Refrigerant Precautions
To reduce the risk of serious injury or death, the following refrigerant
precautions must be followed.
Ɣ
$VRULJLQDOO\PDQXIDFWXUHGWKLVXQLWFRQWDLQVUHIULJHUDQWLQVWDOOHGE\-RKQVRQ&RQWUROV-RKQVRQ
&RQWUROVXVHVRQO\UHIULJHUDQWVWKDWKDYHEHHQDSSURYHGIRUXVHLQWKHXQLW¶VLQWHQGHGKRPHFRXQWU\
RUPDUNHW-RKQVRQ&RQWUROVGLVWULEXWRUVVLPLODUO\DUHRQO\DXWKRUL]HGWRSURYLGHUHIULJHUDQWVWKDW
have been approved for use in the countries or markets they serve. The refrigerant used in this unit
LVLGHQWL¿HGRQWKHXQLW¶VIDFHSODWHDQGRULQWKHDVVRFLDWHGPDQXDOV$Q\DGGLWLRQVRIUHIULJHUDQWLQWR
WKLVXQLWPXVWFRPSO\ZLWKWKHFRXQWU\¶VUHTXLUHPHQWVZLWKUHJDUGWRUHIULJHUDQWXVHDQGVKRXOGEH
REWDLQHGIURP-RKQVRQ&RQWUROVGLVWULEXWRUV8VHRIDQ\QRQDSSURYHGUHIULJHUDQWVXEVWLWXWHVZLOOYRLG
the warranty and will increase the potential risk of injury or death.
Ɣ
If installed in a small room, take measures to prevent the refrigerant from exceeding the maximum
allowable concentration in the event that refrigerant gases should escape. Refrigerant gases can
cause asphyxiation (0.026 lbs/ft
3
(0.42 kg/m
3
) based on ISO 5149 for R410A). Consult with your
distributor for countermeasures (ventilation system and so on). If refrigerant gas has leaked during the
installation work, ventilate the room immediately.
Ɣ
Check the design pressure for this product is 601 psi (4.15MPa). The pressure of the refrigerant
R410A is 1.4 times higher than that of the refrigerant R22. Therefore, the refrigerant piping for
5$VKDOOEHWKLFNHUWKDQWKDWIRU50DNHVXUHWRXVHWKHVSHFL¿HGUHIULJHUDQWSLSLQJ,IQRWWKH
refrigerant piping may rapture due to an excessive refrigerant pressure. Besides, pay attention to
the piping thickness when using copper refrigerant piping. The thickness of copper refrigerant piping
differs depending on its material.
Ɣ
The refrigerant R410A is adopted. The refrigerant oil tends to be affected by foreign matters such
DVPRLVWXUHR[LGH¿OPRUIDW3HUIRUPWKHLQVWDOODWLRQZRUNZLWKFDUHWRSUHYHQWPRLVWXUHGXVWRU
different refrigerant from entering the refrigerant cycle. Foreign matter can be introduced into the cycle
from such parts as expansion valve and the operation may be unavailable.
Ɣ
To avoid the possibility of different refrigerant or refrigerant oil being introduced into the cycle, the
sizes of the charging connections have been changed from R407C type and R22 type. It is necessary
to prepare the appropriate tools before performing installation work.
Ɣ
Use refrigerant pipes and joints which are approved for use with R410A.
Ɣ
A compressor/unit comprises a pressurized system. Never loosen threaded joints while the system is
under pressure and never open pressurized system parts.
Ɣ
Before installation is complete, make sure that the refrigerant leak test has been performed. If
UHIULJHUDQWJDVHVHVFDSHLQWRWKHDLUWXUQ2))WKHPDLQVZLWFKH[WLQJXLVKDQ\RSHQÀDPHVDQG
contact your service contractor. Refrigerant (Fluorocarbon) for this unit is odorless. If the refrigerant
VKRXOGOHDNDQGFRPHLQWRFRQWDFWZLWKRSHQÀDPHVWR[LFJDVFRXOGEHJHQHUDWHG$OVREHFDXVHWKH
ÀXRURFDUERQVDUHKHDYLHUWKDQDLUWKH\VHWWOHWRWKHÀRRUZKLFKFRXOGFDXVHDVSK\[LDWLRQ
Ɣ
When installing the unit, and connecting refrigerant piping, keep all piping runs as short as
possible, and make sure to securely connect the refrigerant piping before the compressor starts
operating. If the refrigerant piping is not connected and the compressor activates with the stop
valve opened, the refrigerant cycle will become subjected to extremely high pressure, which can
FDXVHDQH[SORVLRQRU¿UH
Ɣ
7LJKWHQWKHÀDUHQXWZLWKDWRUTXHZUHQFKLQWKHVSHFL¿HGPDQQHU'RQRWDSSO\H[FHVVLYHIRUFHWRWKH
ÀDUHQXWZKHQWLJKWHQLQJ,I\RXGRWKHÀDUHQXWFDQFUDFNDQGUHIULJHUDQWOHDNDJHPD\RFFXU
Ɣ
When maintaining, relocating, and disposing of the unit, dismantle the refrigerant piping after the
compressor stops.
Ɣ
When pipes are removed out from under the piping cover, after the insulation work is completed,
FRYHUWKHJDSEHWZHHQWKHSLSLQJFRYHUDQGSLSHVE\DSDFNLQJ¿HOGVXSSOLHG,IWKHJDSLVQRW
covered, the unit may be damaged if snow, rain water or small animals enter the unit.
