE Factory Christian X s Vej 201 8270 H jbjerg Denmark Phone 45 87 36 70 00 www sabroe com Version 4...

Страница 59: ...alculations are made by spreadsheet tool version 1 5 3 date 2013 09 01 Diagram lines drawn as straight lines between legal condition points and product points See data and calculation on page 2 Degrad...

Страница 60: ...or Inlet outlet 12 7 Evaporator Inlet outlet 12 7 Evaporator Inlet outlet 12 7 2 8 12 7 2 8 12 7 Evaporator Inlet outlet Reciprocating Screw Evaporator Inlet outlet 12 7 Evaporator Inlet outlet Eta s...

Отзывы: