Johnson Controls MC-303 PG+ Скачать руководство пользователя страница 6

Local diagnostics test

About this task:  

After power-up or closing the cover, the device automatically enters Test Mode for 15 minutes. To

manually enter the devices into Test Mode refer to the Control Panel Installer Guide.

1. Before you start the test, remove the device cover from the base. See Figure 4.

2. Close the cover to return the tamper switch to its normal position.

3. Momentarily open the door or window and verify the red LED blinks, indicating detection.

After 2 seconds one of the LEDs blinks three times.

The following table displays the received signal strength indication.

Table 3: Signal strength indication

LED response

Reception

Green LED blinks

Strong

Yellow LED blinks

Good

Red LED blinks

Poor

No blinks

No communication

Important: 

 Reliable reception must be assured. Therefore, poor signal strength is not

acceptable. If you receive a poor signal from the device, relocate it and re-test until a

strong signal strength is received .

Note: 

It is recommended to have a strong signal strength and you must verify the

signal strength using the control panel's diagnostic test. For detailed Diagnostics Test

instructions, refer to the control panel installer guide.

Specifications

Table 4: Specifications

Frequency Band

912 to 919 MHz

Modulation

GFSK

Communication Protocol

PowerG

Battery Type

3 V Lithium CR2450 Panasonic or GP battery only

Battery Life

6 years with typical use at room temperature 25°C (77°F)

Low Battery Threshold

2 V at room temperature 25°C (77°F)

Nominal Operating Voltage

3 V

Operating Temperature

-10°C (14°F ) to 55°C (131°F)

Storage Temperature

-20°C (-4°F) to 70°C (158°F)

Relative Humidity

Up to 95% non-condensing

Dimensions (LxWxD)

68 mm x 31 mm x 12 mm (2.7 in. x 1.1 in. x 0.4 in.)

Weight (including battery)

20 g (0.71 oz)

Color

White

MC-303 PG+ Vanishing Door/Window Magnetic Contact Installation Guide

6

D-308437 MC-303 PG+ Rev. 0

Содержание MC-303 PG+

Страница 1: ...e entire alarm system weekly to ensure optimal performance Note To comply with FCC RF exposure compliance requirements locate the device at a distance of at least 20 cm from all persons during normal...

Страница 2: ...identified by the system only after the device has been reset The MC 303 PG is enrolled with device ID 103 XXXX In fall back mode it enrolls as MC 303 PG2 with device ID 109 XXXX 6 Select the desired...

Страница 3: ...insert and turn a 4mm flat screwdriver into the four corners of the device Figure 4 Device cover removal 2 Screw the device base on to the door or window frame See figure 5 A Note Make sure to fasten...

Страница 4: ...ries away from children If the battery compartment does not close securely stop using the product and keep it away from children Seek immediate medical attention if you think batteries might have been...

Страница 5: ...e directional magnet distances that trigger open or close events Figure 7 Range coverage directions Table 2 Directional magnet distances for event triggers Non metallic surface Supports Metallic surfa...

Страница 6: ...ceptable If you receive a poor signal from the device relocate it and re test until a strong signal strength is received Note It is recommended to have a strong signal strength and you must verify the...

Страница 7: ...ult the dealer or an experienced radio TV technician for help WARNING Changes or modifications to this equipment not expressly approved by the party responsible for compliance Visonic Ltd could void t...

Страница 8: ...other than the Seller are not covered by this Warranty There is absolutely no warranty on software and all software products are sold as a user license under the terms of the software license agreemen...

Страница 9: ...to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limita...

Страница 10: ...site www visonic com D 308437 Rev 0 01 22 2022 Johnson Controls All rights reserved JOHNSON CONTROLS TYCO and VISONIC are trademarks and or registered trademarks Unauthorized use is strictly prohibite...

Отзывы: