![Johnson Controls HIDH018B21S Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/johnson-controls/hidh018b21s/hidh018b21s_engineering-manual_2023356004.webp)
ii
TC-15001-rev.3
Take the following precautions to reduce the risk of property damage.
Ɣ
Be careful that moisture, dust, or variant refrigerant compounds not enter the refrigerant cycle during
installation work. Foreign matter could damage internal components or cause blockages.
Ɣ
,IDLU¿OWHUVDUHUHTXLUHGRQWKLVXQLWGRQRWRSHUDWHWKHXQLWZLWKRXWWKHDLU¿OWHUVHWLQSODFH,IWKHDLU
¿OWHULVQRWLQVWDOOHGGXVWPD\DFFXPXODWHDQGEUHDNGRZQPD\UHVXOW
Ɣ
Do not install this unit in any place where silicon gases can coalesce. If the silicon gas molecules
DWWDFKWKHPVHOYHVWRWKHVXUIDFHRIWKHKHDWH[FKDQJHUWKH¿QQHGVXUIDFHVZLOOUHSHOZDWHU$VD
UHVXOWDQ\DPRXQWRIGUDLQDJHPRLVWXUHFRQGHQVDWHFDQRYHUÀRZIURPWKHGUDLQFRQGHQVDWHSDQDQG
could run inside of the electrical box, possibly causing electrical failures.
Ɣ
When installing the unit in a hospital or other facility where electromagnetic waves are generated
from nearby medical and/or electronic devices, be prepared for noise and electronic interference
Electromagnetic Interference (EMI). Do not install where the waves can directly radiate into the
electrical box, controller cable, or controller. Inverters, appliances, high-frequency medical equipment,
and radio communications equipment may cause the unit to malfunction. The operation of the unit
may also adversely affect these same devices. Install the unit at least 10 ft. (approximately 3m) away
from such devices.
Ɣ
When a wireless controller is used, locate at a distance of at least 3.3 ft. (approximately 1m) between
WKHLQGRRUXQLWDQGHOHFWULFOLJKWLQJ,IQRWWKHUHFHLYHUSDUWRIWKHXQLWPD\KDYHGLI¿FXOW\UHFHLYLQJ
operation commands.
Ɣ
Do not install the unit in any location where animals and plants can come into direct contact with the
outlet air stream. Exposure could adversely affect the animals and plants.
Ɣ
Do not install the unit with any downward slope to the side of the drain boss. If you do, you may have
GUDLQZDWHUÀRZLQJEDFNZKLFKPD\FDXVHOHDNV
Ɣ
Be sure the drain hose discharges water properly. If connected incorrectly, it may cause leaks.
Ɣ
Do not install the unit in any place where oil can seep onto the units, such as table or seating areas in
restaurants, and so forth. For these locations or social venues, use specialized units with oil-resistant
features built into them. In addition, use a specialized ceiling fan designed for restaurant use. These
specialized oil-resistant units can be ordered for such applications. However, in places where large
quantities of oil can splash onto the unit, such as a factory, even the specialized units cannot be used.
These products should not be installed in such locations.
Ɣ
If the wired controller is installed in a location where electromagnetic radiation is generated, make
sure that the wired controller is shielded and cables are sleeved inside conduit tubing.
Ɣ
If there is a source of electrical interference near the power source, install noise suppression
HTXLSPHQW¿OWHU
Ɣ
'XULQJWKHWHVWUXQFKHFNWKHXQLW¶VRSHUDWLRQWHPSHUDWXUH,IWKHXQLWLVXVHGLQDQHQYLURQPHQW
where the temperature exceeds the operation boundary, it may cause severe damage. Check the
RSHUDWLRQDOWHPSHUDWXUHERXQGDU\LQWKHPDQXDO,IWKHUHLVQRVSHFL¿HGWHPSHUDWXUHXVHWKHXQLW
within the operational temperature boundary of 35 to 104°F (0 to 40°C).
Ɣ
Read installation and appropriate user manuals for connection with PC or peripheral devices. If a
warning window appears on the PC, the product stops, does not work properly or works intermittently,
immediately stop using the equipment.
Содержание HIDH018B21S
Страница 2: ......
Страница 40: ......
Страница 71: ...OUTDOOR UNITS TC 15001 rev 3 2 31 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 72: ...OUTDOOR UNITS 2 32 TC 15001 rev 3 0RGHO 9 3 6 LQFK PP ...
Страница 73: ...OUTDOOR UNITS TC 15001 rev 3 2 33 0RGHO 9 3 6 LQFK PP ...
Страница 74: ...OUTDOOR UNITS 2 34 TC 15001 rev 3 0RGHO 9 3 6 LQFK PP ...
