FORM 145.05-EG2 (618)
6
JOHNSON CONTROLS
Features and Benefits (Cont’d)
Easier Maintenance
• Large, intuitive operator interface makes for quick set up and easier diagnostics. It is
on the external panel for easy viewing.
• Operator interface for optional VFD on the external panel.
• Easy access to important components through hinged doors for easy maintenance.
• Easily accessible components out of the air stream allow adjustment of components,
including expansion valves, while unit is operating.
•
Easy filter access for inspection, removal, and replacement.
• Internally trapped condensate drain cleanout with easy access.
• Available BACnet
®
communications with Building Automation System (BAS) al-
lows for easier control of larger installations.
• Emergency stop input.
Indoor Air Quality
• Condensate drain pan sloped in all directions to the drain point.
• Stainless steel drain pan standard
•
High efficiency filters option with pre-filters.
• Evaporator and waterside economizer coils surface may be cleaned from air entering
side as well as air leaving side.
• Easy access to internally trapped condensate drain cleanout.
•
Matt faced fiberglass insulation.
Quieter Acoustic Performance
•
Plenum fan with backward inclined airfoil blades provides required airflow at a low
-
er sound power level compared to the most competitive units.
• Unique placement of internal components minimizes amount of acoustic energy
leaving the unit.
• Supply fan and motor assembly mounted on a frame and isolated with springs.
•
Optional discharge plenum configurations allow horizontal supply air discharge,
minimizing the outlet sound and pressure losses.
•
Optional inlet plenum configuration minimizes sound escaping the unit inlet.
•
Multiple scroll compressors, due to their smoother flow and stepped operation, mini
-
mize the sound associated with the refrigerant system.
• The compressors are located out side air stream, including all the refrigerant piping
and condenser water piping.
Содержание L-Series
Страница 1: ...FORM 145 05 EG2 618 ENGINEERING GUIDE Water Cooled Self Contained Units L Series Vertical ...
Страница 4: ...FORM 145 05 EG2 618 4 JOHNSON CONTROLS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 14: ...FORM 145 05 EG2 618 14 JOHNSON CONTROLS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 33: ...FORM 145 05 EG2 618 JOHNSON CONTROLS 33 Dimensional Data OVERVIEW OF COMBINED UNIT LSWU025 040 MODELS ...
Страница 34: ...FORM 145 05 EG2 618 34 JOHNSON CONTROLS Dimensional Data Cont d OVERVIEW OF SPLIT SHIPMENT LSWU025 040 MODELS ...
Страница 35: ...FORM 145 05 EG2 618 JOHNSON CONTROLS 35 OVERVIEW OF SERVICE CLEARANCES LSWU025 040 MODELS ...
Страница 50: ...FORM 145 05 EG2 618 50 JOHNSON CONTROLS OVERVIEW OF SPLIT SHIPMENTS LSWU070 105 MODELS Dimensional Data Cont d ...