6
8
Service Manual
Tear off the
adhesive
and then remove the
insulation
.
Remove the
two
screws connecting the isolation
plate and condenser side plate; remove the
three
screws connecting the isolation plate and chassis,
and then remove the isolation plate.
Unsolder the welding joints connecting the 4-way
valve assy with capillary sub-assy, compressor and
condenser; remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
Steps
Procedure
8. Remove
4-way valve assy
7. Remove isolation plate
6. Remove the
insulation
insulation
isolation plate
4-way valve assy
Содержание DCX18CSB21S
Страница 51: ...43 ...
Страница 54: ...46 3 Malfunction of Protection of Jumper Cap C5 ...
Страница 72: ...64 Service Manual ...