QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
51
178
SOUND
FIND IT
SOUND
Swipe down
for access
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
Setting
Default
Description
Trouble Beeps
Trouble Beeps
Disabled
Toggles all sensor and panel trouble beeps on or off. By default all
trouble beeps are disabled
Sensor Low Battery
Disabled
Panel sounds when a sensor battery is low. Chime type and
frequency are set below. By default these sounds are disabled
Sensor Tamper Beeps
Disabled
Panel sounds when a sensor is tampered. Chime type and frequency
are set below. By default these sounds are disabled
Panel Tamper Beeps
Disabled
Panel sounds when tampered or opened. Chime type and frequency
are set below. By default these sounds are disabled
Edit Trouble Beep
Chimes
n/a
Select the chime type for Sensor Low Battery, Sensor Tamper, and
Panel Tamper
Trouble Beeps
Timeout
30
Determines the amount of time between each trouble beep. Length
can be set between 3-60 mins. (default is 30 mins)
Fire and Life Safety
Device Trouble Beeps
Disabled
Panel will sound a trouble alert if a fire safety device is tampered,
failed or has a low battery (disabled by default)
PROGRAMMING
Содержание IQ Panel 4
Страница 8: ...INSTALLING THE PANEL ...
Страница 15: ...USER INTERFACE ...
Страница 19: ...PROGRAMMING ...
Страница 56: ...SECURITY SENSORS ...
Страница 89: ...WI FI DEVICES ...
Страница 96: ...Z WAVE DEVICES ...
Страница 107: ...BLUETOOTH DEVICES ...
Страница 114: ...SYSTEM TESTS ...
Страница 137: ...CUSTOMIZATION ...
Страница 146: ...MAINTENANCE ...
Страница 153: ...TROUBLESHOOTING ...
Страница 162: ...LEGAL ...
Страница 173: ...SPECIFICATIONS ...