4
5
Service Manual
8
. Removal Procedure
s
refrigerant completely before removal.
8
.1 Removal Procedure
s
of Indoor Unit
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
a
b
Axile bush
Push out the axile bush on horizontal
louver. Bend the horizontal louver
by
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
Horizontal louver
Location of step motor
Procedure
Step
1. Remove filter assembly
2. Remove horizontal louver
Front panel
Front
case
Right filter
Groove
Left filter
Open the front panel. Push the left filter
and right filter until they are separate from
the groove on the front panel.
Remove the left filter and right filter
respectively.
(1)A1/A5/C2 panel display: Screw off
the 2 screws that are locking the display
board. Separate the display board from
the front panel.
(2)A5/A6 panel display: Screw off the 2
screws that are locking the display board.
Note:This display can be disassembled
only after removing the front case (refer to
step 5 of disassembly).
(3)B2/B4/B8 panel display: Screw off
the 2 screws that are locking the display
board.
Separate the panel rotation shaft from
the groove fixing the front panel and then
remove the front panel.
3. Remove panel
Panel
Screws
A5/A6 display
A1/A5/C2 display
B2/B4/B8 display
Front panel
Panel rotation
Groove
NOTE: Take A6 panel
as
an example.