Страница 75: ...OUTDOOR UNITS TC 15001 rev 3 2 35 0RGHO 9 3 6 LQFK PP ...
Страница 76: ...OUTDOOR UNITS 2 36 TC 15001 rev 3 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 77: ...OUTDOOR UNITS TC 15001 rev 3 2 37 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 78: ...OUTDOOR UNITS 2 38 TC 15001 rev 3 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 79: ...OUTDOOR UNITS TC 15001 rev 3 2 39 0RGHO 9 3 0 Ɣ HVV 0RGXOH 7 SH ...
Страница 80: ...OUTDOOR UNITS 2 40 TC 15001 rev 3 0RGHO 9 3 0 DQG 9 3 0 ...
Страница 81: ...OUTDOOR UNITS TC 15001 rev 3 2 41 0RGHO 9 5 6 LQFK PP HDW 5HFRYHU 6 VWHP Ɣ 6WDQGDUG 7 SH ...
Страница 82: ...OUTDOOR UNITS 2 42 TC 15001 rev 3 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 83: ...OUTDOOR UNITS TC 15001 rev 3 2 43 0RGHO 9 5 6 LQFK PP ...
Страница 84: ...OUTDOOR UNITS 2 44 TC 15001 rev 3 0RGHO 9 5 6 LQFK PP ...
Страница 85: ...OUTDOOR UNITS TC 15001 rev 3 2 45 0RGHO 9 5 6 LQFK PP ...
Страница 86: ...OUTDOOR UNITS 2 46 TC 15001 rev 3 0RGHO 9 5 6 LQFK PP ...
Страница 87: ...OUTDOOR UNITS TC 15001 rev 3 2 47 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 88: ...OUTDOOR UNITS 2 48 TC 15001 rev 3 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 89: ...OUTDOOR UNITS TC 15001 rev 3 2 49 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 90: ...OUTDOOR UNITS 2 50 TC 15001 rev 3 0RGHO 9 5 0 Ɣ HVV 0RGXOH 7 SH ...
Страница 91: ...OUTDOOR UNITS TC 15001 rev 3 2 51 0RGHO 9 5 0 DQG 9 5 0 ...
Страница 133: ...OUTDOOR UNITS TC 15001 rev 3 2 93 RQWURO 6 VWHP 2 11 1 Refrigerant Cycle HDW 3XPS 7 SH 0RGHO 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 134: ...OUTDOOR UNITS 2 94 TC 15001 rev 3 0RGHO 9 3 6 9 3 6 9 3 6 DQG 9 3 6 LQFK PP ...
Страница 135: ...OUTDOOR UNITS TC 15001 rev 3 2 95 HDW 5HFRYHU 7 SH 0RGHO 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 136: ...OUTDOOR UNITS 2 96 TC 15001 rev 3 0RGHO 9 5 6 9 5 6 9 5 6 DQG 9 5 6 LQFK PP ...
Страница 162: ...OUTDOOR UNITS 2 122 TC 15001 rev 3 ...
Страница 164: ...OUTDOOR UNITS 2 124 TC 15001 rev 3 MODEL H Y VAHP072B41S H Y VAHP096B41S and H Y VAHP120B41S 2 460V 60Hz ...
Страница 166: ...OUTDOOR UNITS 2 126 TC 15001 rev 3 MODEL H Y VAHR072B41S H Y VAHR096B41S and H Y VAHR120B41S 2 460V 60Hz ...
Страница 201: ...INDOOR UNITS TC 15001 rev 3 3 35 3 1 4 10 4 Wiring Diagram DIP DIP DIP DIP DIP Electronic Expansion Valve Ground DIP ...
Страница 217: ...INDOOR UNITS TC 15001 rev 3 3 51 3 1 5 10 4 Wiring Diagram DIP DIP DIP DIP DIP DIP Ground Electronic Expansion Valve ...
Страница 260: ...INDOOR UNITS 3 94 TC 15001 rev 3 TIWM015B21S TIWM018B21S and TIWM024B21S Unit inch mm Electronic Expansion Valve ...
Страница 278: ......
Страница 445: ...CONTROL SYSTEM TC 15001 rev 3 6 129 7 7RXFK DFN WR QLVK WKLV VHWWLQJ The screen returns to the Service Menu screen 7 ...
Страница 463: ...CONTROL SYSTEM TC 15001 rev 3 6 147 9 Touch Back to return to the Service Menu screen 9 ...
Страница 667: ......
Страница 668: ... 2015 Johnson Controls Inc TC 15001 rev 3 Code No LIT 12012244 Revised December 2016 ...