3
2.3 Important Notice:
◆
To
ensure
good performance
and longevity
, the unit must be installed by
certified
t
echnician
s
according
to these instructions
.
2.4 Dimension
s
of Ceiling Opening and Location of
Threaded Mounting Rod
Refrigerant pipe
33"
( Indoor unit)
30-3/4"
(Gaps between hoisting screw
rods)
35"
*(
Ceiling
opening)
37-1/2"
(Decorated
surface board
s)
Threaded mounting
rod
(X4)
33"
( Indoor unit)
35"
(
Ceiling opening)
37-1/2"
(Decorated surface
board
s)
26-3/4"
(Gaps between hoisting screw rods)
Fig.
2 Install
ation
Dimension
s
of Mode
l
DHMW24NKB21S
◆
The drilling
of holes in the ceiling must be done by
certified
technicians.
Ceiling
Installation stands for main body of the unit
(
6-1/4"
)
Above
25/32"
Fig.
3
Note: The dimension
s
for the ceiling openings with * marks can be as large as
3 ft.
(
910mm
)
.
The cassette grille assembly
should
overlap the finished ceiling by at least
13/16 in.
(
20mm
)
.