Ɣ
Do not apply an excessive force to the spindle valve at the end of opening. Otherwise, the spindle
YDOYHÀLHVRXWGXHWRUHIULJHUDQWSUHVVXUH$WWKHWHVWUXQIXOO\RSHQWKHJDVDQGOLTXLGYDOYHV
otherwise, these devices will be damaged. (It is closed before shipment.)
Ɣ
,IWKHDUUDQJHPHQWIRURXWGRRUXQLWVLVLQFRUUHFWLWPD\FDXVHÀRZEDFNRIWKHUHIULJHUDQWDQGUHVXOWLQ
failure of the outdoor unit.
Ɣ
The refrigerant system may be damaged if the slope of the piping connection kit e15
o
.
Содержание HIDH018B21S
Страница 2: ......
Страница 40: ......
Страница 71: ...OUTDOOR UNITS TC 15001 rev 3 2 31 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 72: ...OUTDOOR UNITS 2 32 TC 15001 rev 3 0RGHO 9 3 6 LQFK PP ...
Страница 73: ...OUTDOOR UNITS TC 15001 rev 3 2 33 0RGHO 9 3 6 LQFK PP ...
Страница 74: ...OUTDOOR UNITS 2 34 TC 15001 rev 3 0RGHO 9 3 6 LQFK PP ...
Страница 75: ...OUTDOOR UNITS TC 15001 rev 3 2 35 0RGHO 9 3 6 LQFK PP ...
Страница 76: ...OUTDOOR UNITS 2 36 TC 15001 rev 3 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 77: ...OUTDOOR UNITS TC 15001 rev 3 2 37 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 78: ...OUTDOOR UNITS 2 38 TC 15001 rev 3 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 79: ...OUTDOOR UNITS TC 15001 rev 3 2 39 0RGHO 9 3 0 Ɣ HVV 0RGXOH 7 SH ...
Страница 80: ...OUTDOOR UNITS 2 40 TC 15001 rev 3 0RGHO 9 3 0 DQG 9 3 0 ...
Страница 81: ...OUTDOOR UNITS TC 15001 rev 3 2 41 0RGHO 9 5 6 LQFK PP HDW 5HFRYHU 6 VWHP Ɣ 6WDQGDUG 7 SH ...
Страница 82: ...OUTDOOR UNITS 2 42 TC 15001 rev 3 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 83: ...OUTDOOR UNITS TC 15001 rev 3 2 43 0RGHO 9 5 6 LQFK PP ...
Страница 84: ...OUTDOOR UNITS 2 44 TC 15001 rev 3 0RGHO 9 5 6 LQFK PP ...
Страница 85: ...OUTDOOR UNITS TC 15001 rev 3 2 45 0RGHO 9 5 6 LQFK PP ...
Страница 86: ...OUTDOOR UNITS 2 46 TC 15001 rev 3 0RGHO 9 5 6 LQFK PP ...
Страница 87: ...OUTDOOR UNITS TC 15001 rev 3 2 47 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 88: ...OUTDOOR UNITS 2 48 TC 15001 rev 3 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 89: ...OUTDOOR UNITS TC 15001 rev 3 2 49 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 90: ...OUTDOOR UNITS 2 50 TC 15001 rev 3 0RGHO 9 5 0 Ɣ HVV 0RGXOH 7 SH ...
Страница 91: ...OUTDOOR UNITS TC 15001 rev 3 2 51 0RGHO 9 5 0 DQG 9 5 0 ...
Страница 133: ...OUTDOOR UNITS TC 15001 rev 3 2 93 RQWURO 6 VWHP 2 11 1 Refrigerant Cycle HDW 3XPS 7 SH 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 134: ...OUTDOOR UNITS 2 94 TC 15001 rev 3 0RGHO 9 3 6 9 3 6 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 135: ...OUTDOOR UNITS TC 15001 rev 3 2 95 HDW 5HFRYHU 7 SH 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 136: ...OUTDOOR UNITS 2 96 TC 15001 rev 3 0RGHO 9 5 6 9 5 6 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 162: ...OUTDOOR UNITS 2 122 TC 15001 rev 3 ...
Страница 164: ...OUTDOOR UNITS 2 124 TC 15001 rev 3 MODEL H Y VAHP072B41S H Y VAHP096B41S and H Y VAHP120B41S 2 460V 60Hz ...
Страница 166: ...OUTDOOR UNITS 2 126 TC 15001 rev 3 MODEL H Y VAHR072B41S H Y VAHR096B41S and H Y VAHR120B41S 2 460V 60Hz ...
Страница 201: ...INDOOR UNITS TC 15001 rev 3 3 35 3 1 4 10 4 Wiring Diagram DIP DIP DIP DIP DIP Electronic Expansion Valve Ground DIP ...
Страница 217: ...INDOOR UNITS TC 15001 rev 3 3 51 3 1 5 10 4 Wiring Diagram DIP DIP DIP DIP DIP DIP Ground Electronic Expansion Valve ...
Страница 260: ...INDOOR UNITS 3 94 TC 15001 rev 3 TIWM015B21S TIWM018B21S and TIWM024B21S Unit inch mm Electronic Expansion Valve ...
Страница 278: ......
Страница 445: ...CONTROL SYSTEM TC 15001 rev 3 6 129 7 7RXFK DFN WR QLVK WKLV VHWWLQJ The screen returns to the Service Menu screen 7 ...
Страница 463: ...CONTROL SYSTEM TC 15001 rev 3 6 147 9 Touch Back to return to the Service Menu screen 9 ...
Страница 667: ......
Страница 668: ... 2015 Johnson Controls Inc TC 15001 rev 3 Code No LIT 12012244 Revised December 2016 ...