Johnson Controls Unitary Products

570930-BUM-C-0112

USER’S INFORMATION,

MAINTENANCE AND 

SERVICE MANUAL

DOWNFLOW/UPFLOW

ELECTRIC FURNACE

MODELS: EB

ISO 9001

Certified Quality

Management System

The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.

 

SECTION I: INTRODUCTION

FOR YOUR SAFETY - 

Do not store or use gasoline or other flam-

mable vapors and liquids in the vicinity of this or any other appli-
ance.

For personal safety be sure to turn the electrical power OFF at
the household service box and at the furnace before attempt-
ing any service or maintenance operations. Homeowner
should never perform any maintenance which requires open-
ing the furnace electrical panel.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.

This furnace and its components, including the air conditioning coils
and blowers listed on the A/C accessory sticker were listed in com-
bination as a system by Underwriters Laboratories.
Use of other components not tested in combination with this furnace
may make the equipment in violation of State Codes, may create a
hazard, and may ruin the equipment.
In addition, the National Manufactured Housing Construction and
Safety Standards Act and its Regulations require the use of compo-
nents listed or certified by a nationally recognized testing laboratory
in all manufactured homes built and sold subject to that act.

To avoid the possibility of electrical shock do not open electrical box
panels.

TABLE OF CONTENTS

CONTACT INFORMATION FOR USA  . . . . . . . . . . . . . . . . . . . . . . . 1

CONTACT INFORMATION FOR CANADA   . . . . . . . . . . . . . . . . . . . 1

INTRODUCTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

TO OPERATE FURNACE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

TO SHUT FURNACE OFF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

LIMIT CONTROLS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

BLOWER REMOVAL   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

FURNACE OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

CIRCUIT BREAKERS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

LUBRICATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

BLOWER ASSEMBLY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

AIR FILTER  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

RETURN AIR   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

WHILE YOU’RE AWAY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

AT THE BEGINNING OF EACH HEATING SEASON . . . . . . . . . . . .3

YOUR AUTHORIZED SERVICE TECHNICIAN   . . . . . . . . . . . . . . . .3

OPTIONAL AIR CONDITIONING ACCESSORIES . . . . . . . . . . . . . .3

HIGH PERFORMANCE BLOWER ACCESSORY PACKAGE   . . . . .3

REPAIR PARTS LIST   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

LIMITED WARRANTY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

CONTACT INFORMATION FOR USA

Contact us by mail:

CONTACT INFORMATION FOR CANADA

Go to website at www.york.com click on “contact”, then click on
“contact form” and follow the instructions.

Contact us by mail:

Johnson Controls, Inc.

Consumer Relations

5005 York Drive

Norman, OK 73069

DISTRIBUTED BY:

StyleCrest

801 W. 37th Street

Building #7

Wichita, Ks 67219

MANUFACTURED BY:

Johnson Control, Inc.

5005 York Drive

Norman, OK 73069

Содержание EB

Страница 1: ...on of State Codes may create a hazard and may ruin the equipment In addition the National Manufactured Housing Construction and Safety Standards Act and its Regulations require the use of compo nents listed or certified by a nationally recognized testing laboratory in all manufactured homes built and sold subject to that act To avoid the possibility of electrical shock do not open electrical box p...

Страница 2: ...EAKERS Your electric furnace is equipped with a unique safety feature circuit breakers These circuit breakers are located behind the door of the fur nace near the bottom of the furnace See Figure 1 If a component should fail inside the furnace the circuit breakers will prevent damage that can be caused by an electrical short If the breakers ever trip they can be reset by first turning off the powe...

Страница 3: ...N Your furnace s best friend is your service technician If the unit gives any indication of improper operation call your authorized service tech nician If the service technician is allowed to perform the normal routine care of your furnace many times he can detect potential difficulties and make corrections before trouble develops Preventive maintenance of this type will allow you to operate this ...

Страница 4: ...570930 BUM C 0112 4 Johnson Controls Unitary Products SECTION V REPAIR PARTS LIST 1 24 25 3 4 5 6 26 9 10 11 7 17 16 15 20 21 22 23 12 27 13 14 19 17 18 29 28 1 ...

Страница 5: ...S1 02541238000 4 8Kw 9 6Kw S1 02541237000 S1 02541236000 18 Limit Switch S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 19 Fusible Link S1 02435663000 S1 02435663000 S1 02435663000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 1 Req d S1 3500 377P A Circuit Breaker 2 Req d S1 3500 377P A S1 3500 377P A 22 Buss Bar See N...

Страница 6: ...1240000 2 Ea 9 6Kw S1 02541236000 10 4Kw 11 2Kw S1 02541240000 S1 02541238000 18 Limit Switch S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 19 Fusible Link S1 02435663000 S1 02435663000 S1 02435663000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Req d See Note 2 S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss B...

Страница 7: ...570930 BUM C 0112 Johnson Controls Unitary Products 7 NOTES ...

Страница 8: ...and service instructions 10 Cleaning replacement of filters or any other routine maintenance as set out in the User s Information Maintenance and Service Manual 11 Replacement or cleaning of nozzles or orifices 12 Fuses either internal or external to the product 13 Excessive fuel or electricity consumption THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED ...

Отзывы: